# Lennox WHHP080T45MD240S Water Heater Specifications (4.1 UEF)

Certified at 4.1 UEF across its 74-gallon nominal tank, 88 gal First Hour Rating, Lennox WHHP080T45MD240S (Hybrid/Electric Heat Pump, Electric) places #20 of 706 out of 706 ENERGY STAR models (PD 4570021). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.60 / +64.0%. Rated annual electricity draw of 1,210 kWh/yr equates to roughly $220/yr ($2,197 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-80-T (4.1 UEF).

- **Uniform Energy Factor**: 4.1 UEF

- **Cohort UEF Rank**: #20 of 706 (top 3.5%)

- **First Hour Rating**: 88 gal

- **Storage Volume**: 74 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.60 / +64.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lennox WHHP080T45MD240S relative to the cohort median.

Efficiency comparison & rule summary

Tested at 4.1 UEF, Lennox WHHP080T45MD240S places #20 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.40 UEF vs. 3.70 UEF median).

Lennox WHHP080T45MD240S clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.60 UEF (+64.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,210 kWh/yr for Lennox WHHP080T45MD240S runs ~$220/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for Lennox WHHP080T45MD240S: 10-year operating spend spans $1,770 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,709 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Lennox WHHP080T45MD240S include Ariston ARIHPWH-80-T (4.1 UEF, at parity) alongside Eco-Logical OMNI-80HP2-1A (4.11 UEF, delta +0.01).

## Where Does Lennox WHHP080T45MD240S Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Lennox WHHP080T45MD240S holds #20 of 706 (top 3.5%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Lennox](https://gcsradheat.com/brands/lennox/) | 4 certified listings | ENERGY STAR PD 4570021 |
| Model Number | WHHP080T45MD240S | Draw pattern: High-Usage | WHHP080T45MD240S |
| Uniform Energy Factor (UEF) | 4.1 | +0.40 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 88 gal | +16 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,210 kWh/yr | +138 kWh/yr vs. 1,072 kWh/yr median | Est. $220/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 474% | +45.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 59.8" H x 20.2" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-02-25 | Certified 2026-02-25 | Markets: United States, Canada |

## How Much Electricity Does WHHP080T45MD240S Use in Different States?

Estimated at $220/yr nationally (1,210 kWh/yr), 10-year utility spending for Lennox WHHP080T45MD240S shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $220/yr | $2,197 | $7,595 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $571/yr | $5,709 | $19,731 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $360/yr | $3,600 | $12,441 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $193/yr | $1,925 | $6,654 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $177/yr | $1,770 | $6,118 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,210 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on Lennox Units?

No open CPSC recall alerts appeared for Lennox as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to WHHP080T45MD240S?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Lennox WHHP080T45MD240S's gallon capacity and 4.1 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Ariston ARIHPWH-80-T](https://gcsradheat.com/water-heaters/ariston/arihpwh-80-t/) | Hybrid/Electric Heat Pump | 74 gal | 88 gal | 4.1 (at parity) | 1,210 |
| [Eco-Logical OMNI-80HP2-1A](https://gcsradheat.com/water-heaters/eco-logical/omni-80hp2-1a/) | Hybrid/Electric Heat Pump | 74 gal | 82 gal | 4.11 (+0.01) | 1,206 |
| [Navien NWP500S080AUMB](https://gcsradheat.com/water-heaters/navien/nwp500s080aumb/) | Hybrid/Electric Heat Pump | 74 gal | 85 gal | 4.05 (-0.05) | 1,265 |
| [1HVAC ACIQ-80G-HP-WH](https://gcsradheat.com/water-heaters/1hvac/aciq-80g-hp-wh/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (-0.10) | 1,240 |
| [ACIQ ACIQ-80G-HP-WH](https://gcsradheat.com/water-heaters/aciq/aciq-80g-hp-wh/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (-0.10) | 1,240 |

## What Installation Caveats Apply Before Buying Lennox WHHP080T45MD240S?

Even high-UEF units like Lennox WHHP080T45MD240S (4.1 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Lennox WHHP080T45MD240S needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Lennox WHHP080T45MD240S directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Lennox WHHP080T45MD240S** Strong Fit — 4.1 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Ariston ARIHPWH-80-T footprint.

## Common Homeowner Questions for Lennox WHHP080T45MD240S

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Lennox WHHP080T45MD240S eligible for continued manufacture past May 6, 2029?

At 4.1 UEF, Lennox WHHP080T45MD240S achieves Pass: +1.60 / +64.0% for the 2029 DOE standard and stands #20 of 706 (top 3.5%) against Ariston ARIHPWH-80-T and Eco-Logical OMNI-80HP2-1A.

### How tall and wide is Lennox WHHP080T45MD240S, and what service clearance is needed?

Physical dimensions for Lennox WHHP080T45MD240S are 59.8 in. height and 20.2 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" d)); verify stair turns and drain pan width before delivery.

### Will Lennox WHHP080T45MD240S require upgrading household electrical panels or gas piping?

Lennox WHHP080T45MD240S draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is Lennox WHHP080T45MD240S economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $220/yr ($2,200 over 10 years) to power Lennox WHHP080T45MD240S at 1,210 kWh/yr under the 18.16 cents/kWh US average (ranging from $177/yr in Washington hydro tiers up to $571/yr in Hawaii).

### Which installation bottlenecks limit Lennox WHHP080T45MD240S?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Lennox WHHP080T45MD240S drops into resistance mode more often.

### How does Lennox WHHP080T45MD240S handle simultaneous showers and laundry?

Delivering 88 gal in the first hour (+16 gal vs. 72 gal median), Lennox WHHP080T45MD240S combines 74 gal tank storage with rapid burner/element recovery.

### How long is the warranty on Lennox WHHP080T45MD240S and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Lennox as of 2026-11-23. Confirm install proof and serial manufacture year on Lennox WHHP080T45MD240S before calling service.

### How do 2026 post-OBBBA rebates affect buying Lennox WHHP080T45MD240S?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-80-T (4.1 UEF).

## Next Engineering Checks for Lennox Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Ariston ARIHPWH-80-T (4.1 UEF)→](https://gcsradheat.com/water-heaters/ariston/arihpwh-80-t/)
- [Compare Eco-Logical OMNI-80HP2-1A (4.11 UEF)→](https://gcsradheat.com/water-heaters/eco-logical/omni-80hp2-1a/)
- [View All Lennox Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/lennox/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)