title: "Lennox WHHP065T45MD240S**** (4.05 UEF, 61 gal)"
url: https://gcsradheat.com/water-heaters/lennox/whhp065t45md240s/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, Lennox WHHP065T45MD240S**** achieves a certified 4.05 UEF rating across its 61-gallon nominal tank, 77."
---

ENERGY STAR water heater model · PD 4570022

# Lennox WHHP065T45MD240S Water Heater Specifications (4.05 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Lennox WHHP065T45MD240S achieves a certified 4.05 UEF rating across its 61-gallon nominal tank, 77 gal First Hour Rating and ranks #61 of 706 in its 706-model cohort (PD 4570022), recording Pass: +1.55 / +62.0% under 2029 DOE rules. Rated annual electricity draw of 1,225 kWh/yr equates to roughly $222/yr ($2,225 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-65-T (4.05 UEF).

- **Uniform Energy Factor**: 4.05 UEF

- **Cohort UEF Rank**: #61 of 706 (top 14.2%)

- **First Hour Rating**: 77 gal

- **Storage Volume**: 61 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.55 / +62.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lennox WHHP065T45MD240S relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Lennox WHHP065T45MD240S logs 4.05 UEF and ranks #61 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Lennox WHHP065T45MD240S holds a +1.55 UEF (+62.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,225 kWh/yr for Lennox WHHP065T45MD240S runs ~$222/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for Lennox WHHP065T45MD240S: 10-year operating spend spans $1,792 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,780 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Lennox WHHP065T45MD240S (4.05 UEF)? Check Ariston ARIHPWH-65-T (4.05 UEF, at parity) and Navien NWP500S065AUMB (4.03 UEF, delta -0.02).

## How Do Lennox WHHP065T45MD240S Specs Compare to Hybrid/Electric Heat Pump Medians?

Lennox WHHP065T45MD240S places #61 of 706 (top 14.2%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Lennox](https://gcsradheat.com/brands/lennox/) | 4 certified listings | ENERGY STAR PD 4570022 |
| Model Number | WHHP065T45MD240S | Draw pattern: High-Usage | WHHP065T45MD240S |
| Uniform Energy Factor (UEF) | 4.05 | +0.35 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 77 gal | +5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,225 kWh/yr | +153 kWh/yr vs. 1,072 kWh/yr median | Est. $222/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 446% | +17.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 50.5" H x 20.2" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-02-25 | Certified 2026-02-25 | Markets: United States, Canada |

## What Does WHHP065T45MD240S Cost to Operate Across State Electricity Rates?

At 1,225 kWh/yr, Lennox WHHP065T45MD240S runs roughly $222/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $222/yr | $2,225 | $7,569 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $578/yr | $5,780 | $19,665 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $364/yr | $3,644 | $12,400 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $195/yr | $1,949 | $6,631 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $179/yr | $1,792 | $6,098 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,225 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for Lennox Water Heaters?

Zero active CPSC recalls matched Lennox in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Certified Water Heaters Match WHHP065T45MD240S Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Lennox WHHP065T45MD240S by storage capacity and 4.05 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Ariston ARIHPWH-65-T](https://gcsradheat.com/water-heaters/ariston/arihpwh-65-t/) | Hybrid/Electric Heat Pump | 61 gal | 77 gal | 4.05 (at parity) | 1,225 |
| [Navien NWP500S065AUMB](https://gcsradheat.com/water-heaters/navien/nwp500s065aumb/) | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.03 (-0.02) | 1,245 |
| [Midea CAN3-RSJ-15/250RDVN3-L4](https://gcsradheat.com/water-heaters/midea/can3-rsj-15-250rdvn3-l4/) | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.0 (-0.05) | 1,234 |
| [Rinnai REHP65CW*](https://gcsradheat.com/water-heaters/rinnai/rehp65cw/) | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.0 (-0.05) | 1,234 |
| [Midea MAHW-65VN3B](https://gcsradheat.com/water-heaters/midea/mahw-65vn3b/) | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.0 (-0.05) | 1,234 |

## Which Home Setups Are NOT a Fit for Lennox WHHP065T45MD240S?

Comparing Lennox WHHP065T45MD240S against Ariston ARIHPWH-65-T requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- Lennox WHHP065T45MD240S needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Lennox WHHP065T45MD240S directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Lennox WHHP065T45MD240S** Strong Fit — 4.05 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Ariston ARIHPWH-65-T footprint.

## What Are the Key Questions About Lennox WHHP065T45MD240S?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Lennox WHHP065T45MD240S score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Lennox WHHP065T45MD240S logs 4.05 UEF (Pass: +1.55 / +62.0%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing Lennox WHHP065T45MD240S?

With a 50.5 in. height and 20.2 in. diameter, Lennox WHHP065T45MD240S fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits Lennox WHHP065T45MD240S?

Powered via 240V at 21A max, Lennox WHHP065T45MD240S requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for Lennox WHHP065T45MD240S?

Annual electric spend for Lennox WHHP065T45MD240S (1,225 kWh/yr) averages $222/yr nationwide (ranging from $179/yr in Washington hydro tiers up to $578/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing Lennox WHHP065T45MD240S?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Lennox WHHP065T45MD240S.

### Is Lennox WHHP065T45MD240S sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Lennox WHHP065T45MD240S at 77 gal First Hour Rating (+5 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does Lennox have active CPSC SaferProducts notices affecting WHHP065T45MD240S?

Zero CPSC recall alerts matched Lennox (2026-11-23 check). Keep your Lennox WHHP065T45MD240S serial code handy to track standard 6-to-12-year OEM warranty coverage.

### Which competing water heater matches Lennox WHHP065T45MD240S (4.05 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Lennox WHHP065T45MD240S. Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-65-T (4.05 UEF).

## Which Sizing and Compliance Guides Pair with WHHP065T45MD240S?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Ariston ARIHPWH-65-T (4.05 UEF)→](https://gcsradheat.com/water-heaters/ariston/arihpwh-65-t/)
- [Compare Navien NWP500S065AUMB (4.03 UEF)→](https://gcsradheat.com/water-heaters/navien/nwp500s065aumb/)
- [View All Lennox Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/lennox/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)