title: "John Wood JTHR-199M 1** (0.95 UEF, Gas Tankless)"
url: https://gcsradheat.com/water-heaters/john-wood/jthr-199m-1/
description: "Engineered as a Natural Gas, Propane Gas Tankless unit, John Wood JTHR-199M 1** achieves a certified 0.95 UEF rating and ranks #159 of 464 in its 464-model."
---

ENERGY STAR water heater model · PD 2862497

# John Wood JTHR-199M 1** Water Heater Specifications (0.95 UEF)

Engineered as a Natural Gas, Propane Gas Tankless unit, John Wood JTHR-199M 1** achieves a certified 0.95 UEF rating and ranks #159 of 464 in its 464-model cohort (PD 2862497), recording Pass: +0.04 / +4.4% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

- **Uniform Energy Factor**: 0.95 UEF

- **Cohort UEF Rank**: #159 of 464

- **First Hour Rating**: On-Demand

- **Storage Volume**: Tankless

- **Fuel / Type**: Natural Gas, Propane / Gas Tankless

- **DOE 2029 Rule Status**: Pass: +0.04 / +4.4%

Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils

Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows John Wood JTHR-199M 1** relative to the cohort median.

Efficiency comparison & rule summary

Within the 464-unit Gas Tankless cohort, John Wood JTHR-199M 1** logs 0.95 UEF and ranks #159 of 464.

John Wood JTHR-199M 1** delivers +0.04 UEF (+4.4%) margin above the 0.91 UEF Natural Gas, Propane tankless mandate; thermal recovery tests at 98% (At 98.0% median).

Cross-shopping John Wood JTHR-199M 1** (0.95 UEF)? Check A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) and American GT-240-NEH 1** (0.95 UEF, at parity).

## Which Specs Set John Wood JTHR-199M 1** Apart From Cohort Averages?

Ranked #159 of 464 inside the 464-model Gas Tankless cohort, John Wood JTHR-199M 1** is evaluated row by row below against category medians.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [John Wood](https://gcsradheat.com/brands/john-wood/) | 17 certified listings | ENERGY STAR PD 2862497 |
| Model Number | JTHR-199M 1** | Draw pattern: High-Usage | JTHR-199M 1** |
| Uniform Energy Factor (UEF) | 0.95 | At 0.95 UEF median | 10 CFR 430 Test Method |
| Thermal Recovery Efficiency | 98% | At 98.0% median | ENERGY STAR Dataset |
| Electrical Circuit Requirements | 5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2023-12-18 | Certified 2023-12-18 | Markets: Canada |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should John Wood Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for John Wood; run a quick serial-number check to verify age before replacing wear parts. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## How Do Five Nearby Gas Tankless Models Stack Up?

Five alternative Gas Tankless units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith ACT-199O-N 1**](https://gcsradheat.com/water-heaters/a-o-smith/act-199o-n-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [American GT-240-NEH 1**](https://gcsradheat.com/water-heaters/american/gt-240-neh-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [Bosch T9800 SE 160](https://gcsradheat.com/water-heaters/bosch/t9800-se-160/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [Bradford White RTG-K-160N1](https://gcsradheat.com/water-heaters/bradford-white/rtg-k-160n1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [A. O. Smith ACT-199O-P 1*1](https://gcsradheat.com/water-heaters/a-o-smith/act-199o-p-1-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |

## What Are the Limitations of John Wood JTHR-199M 1** and Who Should Not Install It?

Before ordering John Wood JTHR-199M 1** (Gas Tankless, 0.95 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- Converting a 40K tank to John Wood JTHR-199M 1** often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
- Hard tap water >=7.0 GPG requires annual vinegar descaling to protect John Wood JTHR-199M 1**'s heat exchanger.
- Condensing John Wood JTHR-199M 1** requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

### Which Option Fits Your Situation?

**Existing 3/4 in.+ Gas Line + Marathon Hot Draws** Strong Fit — John Wood JTHR-199M 1** delivers continuous 0.95 UEF performance.

**Softened/Low-Scale Water (<7.0 GPG)** Strong Fit — Minimal calcium scale between 12-month flushes.

**Long 1/2 in. Gas Run (>10 ft)** Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

## Frequently Asked Technical Questions: John Wood JTHR-199M 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does John Wood JTHR-199M 1** pass the May 6, 2029 federal DOE efficiency rule?

John Wood JTHR-199M 1** carries a verified 0.95 UEF rating (Pass: +0.04 / +4.4%), ranking #159 of 464 across 464 ENERGY STAR Gas Tankless models under 10 CFR 430.32.

### What doorway width and ceiling height does John Wood JTHR-199M 1** need?

John Wood JTHR-199M 1** mounts as a gas tankless without a bulky floor tank (wall-hung / compact envelope). Verify vent termination distances and combustion air clearances per IPC or UPC.

### What gas pipe size or electrical breaker does John Wood JTHR-199M 1** require?

John Wood JTHR-199M 1** runs on Natural Gas, Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

### How much electricity or energy does John Wood JTHR-199M 1** cost per year to run?

ENERGY STAR rates John Wood JTHR-199M 1** as a Natural Gas, Propane heater (0.95 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas Tankless draw.

### Who should NOT install John Wood JTHR-199M 1**, and what are its limits?

John Wood JTHR-199M 1** (0.95 UEF) is rarely a drop-in swap over a 40K tank if existing 1/2 in. gas pipe cannot supply 199,000 BTU/h or hardness exceeds 7.0 GPG without descaling.

### How many bathrooms or people can John Wood JTHR-199M 1** serve at peak demand?

John Wood JTHR-199M 1** provides continuous Gas Tankless delivery rather than a fixed storage FHR; size GPM flow against winter incoming groundwater temperature and 2.0 GPM showers.

### Are there CPSC safety recalls or serial checks for John Wood JTHR-199M 1**?

No active CPSC recalls matched John Wood as of 2026-11-23. Always decode the serial tag on John Wood JTHR-199M 1** because OEM tank/exchanger warranties span 6–12 years.

### What 2026 rebates apply to John Wood JTHR-199M 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

## Essential Pre-Install Guides for John Wood JTHR-199M 1**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith ACT-199O-N 1** (0.95 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/act-199o-n-1/)
- [Compare American GT-240-NEH 1** (0.95 UEF)→](https://gcsradheat.com/water-heaters/american/gt-240-neh-1/)
- [View All John Wood Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/john-wood/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)