---
title: "Giant GTHPCO-45 1**+GTXST-50LBTTP 1* (3.55 UEF, 48 gal)"
url: https://gcsradheat.com/water-heaters/giant/gthpco-45-1-gtxst-50lbttp-1/
description: "In the 706-unit Hybrid/Electric Heat Pump class, Giant GTHPCO-45 1**+GTXST-50LBTTP 1* (Electric) achieves a certified 3.55 UEF rating across its 48-gallon."
---

ENERGY STAR water heater model · PD 4529614

# Giant GTHPCO-45 1**+GTXST-50LBTTP 1* Water Heater Specifications (3.55 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Giant GTHPCO-45 1**+GTXST-50LBTTP 1* (Electric) achieves a certified 3.55 UEF rating across its 48-gallon nominal tank, 72 gal First Hour Rating (rank #414 of 706, PD 4529614) and verifies as Pass: +1.25 / +54.3% for 2029 DOE floors. Rated annual electricity draw of 915 kWh/yr equates to roughly $166/yr ($1,662 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF).

- **Uniform Energy Factor**: 3.55 UEF

- **Cohort UEF Rank**: #414 of 706

- **First Hour Rating**: 72 gal

- **Storage Volume**: 48 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.25 / +54.3%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Giant GTHPCO-45 1**+GTXST-50LBTTP 1* relative to the cohort median.

Efficiency comparison & rule summary

Giant GTHPCO-45 1**+GTXST-50LBTTP 1* records 3.55 UEF efficiency, putting it #414 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Giant GTHPCO-45 1**+GTXST-50LBTTP 1* exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.25 UEF (+54.3%). At EIA August 2026 national rates (18.16 cents/kWh), 915 kWh/yr for Giant GTHPCO-45 1**+GTXST-50LBTTP 1* runs ~$166/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Giant GTHPCO-45 1**+GTXST-50LBTTP 1*: 10-year operating spend spans $1,339 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,317 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Giant GTHPCO-45 1**+GTXST-50LBTTP 1* (3.55 UEF) are A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF, at parity) and American MHPCO-45 1**+MXST-50LBTTP 1** (3.55 UEF, at parity).

## Which Specs Set Giant GTHPCO-45 1**+GTXST-50LBTTP 1* Apart From Cohort Averages?

Ranked #414 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Giant GTHPCO-45 1**+GTXST-50LBTTP 1* is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Giant](https://gcsradheat.com/brands/giant/) | 12 certified listings | ENERGY STAR PD 4529614 |
| Model Number | GTHPCO-45 1**+GTXST-50LBTTP 1* | Draw pattern: Medium-Usage | GTHPCO-45 1**+GTXST-50LBTTP 1* |
| Uniform Energy Factor (UEF) | 3.55 | -0.15 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 72 gal | At 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 915 kWh/yr | -157 kWh/yr vs. 1,072 kWh/yr median | Est. $166/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 428% | -1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 33" H x 22.5" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 20.2 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 / Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-03-24 | Certified 2026-03-24 | Markets: United States, Canada |

## How Do Regional kWh Prices Impact GTHPCO-45 1**+GTXST-50LBTTP 1* Over 10 Years?

Using EIA Table 5.6.A benchmarks, Giant GTHPCO-45 1**+GTXST-50LBTTP 1*'s 915 kWh/yr draw translates to roughly $166/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $166/yr | $1,662 | $4,751 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $432/yr | $4,317 | $12,342 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $272/yr | $2,722 | $7,783 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $146/yr | $1,456 | $4,162 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $134/yr | $1,339 | $3,827 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (915 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should Giant Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Giant; run a quick serial-number check to verify age before replacing wear parts. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith HPACO-45 1**+AXST-50LBTTP 1**](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-50lbttp-1/) | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (at parity) | 915 |
| [American MHPCO-45 1**+MXST-50LBTTP 1**](https://gcsradheat.com/water-heaters/american/mhpco-45-1-mxst-50lbttp-1/) | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (at parity) | 915 |
| [GSW WATER HEATERS GHPCO-45 1**+GXST-50LBTTP 1**](https://gcsradheat.com/water-heaters/gsw-water-heaters/ghpco-45-1-gxst-50lbttp-1/) | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (at parity) | 915 |
| [John Wood JWHPCO-45 1**+JWXST-50LBTTP 1*](https://gcsradheat.com/water-heaters/john-wood/jwhpco-45-1-jwxst-50lbttp-1/) | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (at parity) | 915 |
| [A. O. Smith HPACO-45C 1**+AXST-50LBCTTP 1*](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45c-1-axst-50lbcttp-1/) | Hybrid/Electric Heat Pump | 48 gal | 72 gal | 3.55 (at parity) | 915 |

## Which Home Setups Are NOT a Fit for Giant GTHPCO-45 1**+GTXST-50LBTTP 1*?

Comparing Giant GTHPCO-45 1**+GTXST-50LBTTP 1* against A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- Giant GTHPCO-45 1**+GTXST-50LBTTP 1* needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Giant GTHPCO-45 1**+GTXST-50LBTTP 1* directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Giant GTHPCO-45 1**+GTXST-50LBTTP 1*** Strong Fit — 3.55 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** footprint.

## Frequently Asked Technical Questions: Giant GTHPCO-45 1**+GTXST-50LBTTP 1*

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Giant GTHPCO-45 1**+GTXST-50LBTTP 1* score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Giant GTHPCO-45 1**+GTXST-50LBTTP 1* logs 3.55 UEF (Pass: +1.25 / +54.3%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing Giant GTHPCO-45 1**+GTXST-50LBTTP 1*?

With a 33 in. height and 22.5 in. diameter, Giant GTHPCO-45 1**+GTXST-50LBTTP 1* fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits Giant GTHPCO-45 1**+GTXST-50LBTTP 1*?

Powered via 240V at 20.2A max, Giant GTHPCO-45 1**+GTXST-50LBTTP 1* requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for Giant GTHPCO-45 1**+GTXST-50LBTTP 1*?

Annual electric spend for Giant GTHPCO-45 1**+GTXST-50LBTTP 1* (915 kWh/yr) averages $166/yr nationwide (ranging from $134/yr in Washington hydro tiers up to $432/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing Giant GTHPCO-45 1**+GTXST-50LBTTP 1*?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Giant GTHPCO-45 1**+GTXST-50LBTTP 1*.

### Is Giant GTHPCO-45 1**+GTXST-50LBTTP 1* sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Giant GTHPCO-45 1**+GTXST-50LBTTP 1* at 72 gal First Hour Rating (At 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does Giant have active CPSC SaferProducts notices affecting GTHPCO-45 1**+GTXST-50LBTTP 1*?

Zero CPSC recall alerts matched Giant (2026-11-23 check). Keep your Giant GTHPCO-45 1**+GTXST-50LBTTP 1* serial code handy to track standard 6-to-12-year OEM warranty coverage.

### Which competing water heater matches Giant GTHPCO-45 1**+GTXST-50LBTTP 1* (3.55 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Giant GTHPCO-45 1**+GTXST-50LBTTP 1*. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF).

## Essential Pre-Install Guides for Giant GTHPCO-45 1**+GTXST-50LBTTP 1*

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-50lbttp-1/)
- [Compare American MHPCO-45 1**+MXST-50LBTTP 1** (3.55 UEF)→](https://gcsradheat.com/water-heaters/american/mhpco-45-1-mxst-50lbttp-1/)
- [View All Giant Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/giant/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)
