title: "Giant GHPCO-45 1**+GXST-50TTTP 1** (3.52 UEF, 45 gal)"
url: https://gcsradheat.com/water-heaters/giant/ghpco-45-1-gxst-50tttp-1/
description: "In the 706-unit Hybrid/Electric Heat Pump class, Giant GHPCO-45 1**+GXST-50TTTP 1** (Electric) achieves a certified 3.52 UEF rating across its 45-gallon."
---

ENERGY STAR water heater model · PD 4529414

# Giant GHPCO-45 1**+GXST-50TTTP 1** Water Heater Specifications (3.52 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Giant GHPCO-45 1**+GXST-50TTTP 1** (Electric) achieves a certified 3.52 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating (rank #441 of 706, PD 4529414) and verifies as Pass: +1.22 / +53.0% for 2029 DOE floors. Rated annual electricity draw of 923 kWh/yr equates to roughly $168/yr ($1,676 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF).

- **Uniform Energy Factor**: 3.52 UEF

- **Cohort UEF Rank**: #441 of 706

- **First Hour Rating**: 67 gal

- **Storage Volume**: 45 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.22 / +53.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Giant GHPCO-45 1**+GXST-50TTTP 1** relative to the cohort median.

Efficiency comparison & rule summary

Giant GHPCO-45 1**+GXST-50TTTP 1** records 3.52 UEF efficiency, putting it #441 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Giant GHPCO-45 1**+GXST-50TTTP 1** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.22 UEF (+53.0%). At EIA August 2026 national rates (18.16 cents/kWh), 923 kWh/yr for Giant GHPCO-45 1**+GXST-50TTTP 1** runs ~$168/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Giant GHPCO-45 1**+GXST-50TTTP 1**: 10-year operating spend spans $1,350 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,355 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Giant GHPCO-45 1**+GXST-50TTTP 1** (3.52 UEF) are A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF, at parity) and American MHPCO-45 1**+MXST-50T 1** (3.52 UEF, at parity).

## What Physical and Thermal Ratings Define Giant GHPCO-45 1**+GXST-50TTTP 1**?

Positioning at #441 of 706 out of 706 Hybrid/Electric Heat Pump peers, Giant GHPCO-45 1**+GXST-50TTTP 1** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Giant](https://gcsradheat.com/brands/giant/) | 12 certified listings | ENERGY STAR PD 4529414 |
| Model Number | GHPCO-45 1**+GXST-50TTTP 1** | Draw pattern: Medium-Usage | GHPCO-45 1**+GXST-50TTTP 1** |
| Uniform Energy Factor (UEF) | 3.52 | -0.18 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 923 kWh/yr | -149 kWh/yr vs. 1,072 kWh/yr median | Est. $168/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 413% | -16.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 57" H x 16" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 20.2 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 / Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-03-24 | Certified 2026-03-24 | Markets: Canada |

## Why Do State Utility Rates Shift GHPCO-45 1**+GXST-50TTTP 1** Running Costs?

Consuming 923 kWh annually puts Giant GHPCO-45 1**+GXST-50TTTP 1** near $168/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $168/yr | $1,676 | $4,736 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $435/yr | $4,355 | $12,305 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $275/yr | $2,746 | $7,759 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $147/yr | $1,468 | $4,149 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $135/yr | $1,350 | $3,816 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (923 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any Giant Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Giant; confirm tank age separately using the rating-plate serial pattern. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## What Are 5 Direct Alternatives to Giant GHPCO-45 1**+GXST-50TTTP 1**?

Homeowners cross-shopping Giant GHPCO-45 1**+GXST-50TTTP 1** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith HPACO-45 1**+AXST-50T 1**](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-50t-1/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (at parity) | 923 |
| [American MHPCO-45 1**+MXST-50T 1**](https://gcsradheat.com/water-heaters/american/mhpco-45-1-mxst-50t-1/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (at parity) | 923 |
| [GSW WATER HEATERS GTHPCO-45 1**+GTXST-50T 1**](https://gcsradheat.com/water-heaters/gsw-water-heaters/gthpco-45-1-gtxst-50t-1/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (at parity) | 923 |
| [John Wood JWHPCO-45 1**+JWXST-50T 1**](https://gcsradheat.com/water-heaters/john-wood/jwhpco-45-1-jwxst-50t-1/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (at parity) | 923 |
| [A. O. Smith HPACO-45 1**+AXST-50TTTP 1**](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-50tttp-1/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (at parity) | 923 |

## What Are the Limitations of Giant GHPCO-45 1**+GXST-50TTTP 1** and Who Should Not Install It?

Before ordering Giant GHPCO-45 1**+GXST-50TTTP 1** (Hybrid/Electric Heat Pump, 3.52 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- Giant GHPCO-45 1**+GXST-50TTTP 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Giant GHPCO-45 1**+GXST-50TTTP 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Giant GHPCO-45 1**+GXST-50TTTP 1 Strong Fit — 3.52 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-50T 1** footprint.

## Sizing, Efficiency & Recall Answers for Giant GHPCO-45 1**+GXST-50TTTP 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Giant GHPCO-45 1**+GXST-50TTTP 1** pass the May 6, 2029 federal DOE efficiency rule?

Giant GHPCO-45 1**+GXST-50TTTP 1** carries a verified 3.52 UEF rating (Pass: +1.22 / +53.0%), ranking #441 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

### What doorway width and ceiling height does Giant GHPCO-45 1**+GXST-50TTTP 1** need?

Giant GHPCO-45 1**+GXST-50TTTP 1** stands 57 in. high with a 16 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (16" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does Giant GHPCO-45 1**+GXST-50TTTP 1** require?

Giant GHPCO-45 1**+GXST-50TTTP 1** uses a 240V branch circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

### How much electricity or energy does Giant GHPCO-45 1**+GXST-50TTTP 1** cost per year to run?

Rated at 923 kWh/yr, Giant GHPCO-45 1**+GXST-50TTTP 1** costs about $168/yr ($1,680 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $135/yr in Washington hydro tiers up to $435/yr in Hawaii).

### Who should NOT install Giant GHPCO-45 1**+GXST-50TTTP 1**, and what are its limits?

Giant GHPCO-45 1**+GXST-50TTTP 1** (3.52 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

### How many bathrooms or people can Giant GHPCO-45 1**+GXST-50TTTP 1** serve at peak demand?

Giant GHPCO-45 1**+GXST-50TTTP 1** achieves a 67 gal First Hour Rating (-5 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for Giant GHPCO-45 1**+GXST-50TTTP 1**?

No active CPSC recalls matched Giant as of 2026-11-23. Always decode the serial tag on Giant GHPCO-45 1**+GXST-50TTTP 1** because OEM tank/exchanger warranties span 6–12 years.

### What 2026 rebates apply to Giant GHPCO-45 1**+GXST-50TTTP 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF).

## Related Rebate, Gas-Line & Serial Tools for GHPCO-45 1**+GXST-50TTTP 1**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith HPACO-45 1**+AXST-50T 1** (3.52 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-50t-1/)
- [Compare American MHPCO-45 1**+MXST-50T 1** (3.52 UEF)→](https://gcsradheat.com/water-heaters/american/mhpco-45-1-mxst-50t-1/)
- [View All Giant Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/giant/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)