# Heliodyne HF 1 408 G 60 AC S E Water Heater Specifications (10.7 SUEF)

Engineered as a Solar + Electric Backup Solar with Electric Backup unit, Heliodyne HF 1 408 G 60 AC S E achieves a certified 10.7 SUEF rating across its 60-gallon nominal tank and ranks #16 of 30 in its 30-model cohort (PD 2421037), recording Exempt — Solar SUEF under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is GREENoneTEC Double E (3.3 SUEF).

- **Solar UEF (SUEF)**: 10.7 SUEF

- **Cohort SUEF Rank**: #16 of 30

- **First Hour Rating**: On-Demand

- **Storage Volume**: 60 gal

- **Fuel / Type**: Solar + Electric Backup / Solar with Electric Backup

- **DOE 2029 Rule Status**: Exempt — Solar SUEF

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Solar with Electric Backup SUEF Efficiency Distribution (30 Certified Units). Highlighted pin shows Heliodyne HF 1 408 G 60 AC S E relative to the cohort median.

Efficiency comparison & rule summary

Within the 30-unit Solar with Electric Backup cohort, Heliodyne HF 1 408 G 60 AC S E logs 10.7 SUEF and ranks #16 of 30.

Solar collector & storage profile, OG-300 #30004351 for Heliodyne HF 1 408 G 60 AC S E: Direct Forced Circulation architecture; 32.2 sq ft Flat Plate collector; 60 gal storage tank; freeze limit 27 deg F.

Cross-shopping Heliodyne HF 1 408 G 60 AC S E (10.7 SUEF)? Check GREENoneTEC Double E (3.3 SUEF, delta -7.40) and AET FF-80-42 (6.7 SUEF, delta -4.00).

## Which Specs Set Heliodyne HF 1 408 G 60 AC S E Apart From Cohort Averages?

Ranked #16 of 30 inside the 30-model Solar with Electric Backup cohort, Heliodyne HF 1 408 G 60 AC S E is evaluated row by row below against category medians.

Certified model attributes compared against 30 ENERGY STAR Solar with Electric Backup peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Heliodyne](https://gcsradheat.com/brands/heliodyne/) | 6 certified listings | ENERGY STAR PD 2421037 |
| Model Number | HF 1 408 G 60 AC S E | Draw pattern: Low-Usage | HF 1 408 G 60 AC S E |
| Solar Uniform Energy Factor (SUEF) | 10.7 | -0.15 SUEF vs. 10.85 SUEF median | 10 CFR 430 Test Method |
| Solar System & Collector | Direct Forced Circulation (Flat Plate) | 32.2 sq ft aperture | OG-300 #30004351 |
| Collector Freeze Tolerance | 27 °F | SRCC freeze protection rating | ENERGY STAR Solar Dataset |
| Electrical Circuit Requirements | 240 V | Collector loop pump / controller + backup element check | NEC / Branch circuit check |
| Certification Date | 2020-11-13 | Certified 2020-11-13 | Markets: United States |

## What Should Heliodyne Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Heliodyne; run a quick serial-number check to verify age before replacing wear parts. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## How Do Five Nearby Solar with Electric Backup Models Stack Up?

Five alternative Solar with Electric Backup units with nearly identical gallon storage and SUEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | SUEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [GREENoneTEC Double E](https://gcsradheat.com/water-heaters/greenonetec/double-e/) | Solar with Electric Backup | 52 gal | — | 3.3 (-7.40) | — |
| [AET FF-80-42](https://gcsradheat.com/water-heaters/aet/ff-80-42/) | Solar with Electric Backup | 50 gal | — | 6.7 (-4.00) | — |
| [Solahart 181BTC](https://gcsradheat.com/water-heaters/solahart/181btc/) | Solar with Electric Backup | 48 gal | — | 99.0 (+88.30) | — |
| [Dimas 300-2](https://gcsradheat.com/water-heaters/dimas/300-2/) | Solar with Electric Backup | 79 gal | — | 99.0 (+88.30) | — |
| [GREENoneTEC L-Extra](https://gcsradheat.com/water-heaters/greenonetec/l-extra/) | Solar with Electric Backup | 51 gal | — | 3.3 (-7.40) | — |

## What Installation Caveats Apply Before Buying Heliodyne HF 1 408 G 60 AC S E?

Even high-UEF units like Heliodyne HF 1 408 G 60 AC S E (10.7 SUEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Heliodyne HF 1 408 G 60 AC S E logs 10.7 SUEF (Exempt — Solar SUEF); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect Heliodyne HF 1 408 G 60 AC S E's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 60 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for Heliodyne HF 1 408 G 60 AC S E** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like GREENoneTEC Double E.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Frequently Asked Technical Questions: Heliodyne HF 1 408 G 60 AC S E

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Heliodyne HF 1 408 G 60 AC S E eligible for continued manufacture past May 6, 2029?

Heliodyne HF 1 408 G 60 AC S E holds 10.7 SUEF certification in the 30-unit Solar with Electric Backup tier, remaining unaffected by the May 6, 2029 electric storage UEF mandate.

### How tall and wide is Heliodyne HF 1 408 G 60 AC S E, and what service clearance is needed?

Heliodyne HF 1 408 G 60 AC S E saves floor space via its solar with electric backup layout (wall-hung / compact envelope); inspect service-valve swing clearance below the bottom manifold.

### Will Heliodyne HF 1 408 G 60 AC S E require upgrading household electrical panels or gas piping?

Heliodyne HF 1 408 G 60 AC S E draws 240V (Collector loop pump / controller + backup element check); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is Heliodyne HF 1 408 G 60 AC S E economical to operate at 18.16 cents/kWh US electric rates?

Fuel bills for Heliodyne HF 1 408 G 60 AC S E (Solar + Electric Backup, 10.7 SUEF) hinge on household gallon demand and local gas utility tariffs compared with GREENoneTEC Double E.

### Which installation bottlenecks limit Heliodyne HF 1 408 G 60 AC S E?

Check local 10 CFR 430.32(d)(2) phase-in timing (Exempt — Solar SUEF) and physical doorway clearances before choosing Heliodyne HF 1 408 G 60 AC S E over GREENoneTEC Double E.

### How does Heliodyne HF 1 408 G 60 AC S E handle simultaneous showers and laundry?

Heliodyne HF 1 408 G 60 AC S E supplies endless hot water within its maximum BTU/flow curve—check cold-climate winter groundwater temperatures before running 3+ fixtures at once.

### How long is the warranty on Heliodyne HF 1 408 G 60 AC S E and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Heliodyne as of 2026-11-23. Confirm install proof and serial manufacture year on Heliodyne HF 1 408 G 60 AC S E before calling service.

### How do 2026 post-OBBBA rebates affect buying Heliodyne HF 1 408 G 60 AC S E?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Solar with Electric Backup is GREENoneTEC Double E (3.3 SUEF).

## Essential Pre-Install Guides for Heliodyne HF 1 408 G 60 AC S E

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare GREENoneTEC Double E (3.3 SUEF)→](https://gcsradheat.com/water-heaters/greenonetec/double-e/)
- [Compare AET FF-80-42 (6.7 SUEF)→](https://gcsradheat.com/water-heaters/aet/ff-80-42/)
- [View All Heliodyne Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/heliodyne/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Check SRCC collector freeze protection, backup tank wiring, and available post-OBBBA state DOE HEAR / utility solar incentives before replacement.
[Check 2026 State Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Model Replacement Labor](https://gcsradheat.com/costs/water-heater-replacement/)