# GREENoneTEC Double GT Water Heater Specifications (6.7 SUEF)

Engineered as a Natural Gas Solar with Gas Backup unit, GREENoneTEC Double GT achieves a certified 6.7 SUEF rating across its 51-gallon nominal tank and ranks #19 of 25 in its 25-model cohort (PD 2408187), recording Exempt — Solar SUEF under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is SunEarth C2-40T-50-TLG (5.2 SUEF).

- **Solar UEF (SUEF)**: 6.7 SUEF

- **Cohort SUEF Rank**: #19 of 25

- **First Hour Rating**: On-Demand

- **Storage Volume**: 51 gal

- **Fuel / Type**: Natural Gas / Solar with Gas Backup

- **DOE 2029 Rule Status**: Exempt — Solar SUEF

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Solar with Gas Backup SUEF Efficiency Distribution (25 Certified Units). Highlighted pin shows GREENoneTEC Double GT relative to the cohort median.

Efficiency comparison & rule summary

Within the 25-unit Solar with Gas Backup cohort, GREENoneTEC Double GT logs 6.7 SUEF and ranks #19 of 25.

Solar collector & storage profile, OG-300 #30004323 for GREENoneTEC Double GT: Direct ICS architecture; 44.6 sq ft Batch collector; 51 gal storage tank; freeze limit 19 deg F.

Cross-shopping GREENoneTEC Double GT (6.7 SUEF)? Check SunEarth C2-40T-50-TLG (5.2 SUEF, delta -1.50) and SAMMLER A208 (99.0 SUEF, delta +92.30).

## What Physical and Thermal Ratings Define GREENoneTEC Double GT?

Positioning at #19 of 25 out of 25 Solar with Gas Backup peers, GREENoneTEC Double GT pairs measured SUEF performance with specific clearance and wiring rules.

Certified model attributes compared against 25 ENERGY STAR Solar with Gas Backup peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [GREENoneTEC](https://gcsradheat.com/brands/greenonetec/) | 6 certified listings | ENERGY STAR PD 2408187 |
| Model Number | Double GT | Draw pattern: Medium-Usage | Double GT |
| Solar Uniform Energy Factor (SUEF) | 6.7 | -77.80 SUEF vs. 84.50 SUEF median | 10 CFR 430 Test Method |
| Solar System & Collector | Direct ICS (Batch) | 44.6 sq ft aperture | OG-300 #30004323 |
| Collector Freeze Tolerance | 19 °F | SRCC freeze protection rating | ENERGY STAR Solar Dataset |
| Certification Date | 2022-03-20 | Certified 2022-03-20 | Markets: United States |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any GREENoneTEC Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for GREENoneTEC; confirm tank age separately using the rating-plate serial pattern. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## What Are 5 Direct Alternatives to GREENoneTEC Double GT?

Homeowners cross-shopping GREENoneTEC Double GT frequently review these five Solar with Gas Backup models ranked closest on capacity and SUEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | SUEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [SunEarth C2-40T-50-TLG](https://gcsradheat.com/water-heaters/sunearth/c2-40t-50-tlg/) | Solar with Gas Backup | 50 gal | — | 5.2 (-1.50) | — |
| [SAMMLER A208](https://gcsradheat.com/water-heaters/sammler/a208/) | Solar with Gas Backup | 53 gal | — | 99.0 (+92.30) | — |
| [Solahart ASTG 181J](https://gcsradheat.com/water-heaters/solahart/astg-181j/) | Solar with Gas Backup | 48 gal | — | 99.0 (+92.30) | — |
| [Heliodyne HPAK 1 406 GT 65 ACD Z](https://gcsradheat.com/water-heaters/heliodyne/hpak-1-406-gt-65-acd-z/) | Solar with Gas Backup | 65 gal | — | 99.0 (+92.30) | — |
| [SAMMLER A228](https://gcsradheat.com/water-heaters/sammler/a228/) | Solar with Gas Backup | 53 gal | — | 99.0 (+92.30) | — |

## Who Is GREENoneTEC Double GT Best For — and When Should You Pick SunEarth C2-40T-50-TLG?

Evaluate whether GREENoneTEC Double GT's Solar with Gas Backup architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- GREENoneTEC Double GT logs 6.7 SUEF (Exempt — Solar SUEF); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect GREENoneTEC Double GT's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 51 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for GREENoneTEC Double GT** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like SunEarth C2-40T-50-TLG.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Sizing, Efficiency & Recall Answers for GREENoneTEC Double GT

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does GREENoneTEC Double GT (6.7 SUEF) compare to 2029 federal DOE floors?

Because GREENoneTEC Double GT harvests solar thermal energy (6.7 SUEF), federal 10 CFR 430.32 tank minimums do not restrict its sale in 2029 or beyond.

### Does GREENoneTEC Double GT fit inside a tight hallway closet or low-headroom utility room?

Designed as a compact solar with gas backup platform (wall-hung / compact envelope), GREENoneTEC Double GT still needs code-compliant flue separation from windows and gas meters.

### What power supply or fuel line specs govern GREENoneTEC Double GT?

Installing GREENoneTEC Double GT on Natural Gas involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.

### What annual utility bill should homeowners budget for GREENoneTEC Double GT?

Rated 6.7 SUEF on Natural Gas, GREENoneTEC Double GT carries no whole-house kWh heating draw; confirm annual therm usage against 25 Solar with Gas Backup models.

### What are the main drawbacks of GREENoneTEC Double GT (6.7 SUEF)?

Buyers expecting endless simultaneous shower flow beyond 51 gal should compare condensing tankless units or larger-capacity tanks.

### What hot-water delivery rating governs GREENoneTEC Double GT?

On-demand Solar with Gas Backup sizing for GREENoneTEC Double GT depends on winter inlet water temp (typically 45–65 °F) heated to a 120 °F anti-scald setpoint.

### Where do homeowners screen GREENoneTEC Double GT for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for GREENoneTEC; use our browser-only serial decoder to inspect GREENoneTEC Double GT's age and warranty window.

### What alternative models sit closest to GREENoneTEC Double GT in the Solar with Gas Backup class?

Closest peer in Solar with Gas Backup is SunEarth C2-40T-50-TLG (5.2 SUEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Related Rebate, Gas-Line & Serial Tools for Double GT

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare SunEarth C2-40T-50-TLG (5.2 SUEF)→](https://gcsradheat.com/water-heaters/sunearth/c2-40t-50-tlg/)
- [Compare SAMMLER A208 (99.0 SUEF)→](https://gcsradheat.com/water-heaters/sammler/a208/)
- [View All GREENoneTEC Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/greenonetec/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)