title: "HTP PH100-55**** (0.89 UEF, 53 gal)"
url: https://gcsradheat.com/water-heaters/htp/ph100-55/
description: "Certified at 0.89 UEF across its 53-gallon nominal tank, 187 gal First Hour Rating, HTP PH100-55**** (Gas-fired Storage Residential-duty Commercial, Natural."
---

ENERGY STAR water heater model · PD 2408831

# HTP PH100-55 Water Heater Specifications (0.89 UEF)

Certified at 0.89 UEF across its 53-gallon nominal tank, 187 gal First Hour Rating, HTP PH100-55 (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane) places #8 of 71 out of 71 ENERGY STAR models (PD 2408831). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.31 / +53.4%. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Closest certified alternative is Friedrich 12PROG 50-100P FD HE EC3 (0.89 UEF).

- **Uniform Energy Factor**: 0.89 UEF

- **Cohort UEF Rank**: #8 of 71

- **First Hour Rating**: 187 gal

- **Storage Volume**: 53 gal

- **Fuel / Type**: Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial

- **DOE 2029 Rule Status**: Pass: +0.31 / +53.4%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows HTP PH100-55 relative to the cohort median.

Efficiency comparison & rule summary

Tested at 0.89 UEF, HTP PH100-55 places #8 of 71 across 71 certified Gas-fired Storage Residential-duty Commercial configurations (+0.01 UEF vs. 0.88 UEF median).

Htp ph100-55 stores 53 gal nominal; 187 gal first hour rating (+51 gal vs. 136 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d).

Closest alternatives to HTP PH100-55 include Friedrich 12PROG 50-100P FD HE EC3 (0.89 UEF, at parity) alongside Rheem ECE G50-100U CN HE EC3 (0.89 UEF, at parity).

## How Complete Are the Certified Metrics for HTP PH100-55?

Standing at #8 of 71 among 71 certified Gas-fired Storage Residential-duty Commercial heaters, HTP PH100-55 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [HTP](https://gcsradheat.com/brands/htp/) | 6 certified listings | ENERGY STAR PD 2408831 |
| Model Number | PH100-55 | Draw pattern: High-Usage | PH100-55 |
| Uniform Energy Factor (UEF) | 0.89 | +0.01 UEF vs. 0.88 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 187 gal | +51 gal vs. 136 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 99% | +4.0 pts vs. 95.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 52" H x 23" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 1 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2024-11-12 | Certified 2024-11-12 | Markets: United States, Canada |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are HTP Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched HTP in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which 5 Models Offer Similar Output to PH100-55?

Ordered by minimal capacity and UEF spread relative to HTP PH100-55, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich 12PROG 50-100P FD HE EC3](https://gcsradheat.com/water-heaters/friedrich/12prog-50-100p-fd-he-ec3/) | Gas-fired Storage Residential-duty Commercial | 50 gal | 167 gal | 0.89 (at parity) | — |
| [Rheem ECE G50-100U CN HE EC3](https://gcsradheat.com/water-heaters/rheem/ece-g50-100u-cn-he-ec3/) | Gas-fired Storage Residential-duty Commercial | 50 gal | 167 gal | 0.89 (at parity) | — |
| [Richmond 12GUH50-100F*](https://gcsradheat.com/water-heaters/richmond/12guh50-100f/) | Gas-fired Storage Residential-duty Commercial | 50 gal | 167 gal | 0.89 (at parity) | — |
| [Ruud PROU G50-100* RU HE EC3](https://gcsradheat.com/water-heaters/ruud/prou-g50-100-ru-he-ec3/) | Gas-fired Storage Residential-duty Commercial | 50 gal | 167 gal | 0.89 (at parity) | — |
| [Friedrich 12PROG 50-100U FD HE EC3](https://gcsradheat.com/water-heaters/friedrich/12prog-50-100u-fd-he-ec3/) | Gas-fired Storage Residential-duty Commercial | 50 gal | 167 gal | 0.89 (at parity) | — |

## When Should Homeowners Skip HTP PH100-55 (Gas-fired Storage Residential-duty Commercial)?

Check HTP PH100-55's mechanical constraints—including utility space, Natural Gas, Propane capacity, and Pass: +0.31 / +53.4% status—against typical residential installations.

### Key Limitations & Exclusions

- HTP PH100-55 logs 0.89 UEF (Pass: +0.31 / +53.4%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect HTP PH100-55's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 187 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for HTP PH100-55** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Friedrich 12PROG 50-100P FD HE EC3.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Practical Specs & Code Questions for HTP PH100-55

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will HTP PH100-55 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 0.89 UEF, HTP PH100-55 shows Pass: +0.31 / +53.4% relative to May 6, 2029 federal DOE limits while placing #8 of 71 among 71 Gas-fired Storage Residential-duty Commercial peers like Friedrich 12PROG 50-100P FD HE EC3.

### Will HTP PH100-55 fit through a standard utility door and 72-inch basement ceiling?

Measuring 52 in. tall by 23 in. diameter, HTP PH100-55 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support HTP PH100-55 during replacement?

Fueled by Natural Gas, Propane, HTP PH100-55 specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.

### What is the estimated 10-year operating spend for HTP PH100-55?

Because HTP PH100-55 burns Natural Gas, Propane at 0.89 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 71 peers.

### When is HTP PH100-55 a poor fit for a residential replacement?

Avoid HTP PH100-55 if household peak demand surpasses 187 gal per hour or if state DOE HEAR incentives require >=2.30 UEF heat-pump equipment.

### What First Hour Rating or flow capacity does HTP PH100-55 deliver?

With 187 gal FHR (+51 gal vs. 136 gal median), HTP PH100-55 fits larger 3–5 person homes cleanly.

### How do you verify manufacturing age and recall status on HTP PH100-55?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for HTP; verify exact manufacturing week for HTP PH100-55 using the Serial Number Lookup tool.

### Does HTP PH100-55 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for HTP PH100-55. Closest peer in Gas-fired Storage Residential-duty Commercial is Friedrich 12PROG 50-100P FD HE EC3 (0.89 UEF).

## Installation, Serial & DOE 2029 Links for PH100-55

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich 12PROG 50-100P FD HE EC3 (0.89 UEF)→](https://gcsradheat.com/water-heaters/friedrich/12prog-50-100p-fd-he-ec3/)
- [Compare Rheem ECE G50-100U CN HE EC3 (0.89 UEF)→](https://gcsradheat.com/water-heaters/rheem/ece-g50-100u-cn-he-ec3/)
- [View All HTP Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/htp/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)