title: "LG APHWC502L (4.2 UEF, 53 gal) — TapAndPipe"
url: https://gcsradheat.com/water-heaters/lg/aphwc502l/
description: "With PD 4520748 certification, LG APHWC502L (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.2 UEF rating across its 53-gallon nominal tank, 81 gal."
---

ENERGY STAR water heater model · PD 4520748

# LG APHWC502L Water Heater Specifications (4.2 UEF)

With PD 4520748 certification, LG APHWC502L (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.2 UEF rating across its 53-gallon nominal tank, 81 gal First Hour Rating, standing #10 of 706 across 706 peers with Pass: +1.90 / +82.6% for May 6, 2029. Rated annual electricity draw of 1,181 kWh/yr equates to roughly $214/yr ($2,145 over 10 years) at 18.16 cents/kWh. Closest certified alternative is GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF).

- **Uniform Energy Factor**: 4.2 UEF

- **Cohort UEF Rank**: #10 of 706 (top 2.3%)

- **First Hour Rating**: 81 gal

- **Storage Volume**: 53 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.90 / +82.6%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows LG APHWC502L relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places LG APHWC502L at 4.2 UEF (#10 of 706; +0.50 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: LG APHWC502L stands +1.90 UEF (+82.6%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,181 kWh/yr for LG APHWC502L runs ~$214/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for LG APHWC502L: 10-year operating spend spans $1,728 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,572 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF, delta -0.18) and VAUGHN THERMAL MP55FHPT (3.3 UEF, delta -0.90) bracket LG APHWC502L.

## Where Does LG APHWC502L Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, LG APHWC502L holds #10 of 706 (top 2.3%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [LG](https://gcsradheat.com/brands/lg/) | 12 certified listings | ENERGY STAR PD 4520748 |
| Model Number | APHWC502L | Draw pattern: High-Usage | APHWC502L |
| Uniform Energy Factor (UEF) | 4.2 | +0.50 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 81 gal | +9 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,181 kWh/yr | +109 kWh/yr vs. 1,072 kWh/yr median | Est. $214/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 440% | +11.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 47.6" H x 19.7" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (19.7" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-02-25 | Certified 2026-02-25 | Markets: United States |

## How Much Electricity Does APHWC502L Use in Different States?

Estimated at $214/yr nationally (1,181 kWh/yr), 10-year utility spending for LG APHWC502L shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $214/yr | $2,145 | $7,647 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $557/yr | $5,572 | $19,867 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $351/yr | $3,513 | $12,528 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $188/yr | $1,879 | $6,700 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $173/yr | $1,728 | $6,161 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,181 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on LG Units?

No open CPSC recall alerts appeared for LG as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to APHWC502L?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to LG APHWC502L's gallon capacity and 4.2 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [GREE GRS-3.0Pd/TD50GANhA-D](https://gcsradheat.com/water-heaters/gree/grs-3-0pd-td50ganha-d/) | Hybrid/Electric Heat Pump | 55 gal | 80 gal | 4.02 (-0.18) | 1,234 |
| [VAUGHN THERMAL MP55FHPT](https://gcsradheat.com/water-heaters/vaughn-thermal/mp55fhpt/) | Hybrid/Electric Heat Pump | 55 gal | 62 gal | 3.3 (-0.90) | 982 |
| [GE Profile PK50S10FNY01](https://gcsradheat.com/water-heaters/ge-profile/pk50s10fny01/) | Hybrid/Electric Heat Pump | 50 gal | 60 gal | 4.2 (at parity) | 773 |
| [Hubbell ME65HPT](https://gcsradheat.com/water-heaters/hubbell/me65hpt/) | Hybrid/Electric Heat Pump | 57 gal | 70 gal | 3.34 (-0.86) | 974 |
| [GE Profile PH50S10BPY01](https://gcsradheat.com/water-heaters/ge-profile/ph50s10bpy01/) | Hybrid/Electric Heat Pump | 50 gal | 77 gal | 4.3 (+0.10) | 1,154 |

## Which Home Setups Are NOT a Fit for LG APHWC502L?

Comparing LG APHWC502L against GREE GRS-3.0Pd/TD50GANhA-D requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- LG APHWC502L needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting LG APHWC502L directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing LG APHWC502L** Strong Fit — 4.2 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare GREE GRS-3.0Pd/TD50GANhA-D footprint.

## Common Homeowner Questions for LG APHWC502L

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does LG APHWC502L score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; LG APHWC502L logs 4.2 UEF (Pass: +1.90 / +82.6%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing LG APHWC502L?

With a 47.6 in. height and 19.7 in. diameter, LG APHWC502L fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (19.7" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits LG APHWC502L?

Powered via 240V at 24A max, LG APHWC502L requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for LG APHWC502L?

Annual electric spend for LG APHWC502L (1,181 kWh/yr) averages $214/yr nationwide (ranging from $173/yr in Washington hydro tiers up to $557/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing LG APHWC502L?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on LG APHWC502L.

### Is LG APHWC502L sized adequately for a 2-to-4-person household?

ENERGY STAR certifies LG APHWC502L at 81 gal First Hour Rating (+9 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does LG have active CPSC SaferProducts notices affecting APHWC502L?

Zero CPSC recall alerts matched LG (2026-11-23 check). Keep your LG APHWC502L serial code handy to track standard 6-to-12-year OEM warranty coverage.

### Which competing water heater matches LG APHWC502L (4.2 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for LG APHWC502L. Closest peer in Hybrid/Electric Heat Pump is GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF).

## Next Engineering Checks for LG Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare GREE GRS-3.0Pd/TD50GANhA-D (4.02 UEF)→](https://gcsradheat.com/water-heaters/gree/grs-3-0pd-td50ganha-d/)
- [Compare VAUGHN THERMAL MP55FHPT (3.3 UEF)→](https://gcsradheat.com/water-heaters/vaughn-thermal/mp55fhpt/)
- [View All LG Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/lg/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)