title: "Hubbell ME50HPT (3.46 UEF, 47 gal)"
url: https://gcsradheat.com/water-heaters/hubbell/me50hpt/
description: "The Hubbell ME50HPT (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.46 UEF rating across its 47-gallon nominal tank, 58 gal First Hour Rating."
---

ENERGY STAR water heater model · PD 2853390

# Hubbell ME50HPT Water Heater Specifications (3.46 UEF)

The Hubbell ME50HPT (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.46 UEF rating across its 47-gallon nominal tank, 58 gal First Hour Rating, ranking #549 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2853390). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.16 / +50.4%. Rated annual electricity draw of 938 kWh/yr equates to roughly $170/yr ($1,703 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Noritz NHP50 (3.46 UEF).

- **Uniform Energy Factor**: 3.46 UEF

- **Cohort UEF Rank**: #549 of 706

- **First Hour Rating**: 58 gal

- **Storage Volume**: 47 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.16 / +50.4%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Hubbell ME50HPT relative to the cohort median.

Efficiency comparison & rule summary

Hubbell ME50HPT (3.46 UEF) ranks #549 of 706 Hybrid/Electric Heat Pump models — 14-way tie; more efficient than 20.4% of Hybrid/Electric Heat Pump models, -0.24 UEF below the 3.70 UEF median.

Federal 2029 margin for Hubbell ME50HPT: +1.16 UEF (+50.4%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 938 kWh/yr for Hubbell ME50HPT runs ~$170/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Hubbell ME50HPT: 10-year operating spend spans $1,372 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,425 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Hubbell ME50HPT (3.46 UEF) compares closely with Noritz NHP50 (3.46 UEF, at parity) and VAUGHN THERMAL ME50HPT (3.46 UEF, at parity).

## How Do Hubbell ME50HPT Specs Compare to Hybrid/Electric Heat Pump Medians?

Hubbell ME50HPT places #549 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Hubbell](https://gcsradheat.com/brands/hubbell/) | 4 certified listings | ENERGY STAR PD 2853390 |
| Model Number | ME50HPT | Draw pattern: Medium-Usage | ME50HPT |
| Uniform Energy Factor (UEF) | 3.46 | -0.24 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 58 gal | -14 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 938 kWh/yr | -134 kWh/yr vs. 1,072 kWh/yr median | Est. $170/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 373% | -56.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 58.3" H x 28" D | Fits standard 72 in. basement/garage clearance; tight at 28 in. door (28" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 54 dBA | +5 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2023-12-13 | Certified 2023-12-13 | Markets: United States, Canada |

## What Does ME50HPT Cost to Operate Across State Electricity Rates?

At 938 kWh/yr, Hubbell ME50HPT runs roughly $170/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $170/yr | $1,703 | $4,703 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $443/yr | $4,425 | $12,220 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $279/yr | $2,791 | $7,705 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $149/yr | $1,492 | $4,121 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $137/yr | $1,372 | $3,789 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (938 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for Hubbell Water Heaters?

Zero active CPSC recalls matched Hubbell in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Certified Water Heaters Match ME50HPT Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Hubbell ME50HPT by storage capacity and 3.46 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Noritz NHP50](https://gcsradheat.com/water-heaters/noritz/nhp50/) | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (at parity) | 938 |
| [VAUGHN THERMAL ME50HPT](https://gcsradheat.com/water-heaters/vaughn-thermal/me50hpt/) | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (at parity) | 938 |
| [Carnot Labs, Inc. N51](https://gcsradheat.com/water-heaters/carnot-labs-inc/n51/) | Hybrid/Electric Heat Pump | 47 gal | 75 gal | 3.53 (+0.07) | 1,404 |
| [1HVAC ACIQ-50G-HP-WH](https://gcsradheat.com/water-heaters/1hvac/aciq-50g-hp-wh/) | Hybrid/Electric Heat Pump | 47 gal | 69 gal | 3.75 (+0.29) | 855 |
| [VAUGHN THERMAL ME50HPT-CN](https://gcsradheat.com/water-heaters/vaughn-thermal/me50hpt-cn/) | Hybrid/Electric Heat Pump | 47 gal | 58 gal | 3.46 (at parity) | 938 |

## What Installation Caveats Apply Before Buying Hubbell ME50HPT?

Even high-UEF units like Hubbell ME50HPT (3.46 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Hubbell ME50HPT needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 54 dBA; avoid mounting Hubbell ME50HPT directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Hubbell ME50HPT** Strong Fit — 3.46 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Noritz NHP50 footprint.

## What Are the Key Questions About Hubbell ME50HPT?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Hubbell ME50HPT eligible for continued manufacture past May 6, 2029?

At 3.46 UEF, Hubbell ME50HPT achieves Pass: +1.16 / +50.4% for the 2029 DOE standard and stands #549 of 706 against Noritz NHP50 and VAUGHN THERMAL ME50HPT.

### How tall and wide is Hubbell ME50HPT, and what service clearance is needed?

Physical dimensions for Hubbell ME50HPT are 58.3 in. height and 28 in. diameter (fits standard 72 in. basement/garage clearance; tight at 28 in. door (28" d)); verify stair turns and drain pan width before delivery.

### Will Hubbell ME50HPT require upgrading household electrical panels or gas piping?

Hubbell ME50HPT draws 240V at 23A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is Hubbell ME50HPT economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $170/yr ($1,700 over 10 years) to power Hubbell ME50HPT at 938 kWh/yr under the 18.16 cents/kWh US average (ranging from $137/yr in Washington hydro tiers up to $443/yr in Hawaii).

### Which installation bottlenecks limit Hubbell ME50HPT?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Hubbell ME50HPT drops into resistance mode more often.

### How does Hubbell ME50HPT handle simultaneous showers and laundry?

Delivering 58 gal in the first hour (-14 gal vs. 72 gal median), Hubbell ME50HPT combines 47 gal tank storage with rapid burner/element recovery.

### How long is the warranty on Hubbell ME50HPT and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Hubbell as of 2026-11-23. Confirm install proof and serial manufacture year on Hubbell ME50HPT before calling service.

### How do 2026 post-OBBBA rebates affect buying Hubbell ME50HPT?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Noritz NHP50 (3.46 UEF).

## Which Sizing and Compliance Guides Pair with ME50HPT?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Noritz NHP50 (3.46 UEF)→](https://gcsradheat.com/water-heaters/noritz/nhp50/)
- [Compare VAUGHN THERMAL ME50HPT (3.46 UEF)→](https://gcsradheat.com/water-heaters/vaughn-thermal/me50hpt/)
- [View All Hubbell Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/hubbell/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)