title: "Heliodyne HF 1 406 G 40 AC S E (3.3 SUEF, 40 gal)"
url: https://gcsradheat.com/water-heaters/heliodyne/hf-1-406-g-40-ac-s-e/
description: "With PD 2421038 certification, Heliodyne HF 1 406 G 40 AC S E (Solar with Electric Backup, Solar + Electric Backup) achieves a certified 3.3 SUEF rating across."
---

ENERGY STAR water heater model · PD 2421038

# Heliodyne HF 1 406 G 40 AC S E Water Heater Specifications (3.3 SUEF)

With PD 2421038 certification, Heliodyne HF 1 406 G 40 AC S E (Solar with Electric Backup, Solar + Electric Backup) achieves a certified 3.3 SUEF rating across its 40-gallon nominal tank, standing #28 of 30 across 30 peers with Exempt — Solar SUEF for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is GREENoneTEC HE (11.0 SUEF).

- **Solar UEF (SUEF)**: 3.3 SUEF

- **Cohort SUEF Rank**: #28 of 30

- **First Hour Rating**: On-Demand

- **Storage Volume**: 40 gal

- **Fuel / Type**: Solar + Electric Backup / Solar with Electric Backup

- **DOE 2029 Rule Status**: Exempt — Solar SUEF

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Solar with Electric Backup SUEF Efficiency Distribution (30 Certified Units). Highlighted pin shows Heliodyne HF 1 406 G 40 AC S E relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places Heliodyne HF 1 406 G 40 AC S E at 3.3 SUEF (#28 of 30; -7.55 SUEF vs. 10.85 SUEF median) in Solar with Electric Backup.

Solar collector & storage profile, OG-300 #30004352 for Heliodyne HF 1 406 G 40 AC S E: Direct Forced Circulation architecture; 27 sq ft Flat Plate collector; 40 gal storage tank; freeze limit 27 deg F.

In the Solar with Electric Backup tier, GREENoneTEC HE (11.0 SUEF, delta +7.70) and Solahart 181BTC (99.0 SUEF, delta +95.70) bracket Heliodyne HF 1 406 G 40 AC S E.

## What Physical and Thermal Ratings Define Heliodyne HF 1 406 G 40 AC S E?

Positioning at #28 of 30 out of 30 Solar with Electric Backup peers, Heliodyne HF 1 406 G 40 AC S E pairs measured SUEF performance with specific clearance and wiring rules.

Certified model attributes compared against 30 ENERGY STAR Solar with Electric Backup peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Heliodyne](https://gcsradheat.com/brands/heliodyne/) | 6 certified listings | ENERGY STAR PD 2421038 |
| Model Number | HF 1 406 G 40 AC S E | Draw pattern: Low-Usage | HF 1 406 G 40 AC S E |
| Solar Uniform Energy Factor (SUEF) | 3.3 | -7.55 SUEF vs. 10.85 SUEF median | 10 CFR 430 Test Method |
| Solar System & Collector | Direct Forced Circulation (Flat Plate) | 27 sq ft aperture | OG-300 #30004352 |
| Collector Freeze Tolerance | 27 °F | SRCC freeze protection rating | ENERGY STAR Solar Dataset |
| Electrical Circuit Requirements | 240 V | Collector loop pump / controller + backup element check | NEC / Branch circuit check |
| Certification Date | 2020-11-13 | Certified 2020-11-13 | Markets: United States |

## Have Any Heliodyne Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Heliodyne; confirm tank age separately using the rating-plate serial pattern. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## What Are 5 Direct Alternatives to Heliodyne HF 1 406 G 40 AC S E?

