title: "GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** (3.8 UEF, 73 gal)"
url: https://gcsradheat.com/water-heaters/gsw-water-heaters/ghpco-45-1-gxst-80ttp-1/
description: "In the 706-unit Hybrid/Electric Heat Pump class, GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** (Electric) achieves a certified 3.8 UEF rating across its."
---

ENERGY STAR water heater model · PD 4529399

# GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** Water Heater Specifications (3.8 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** (Electric) achieves a certified 3.8 UEF rating across its 73-gallon nominal tank, 95 gal First Hour Rating (rank #268 of 706, PD 4529399) and verifies as Pass: +1.30 / +52.0% for 2029 DOE floors. Rated annual electricity draw of 1,306 kWh/yr equates to roughly $237/yr ($2,372 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF).

- **Uniform Energy Factor**: 3.8 UEF

- **Cohort UEF Rank**: #268 of 706 (top 41.9%)

- **First Hour Rating**: 95 gal

- **Storage Volume**: 73 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.30 / +52.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** relative to the cohort median.

Efficiency comparison & rule summary

GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** records 3.8 UEF efficiency, putting it #268 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.30 UEF (+52.0%). At EIA August 2026 national rates (18.16 cents/kWh), 1,306 kWh/yr for GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** runs ~$237/yr vs. ~$980/yr for a 0.92 UEF electric tank.

State electric sensitivity for GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1**: 10-year operating spend spans $1,911 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,162 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** (3.8 UEF) are A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF, at parity) and American MHPCO-45 1**+MXST-80 1** (3.8 UEF, at parity).

## Which Specs Set GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** Apart From Cohort Averages?

Ranked #268 of 706 (top 41.9%) inside the 706-model Hybrid/Electric Heat Pump cohort, GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [GSW WATER HEATERS](https://gcsradheat.com/brands/gsw-water-heaters/) | 33 certified listings | ENERGY STAR PD 4529399 |
| Model Number | GHPCO-45 1**+GXST-80TTP 1** | Draw pattern: High-Usage | GHPCO-45 1**+GXST-80TTP 1** |
| Uniform Energy Factor (UEF) | 3.8 | +0.10 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 95 gal | +23 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,306 kWh/yr | +234 kWh/yr vs. 1,072 kWh/yr median | Est. $237/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 423% | -6.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 58" H x 20" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 20.2 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 / Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-03-19 | Certified 2026-03-19 | Markets: United States, Canada |

## How Do Regional kWh Prices Impact GHPCO-45 1**+GXST-80TTP 1** Over 10 Years?

Using EIA Table 5.6.A benchmarks, GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1**'s 1,306 kWh/yr draw translates to roughly $237/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $237/yr | $2,372 | $7,424 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $616/yr | $6,162 | $19,287 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $389/yr | $3,885 | $12,162 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $208/yr | $2,078 | $6,504 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $191/yr | $1,911 | $5,981 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,306 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should GSW WATER HEATERS Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for GSW WATER HEATERS; run a quick serial-number check to verify age before replacing wear parts. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith HPACO-45 1**+AXST-80 1**](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-80-1/) | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
| [American MHPCO-45 1**+MXST-80 1**](https://gcsradheat.com/water-heaters/american/mhpco-45-1-mxst-80-1/) | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
| [Giant GTHPCO-45 1**+GTXST-80 1**](https://gcsradheat.com/water-heaters/giant/gthpco-45-1-gtxst-80-1/) | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
| [John Wood JWHPCO-45 1**+JWXST-80 1**](https://gcsradheat.com/water-heaters/john-wood/jwhpco-45-1-jwxst-80-1/) | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |
| [A. O. Smith HPACO-45 1**+AXST-80TTP 1**](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-80ttp-1/) | Hybrid/Electric Heat Pump | 73 gal | 95 gal | 3.8 (at parity) | 1,306 |

## What Installation Caveats Apply Before Buying GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1**?

Even high-UEF units like GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** (3.8 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1 Strong Fit — 3.8 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-80 1** footprint.

## Frequently Asked Technical Questions: GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** eligible for continued manufacture past May 6, 2029?

At 3.8 UEF, GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** achieves Pass: +1.30 / +52.0% for the 2029 DOE standard and stands #268 of 706 (top 41.9%) against A. O. Smith HPACO-45 1**+AXST-80 1** and American MHPCO-45 1**+MXST-80 1**.

### How tall and wide is GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1**, and what service clearance is needed?

Physical dimensions for GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** are 58 in. height and 20 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20" d)); verify stair turns and drain pan width before delivery.

### Will GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** require upgrading household electrical panels or gas piping?

GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** draws 240V at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $237/yr ($2,370 over 10 years) to power GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** at 1,306 kWh/yr under the 18.16 cents/kWh US average (ranging from $191/yr in Washington hydro tiers up to $616/yr in Hawaii).

### Which installation bottlenecks limit GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1**?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** drops into resistance mode more often.

### How does GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** handle simultaneous showers and laundry?

Delivering 95 gal in the first hour (+23 gal vs. 72 gal median), GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** combines 73 gal tank storage with rapid burner/element recovery.

### How long is the warranty on GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** and how do you decode its serial?

CPSC records show 0 active plumbing recalls for GSW WATER HEATERS as of 2026-11-23. Confirm install proof and serial manufacture year on GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1** before calling service.

### How do 2026 post-OBBBA rebates affect buying GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1**?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF).

## Essential Pre-Install Guides for GSW WATER HEATERS GHPCO-45 1**+GXST-80TTP 1**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith HPACO-45 1**+AXST-80 1** (3.8 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-80-1/)
- [Compare American MHPCO-45 1**+MXST-80 1** (3.8 UEF)→](https://gcsradheat.com/water-heaters/american/mhpco-45-1-mxst-80-1/)
- [View All GSW WATER HEATERS Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/gsw-water-heaters/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)