title: "Hubbell ME120HPT (3.38 UEF, 109 gal)"
url: https://gcsradheat.com/water-heaters/hubbell/me120hpt/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, Hubbell ME120HPT achieves a certified 3.38 UEF rating across its 109-gallon nominal tank, 105 gal."
---

ENERGY STAR water heater model · PD 2853307

# Hubbell ME120HPT Water Heater Specifications (3.38 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Hubbell ME120HPT achieves a certified 3.38 UEF rating across its 109-gallon nominal tank, 105 gal First Hour Rating and ranks #631 of 706 in its 706-model cohort (PD 2853307), recording Pass: +0.88 / +35.2% under 2029 DOE rules. Rated annual electricity draw of 1,467 kWh/yr equates to roughly $266/yr ($2,664 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Noritz NHP120 (3.38 UEF).

- **Uniform Energy Factor**: 3.38 UEF

- **Cohort UEF Rank**: #631 of 706

- **First Hour Rating**: 105 gal

- **Storage Volume**: 109 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.88 / +35.2%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Hubbell ME120HPT relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Hubbell ME120HPT logs 3.38 UEF and ranks #631 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Hubbell ME120HPT holds a +0.88 UEF (+35.2%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,467 kWh/yr for Hubbell ME120HPT runs ~$266/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for Hubbell ME120HPT: 10-year operating spend spans $2,146 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,921 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Hubbell ME120HPT (3.38 UEF)? Check Noritz NHP120 (3.38 UEF, at parity) and VAUGHN THERMAL ME120HPT (3.38 UEF, at parity).

## How Complete Are the Certified Metrics for Hubbell ME120HPT?

Standing at #631 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Hubbell ME120HPT brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Hubbell](https://gcsradheat.com/brands/hubbell/) | 4 certified listings | ENERGY STAR PD 2853307 |
| Model Number | ME120HPT | Draw pattern: High-Usage | ME120HPT |
| Uniform Energy Factor (UEF) | 3.38 | -0.32 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 105 gal | +33 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,467 kWh/yr | +395 kWh/yr vs. 1,072 kWh/yr median | Est. $266/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 355% | -74.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 84.5" H x 30" D | Needs >72 in. overhead clearance; tight at 28 in. door (30" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 54 dBA | +5 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2023-12-13 | Certified 2023-12-13 | Markets: United States, Canada |

## What Is the Projected Utility Bill for ME120HPT by State?

At 1,467 kWh/yr, Hubbell ME120HPT averages about $266/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $266/yr | $2,664 | $7,124 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $692/yr | $6,921 | $18,509 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $436/yr | $4,364 | $11,671 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $233/yr | $2,334 | $6,241 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $215/yr | $2,146 | $5,739 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,467 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are Hubbell Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Hubbell in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which 5 Models Offer Similar Output to ME120HPT?

Ordered by minimal capacity and UEF spread relative to Hubbell ME120HPT, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Noritz NHP120](https://gcsradheat.com/water-heaters/noritz/nhp120/) | Hybrid/Electric Heat Pump | 109 gal | 105 gal | 3.38 (at parity) | 1,467 |
| [VAUGHN THERMAL ME120HPT](https://gcsradheat.com/water-heaters/vaughn-thermal/me120hpt/) | Hybrid/Electric Heat Pump | 109 gal | 105 gal | 3.38 (at parity) | 1,467 |
| [SANCO2 GS5-45HPC-D HP + ECO-119GLBK](https://gcsradheat.com/water-heaters/sanco2/gs5-45hpc-d-hp-eco-119glbk/) | Hybrid/Electric Heat Pump | 119 gal | 134 gal | 3.72 (+0.34) | 1,333 |
| [Reclaim Energy MP120F-RC](https://gcsradheat.com/water-heaters/reclaim-energy/mp120f-rc/) | Hybrid/Electric Heat Pump | 119 gal | 121 gal | 3.75 (+0.37) | 1,296 |
| [VAUGHN THERMAL ME120HPT-CN](https://gcsradheat.com/water-heaters/vaughn-thermal/me120hpt-cn/) | Hybrid/Electric Heat Pump | 109 gal | 105 gal | 3.38 (at parity) | 1,467 |

## When Should Homeowners Skip Hubbell ME120HPT (Hybrid/Electric Heat Pump)?

Check Hubbell ME120HPT's mechanical constraints—including utility space, Electric capacity, and Pass: +0.88 / +35.2% status—against typical residential installations.

### Key Limitations & Exclusions

- Hubbell ME120HPT needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 54 dBA; avoid mounting Hubbell ME120HPT directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Hubbell ME120HPT** Strong Fit — 3.38 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Noritz NHP120 footprint.

## Practical Specs & Code Questions for Hubbell ME120HPT

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will Hubbell ME120HPT stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.38 UEF, Hubbell ME120HPT shows Pass: +0.88 / +35.2% relative to May 6, 2029 federal DOE limits while placing #631 of 706 among 706 Hybrid/Electric Heat Pump peers like Noritz NHP120.

### Will Hubbell ME120HPT fit through a standard utility door and 72-inch basement ceiling?

Measuring 84.5 in. tall by 30 in. diameter, Hubbell ME120HPT notes: needs >72 in. overhead clearance; tight at 28 in. door (30" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support Hubbell ME120HPT during replacement?

Electrical specs for Hubbell ME120HPT call for 240V at 23A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for Hubbell ME120HPT?

At 18.16 cents/kWh national residential pricing, Hubbell ME120HPT's 1,467 kWh/yr draw equals roughly $266 annually or $2,660 across a 10-year horizon (ranging from $215/yr in Washington hydro tiers up to $692/yr in Hawaii).

### When is Hubbell ME120HPT a poor fit for a residential replacement?

Avoid placing Hubbell ME120HPT directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 54 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does Hubbell ME120HPT deliver?

With 105 gal FHR (+33 gal vs. 72 gal median), Hubbell ME120HPT fits larger 3–5 person homes cleanly.

### How do you verify manufacturing age and recall status on Hubbell ME120HPT?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Hubbell; verify exact manufacturing week for Hubbell ME120HPT using the Serial Number Lookup tool.

### Does Hubbell ME120HPT qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Hubbell ME120HPT. Closest peer in Hybrid/Electric Heat Pump is Noritz NHP120 (3.38 UEF).

## Installation, Serial & DOE 2029 Links for ME120HPT

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Noritz NHP120 (3.38 UEF)→](https://gcsradheat.com/water-heaters/noritz/nhp120/)
- [Compare VAUGHN THERMAL ME120HPT (3.38 UEF)→](https://gcsradheat.com/water-heaters/vaughn-thermal/me120hpt/)
- [View All Hubbell Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/hubbell/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)