Homeowners cross-shopping Heliodyne HF 1 406 G 40 AC S E frequently review these five Solar with Electric Backup models ranked closest on capacity and SUEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | SUEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [GREENoneTEC HE](https://gcsradheat.com/water-heaters/greenonetec/he/) | Solar with Electric Backup | 40 gal | — | 11.0 (+7.70) | — |
| [Solahart 181BTC](https://gcsradheat.com/water-heaters/solahart/181btc/) | Solar with Electric Backup | 48 gal | — | 99.0 (+95.70) | — |
| [AET FF-80-42](https://gcsradheat.com/water-heaters/aet/ff-80-42/) | Solar with Electric Backup | 50 gal | — | 6.7 (+3.40) | — |
| [Dimas 300-2](https://gcsradheat.com/water-heaters/dimas/300-2/) | Solar with Electric Backup | 79 gal | — | 99.0 (+95.70) | — |
| [Solahart 181BTC Free Heat](https://gcsradheat.com/water-heaters/solahart/181btc-free-heat/) | Solar with Electric Backup | 48 gal | — | 99.0 (+95.70) | — |

## Who Is Heliodyne HF 1 406 G 40 AC S E Best For — and When Should You Pick GREENoneTEC HE?

Evaluate whether Heliodyne HF 1 406 G 40 AC S E's Solar with Electric Backup architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- Heliodyne HF 1 406 G 40 AC S E logs 3.3 SUEF (Exempt — Solar SUEF); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect Heliodyne HF 1 406 G 40 AC S E's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 40 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for Heliodyne HF 1 406 G 40 AC S E** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like GREENoneTEC HE.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Sizing, Efficiency & Recall Answers for Heliodyne HF 1 406 G 40 AC S E

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Heliodyne HF 1 406 G 40 AC S E (3.3 SUEF) compare to 2029 federal DOE floors?

Because Heliodyne HF 1 406 G 40 AC S E harvests solar thermal energy (3.3 SUEF), federal 10 CFR 430.32 tank minimums do not restrict its sale in 2029 or beyond.

### Does Heliodyne HF 1 406 G 40 AC S E fit inside a tight hallway closet or low-headroom utility room?

Designed as a compact solar with electric backup platform (wall-hung / compact envelope), Heliodyne HF 1 406 G 40 AC S E still needs code-compliant flue separation from windows and gas meters.

### What power supply or fuel line specs govern Heliodyne HF 1 406 G 40 AC S E?

For Heliodyne HF 1 406 G 40 AC S E, plan a 240V circuit (Collector loop pump / controller + backup element check) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for Heliodyne HF 1 406 G 40 AC S E?

Rated 3.3 SUEF on Solar + Electric Backup, Heliodyne HF 1 406 G 40 AC S E carries no whole-house kWh heating draw; confirm annual therm usage against 30 Solar with Electric Backup models.

### What are the main drawbacks of Heliodyne HF 1 406 G 40 AC S E (3.3 SUEF)?

Buyers expecting endless simultaneous shower flow beyond 40 gal should compare condensing tankless units or larger-capacity tanks.

### What hot-water delivery rating governs Heliodyne HF 1 406 G 40 AC S E?

On-demand Solar with Electric Backup sizing for Heliodyne HF 1 406 G 40 AC S E depends on winter inlet water temp (typically 45–65 °F) heated to a 120 °F anti-scald setpoint.

### Where do homeowners screen Heliodyne HF 1 406 G 40 AC S E for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Heliodyne; use our browser-only serial decoder to inspect Heliodyne HF 1 406 G 40 AC S E's age and warranty window.

### What alternative models sit closest to Heliodyne HF 1 406 G 40 AC S E in the Solar with Electric Backup class?

Closest peer in Solar with Electric Backup is GREENoneTEC HE (11.0 SUEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Related Rebate, Gas-Line & Serial Tools for HF 1 406 G 40 AC S E

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare GREENoneTEC HE (11.0 SUEF)→](https://gcsradheat.com/water-heaters/greenonetec/he/)
- [Compare Solahart 181BTC (99.0 SUEF)→](https://gcsradheat.com/water-heaters/solahart/181btc/)
- [View All Heliodyne Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/heliodyne/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Check SRCC collector freeze protection, backup tank wiring, and available post-OBBBA state DOE HEAR / utility solar incentives before replacement.
[Check 2026 State Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Model Replacement Labor](https://gcsradheat.com/costs/water-heater-replacement/)