title: "HTP PH100-80**** (0.93 UEF, 75 gal)"
url: https://gcsradheat.com/water-heaters/htp/ph100-80/
description: "The HTP PH100-80**** (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane) achieves a certified 0.93 UEF rating across its 75-gallon nominal."
---

ENERGY STAR water heater model · PD 2408830

# HTP PH100-80 Water Heater Specifications (0.93 UEF)

The HTP PH100-80 (Gas-fired Storage Residential-duty Commercial, Natural Gas, Propane) achieves a certified 0.93 UEF rating across its 75-gallon nominal tank, 132 gal First Hour Rating, ranking #1 of 71 among 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial models (PD 2408830). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.35 / +60.3%. Annual fuel cost depends on regional gas/fuel tariffs and needs >72 in. overhead clearance; clears 28 in. utility doorway (23" d). Closest certified alternative is Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF).

- **Uniform Energy Factor**: 0.93 UEF

- **Cohort UEF Rank**: #1 of 71 (top 1.4%)

- **First Hour Rating**: 132 gal

- **Storage Volume**: 75 gal

- **Fuel / Type**: Natural Gas, Propane / Gas-fired Storage Residential-duty Commercial

- **DOE 2029 Rule Status**: Pass: +0.35 / +60.3%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Gas-fired Storage Residential-duty Commercial UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows HTP PH100-80 relative to the cohort median.

Efficiency comparison & rule summary

HTP PH100-80 (0.93 UEF) ranks #1 of 71 Gas-fired Storage Residential-duty Commercial models — top 1.4%, more efficient than 98.6% of Gas-fired Storage Residential-duty Commercial models, +0.05 UEF above the 0.88 UEF median.

Htp ph100-80 stores 75 gal nominal; 132 gal first hour rating (-4 gal vs. 136 gal median); needs >72 in. overhead clearance; clears 28 in. utility doorway (23" d).

Peer comparison: HTP PH100-80 (0.93 UEF) compares closely with Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF, delta -0.05) and Rheem PROPG75-100P RH HE EC3 (0.88 UEF, delta -0.05).

## How Do HTP PH100-80 Specs Compare to Gas-fired Storage Residential-duty Commercial Medians?

HTP PH100-80 places #1 of 71 (top 1.4%) across 71 certified Gas-fired Storage Residential-duty Commercial configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [HTP](https://gcsradheat.com/brands/htp/) | 6 certified listings | ENERGY STAR PD 2408830 |
| Model Number | PH100-80 | Draw pattern: High-Usage | PH100-80 |
| Uniform Energy Factor (UEF) | 0.93 | +0.05 UEF vs. 0.88 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 132 gal | -4 gal vs. 136 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 99% | +4.0 pts vs. 95.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 72" H x 23" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 1 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2024-11-12 | Certified 2024-11-12 | Markets: United States, Canada |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for HTP Water Heaters?

Zero active CPSC recalls matched HTP in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Certified Water Heaters Match PH100-80 Most Closely?

These 5 competing Gas-fired Storage Residential-duty Commercial units sit nearest to HTP PH100-80 by storage capacity and 0.93 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich 12PROG 75-100P FD HE EC3](https://gcsradheat.com/water-heaters/friedrich/12prog-75-100p-fd-he-ec3/) | Gas-fired Storage Residential-duty Commercial | 75 gal | 199 gal | 0.88 (-0.05) | — |
| [Rheem PROPG75-100P RH HE EC3](https://gcsradheat.com/water-heaters/rheem/propg75-100p-rh-he-ec3/) | Gas-fired Storage Residential-duty Commercial | 75 gal | 199 gal | 0.88 (-0.05) | — |
| [Richmond 12GUH75-100FN](https://gcsradheat.com/water-heaters/richmond/12guh75-100fn/) | Gas-fired Storage Residential-duty Commercial | 75 gal | 199 gal | 0.88 (-0.05) | — |
| [Ruud PROUG75-100P RU HE EC3](https://gcsradheat.com/water-heaters/ruud/proug75-100p-ru-he-ec3/) | Gas-fired Storage Residential-duty Commercial | 75 gal | 199 gal | 0.88 (-0.05) | — |
| [Friedrich 12PROG 75-100U FD HE EC3](https://gcsradheat.com/water-heaters/friedrich/12prog-75-100u-fd-he-ec3/) | Gas-fired Storage Residential-duty Commercial | 75 gal | 199 gal | 0.88 (-0.05) | — |

## What Are the Limitations of HTP PH100-80 and Who Should Not Install It?

Before ordering HTP PH100-80 (Gas-fired Storage Residential-duty Commercial, 0.93 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- HTP PH100-80 logs 0.93 UEF (Pass: +0.35 / +60.3%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect HTP PH100-80's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 132 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for HTP PH100-80** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Friedrich 12PROG 75-100P FD HE EC3.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## What Are the Key Questions About HTP PH100-80?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does HTP PH100-80 pass the May 6, 2029 federal DOE efficiency rule?

HTP PH100-80 carries a verified 0.93 UEF rating (Pass: +0.35 / +60.3%), ranking #1 of 71 (top 1.4%) across 71 ENERGY STAR Gas-fired Storage Residential-duty Commercial models under 10 CFR 430.32.

### What doorway width and ceiling height does HTP PH100-80 need?

HTP PH100-80 stands 72 in. high with a 23 in. diameter; needs >72 in. overhead clearance; clears 28 in. utility doorway (23" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does HTP PH100-80 require?

HTP PH100-80 runs on Natural Gas, Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

### How much electricity or energy does HTP PH100-80 cost per year to run?

ENERGY STAR rates HTP PH100-80 as a Natural Gas, Propane heater (0.93 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas-fired Storage Residential-duty Commercial draw.

### Who should NOT install HTP PH100-80, and what are its limits?

HTP PH100-80 (0.93 UEF) is not suited for multi-bath marathon draws exceeding its 132 gal capacity or buyers prioritizing May 6, 2029 high-UEF HPWH rebates.

### How many bathrooms or people can HTP PH100-80 serve at peak demand?

HTP PH100-80 achieves a 132 gal First Hour Rating (-4 gal vs. 136 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for HTP PH100-80?

No active CPSC recalls matched HTP as of 2026-11-23. Always decode the serial tag on HTP PH100-80 because OEM tank/exchanger warranties span 6–12 years.

### What 2026 rebates apply to HTP PH100-80, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas-fired Storage Residential-duty Commercial is Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF).

## Which Sizing and Compliance Guides Pair with PH100-80?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich 12PROG 75-100P FD HE EC3 (0.88 UEF)→](https://gcsradheat.com/water-heaters/friedrich/12prog-75-100p-fd-he-ec3/)
- [Compare Rheem PROPG75-100P RH HE EC3 (0.88 UEF)→](https://gcsradheat.com/water-heaters/rheem/propg75-100p-rh-he-ec3/)
- [View All HTP Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/htp/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)