title: "Hubbell ME80HPT (3.48 UEF, 74 gal)"
url: https://gcsradheat.com/water-heaters/hubbell/me80hpt/
description: "In the 706-unit Hybrid/Electric Heat Pump class, Hubbell ME80HPT (Electric) achieves a certified 3.48 UEF rating across its 74-gallon nominal tank, 86 gal."
---

ENERGY STAR water heater model · PD 2853344

# Hubbell ME80HPT Water Heater Specifications (3.48 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Hubbell ME80HPT (Electric) achieves a certified 3.48 UEF rating across its 74-gallon nominal tank, 86 gal First Hour Rating (rank #545 of 706, PD 2853344) and verifies as Pass: +0.98 / +39.2% for 2029 DOE floors. Rated annual electricity draw of 1,424 kWh/yr equates to roughly $259/yr ($2,586 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Noritz NHP80 (3.48 UEF).

- **Uniform Energy Factor**: 3.48 UEF

- **Cohort UEF Rank**: #545 of 706

- **First Hour Rating**: 86 gal

- **Storage Volume**: 74 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.98 / +39.2%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Hubbell ME80HPT relative to the cohort median.

Efficiency comparison & rule summary

Hubbell ME80HPT records 3.48 UEF efficiency, putting it #545 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Hubbell ME80HPT exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.98 UEF (+39.2%). At EIA August 2026 national rates (18.16 cents/kWh), 1,424 kWh/yr for Hubbell ME80HPT runs ~$259/yr vs. ~$978/yr for a 0.92 UEF electric tank.

State electric sensitivity for Hubbell ME80HPT: 10-year operating spend spans $2,083 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,718 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Hubbell ME80HPT (3.48 UEF) are Noritz NHP80 (3.48 UEF, at parity) and VAUGHN THERMAL ME80HPT (3.48 UEF, at parity).

## What Physical and Thermal Ratings Define Hubbell ME80HPT?

Positioning at #545 of 706 out of 706 Hybrid/Electric Heat Pump peers, Hubbell ME80HPT pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Hubbell](https://gcsradheat.com/brands/hubbell/) | 4 certified listings | ENERGY STAR PD 2853344 |
| Model Number | ME80HPT | Draw pattern: High-Usage | ME80HPT |
| Uniform Energy Factor (UEF) | 3.48 | -0.22 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 86 gal | +14 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,424 kWh/yr | +352 kWh/yr vs. 1,072 kWh/yr median | Est. $259/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 365% | -64.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74" H x 28" D | Needs >72 in. overhead clearance; tight at 28 in. door (28" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 54 dBA | +5 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2023-12-13 | Certified 2023-12-13 | Markets: United States, Canada |

## Why Do State Utility Rates Shift ME80HPT Running Costs?

Consuming 1,424 kWh annually puts Hubbell ME80HPT near $259/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $259/yr | $2,586 | $7,195 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $672/yr | $6,718 | $18,693 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $424/yr | $4,236 | $11,787 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $227/yr | $2,266 | $6,304 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $208/yr | $2,083 | $5,796 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,424 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any Hubbell Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Hubbell; confirm tank age separately using the rating-plate serial pattern. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## What Are 5 Direct Alternatives to Hubbell ME80HPT?

Homeowners cross-shopping Hubbell ME80HPT frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Noritz NHP80](https://gcsradheat.com/water-heaters/noritz/nhp80/) | Hybrid/Electric Heat Pump | 74 gal | 86 gal | 3.48 (at parity) | 1,424 |
| [VAUGHN THERMAL ME80HPT](https://gcsradheat.com/water-heaters/vaughn-thermal/me80hpt/) | Hybrid/Electric Heat Pump | 74 gal | 86 gal | 3.48 (at parity) | 1,424 |
| [1HVAC ACIQ-80G-HP-WH](https://gcsradheat.com/water-heaters/1hvac/aciq-80g-hp-wh/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (+0.52) | 1,240 |
| [ACIQ ACIQ-80G-HP-WH](https://gcsradheat.com/water-heaters/aciq/aciq-80g-hp-wh/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (+0.52) | 1,240 |
| [VAUGHN THERMAL ME80HPT-CN](https://gcsradheat.com/water-heaters/vaughn-thermal/me80hpt-cn/) | Hybrid/Electric Heat Pump | 74 gal | 86 gal | 3.48 (at parity) | 1,424 |

## Who Is Hubbell ME80HPT Best For — and When Should You Pick Noritz NHP80?

Evaluate whether Hubbell ME80HPT's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- Hubbell ME80HPT needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 54 dBA; avoid mounting Hubbell ME80HPT directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Hubbell ME80HPT** Strong Fit — 3.48 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Noritz NHP80 footprint.

## Sizing, Efficiency & Recall Answers for Hubbell ME80HPT

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Hubbell ME80HPT (3.48 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Hubbell ME80HPT records 3.48 UEF (Pass: +0.98 / +39.2%), placing #545 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does Hubbell ME80HPT fit inside a tight hallway closet or low-headroom utility room?

Hubbell ME80HPT requires room for its 74 in. vertical shell and 28 in. diameter (needs >72 in. overhead clearance; tight at 28 in. door (28" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern Hubbell ME80HPT?

For Hubbell ME80HPT, plan a 240V circuit at 23A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for Hubbell ME80HPT?

Using 1,424 kWh/yr, Hubbell ME80HPT generates an estimated $259/yr electric bill at 18.16 cents/kWh (ranging from $208/yr in Washington hydro tiers up to $672/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of Hubbell ME80HPT (3.48 UEF)?

Hubbell ME80HPT requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Noritz NHP80.

### What hot-water delivery rating governs Hubbell ME80HPT?

Rated for 86 gal FHR (+14 gal vs. 72 gal median), Hubbell ME80HPT prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen Hubbell ME80HPT for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Hubbell; use our browser-only serial decoder to inspect Hubbell ME80HPT's age and warranty window.

### What alternative models sit closest to Hubbell ME80HPT in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Noritz NHP80 (3.48 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Related Rebate, Gas-Line & Serial Tools for ME80HPT

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Noritz NHP80 (3.48 UEF)→](https://gcsradheat.com/water-heaters/noritz/nhp80/)
- [Compare VAUGHN THERMAL ME80HPT (3.48 UEF)→](https://gcsradheat.com/water-heaters/vaughn-thermal/me80hpt/)
- [View All Hubbell Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/hubbell/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)