---
title: "Lochinvar CHPA-40 2** (3.6 UEF, 36 gal)"
url: https://gcsradheat.com/water-heaters/lochinvar/chpa-40-2/
description: "Certified at 3.6 UEF across its 36-gallon nominal tank, 55 gal First Hour Rating, Lochinvar CHPA-40 2** (Hybrid/Electric Heat Pump, Electric) places #401 of."
---

ENERGY STAR water heater model · PD 4689626

# Lochinvar CHPA-40 2** Water Heater Specifications (3.6 UEF)

Certified at 3.6 UEF across its 36-gallon nominal tank, 55 gal First Hour Rating, Lochinvar CHPA-40 2** (Hybrid/Electric Heat Pump, Electric) places #401 of 706 out of 706 ENERGY STAR models (PD 4689626). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.30 / +56.5%. Rated annual electricity draw of 902 kWh/yr equates to roughly $164/yr ($1,638 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith CAHP-40 2** (3.6 UEF).

- **Uniform Energy Factor**: 3.6 UEF

- **Cohort UEF Rank**: #401 of 706

- **First Hour Rating**: 55 gal

- **Storage Volume**: 36 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.30 / +56.5%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lochinvar CHPA-40 2** relative to the cohort median.

Efficiency comparison & rule summary

Tested at 3.6 UEF, Lochinvar CHPA-40 2** places #401 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.10 UEF vs. 3.70 UEF median).

Lochinvar CHPA-40 2** clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.30 UEF (+56.5% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 902 kWh/yr for Lochinvar CHPA-40 2** runs ~$164/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Lochinvar CHPA-40 2**: 10-year operating spend spans $1,320 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,256 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Lochinvar CHPA-40 2** include A. O. Smith CAHP-40 2** (3.6 UEF, at parity) alongside American HPA10240H045DV 2** (3.6 UEF, at parity).

## How Complete Are the Certified Metrics for Lochinvar CHPA-40 2**?

Standing at #401 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Lochinvar CHPA-40 2** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Lochinvar](https://gcsradheat.com/brands/lochinvar/) | 65 certified listings | ENERGY STAR PD 4689626 |
| Model Number | CHPA-40 2** | Draw pattern: Medium-Usage | CHPA-40 2** |
| Uniform Energy Factor (UEF) | 3.6 | -0.10 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 55 gal | -17 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 902 kWh/yr | -170 kWh/yr vs. 1,072 kWh/yr median | Est. $164/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 426% | -3.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 66" H x 20" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (20" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-08-13 | Certified 2026-08-13 | Markets: United States |

## What Is the Projected Utility Bill for CHPA-40 2** by State?

At 902 kWh/yr, Lochinvar CHPA-40 2** averages about $164/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $164/yr | $1,638 | $4,772 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $426/yr | $4,256 | $12,399 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $268/yr | $2,683 | $7,818 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $144/yr | $1,435 | $4,181 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $132/yr | $1,320 | $3,845 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (902 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are Lochinvar Models Affected by Current CPSC Notices?

Review 1 brand-matched CPSC entry pulled 2026-11-23 for Lochinvar and confirm your serial tag before scheduling contractor service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**1 Brand Recall Notice Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))

## Which 5 Models Offer Similar Output to CHPA-40 2**?

Ordered by minimal capacity and UEF spread relative to Lochinvar CHPA-40 2**, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith CAHP-40 2**](https://gcsradheat.com/water-heaters/a-o-smith/cahp-40-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (at parity) | 902 |
| [American HPA10240H045DV 2**](https://gcsradheat.com/water-heaters/american/hpa10240h045dv-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (at parity) | 902 |
| [RELIANCE WATER HEATERS 10-40-DHPTA 2**](https://gcsradheat.com/water-heaters/reliance-water-heaters/10-40-dhpta-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (at parity) | 902 |
| [State CSHP-40 2**](https://gcsradheat.com/water-heaters/state/cshp-40-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (at parity) | 902 |
| [A. O. Smith HPA10-40H45DV 2**](https://gcsradheat.com/water-heaters/a-o-smith/hpa10-40h45dv-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (at parity) | 902 |

## Who Is Lochinvar CHPA-40 2** Best For — and When Should You Pick A. O. Smith CAHP-40 2**?

Evaluate whether Lochinvar CHPA-40 2**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- Lochinvar CHPA-40 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Lochinvar CHPA-40 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Lochinvar CHPA-40 2 Strong Fit — 3.6 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith CAHP-40 2** footprint.

## Practical Specs & Code Questions for Lochinvar CHPA-40 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Lochinvar CHPA-40 2** (3.6 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Lochinvar CHPA-40 2** records 3.6 UEF (Pass: +1.30 / +56.5%), placing #401 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does Lochinvar CHPA-40 2** fit inside a tight hallway closet or low-headroom utility room?

Lochinvar CHPA-40 2** requires room for its 66 in. vertical shell and 20 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (20" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern Lochinvar CHPA-40 2**?

For Lochinvar CHPA-40 2**, plan a 240V circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for Lochinvar CHPA-40 2**?

Using 902 kWh/yr, Lochinvar CHPA-40 2** generates an estimated $164/yr electric bill at 18.16 cents/kWh (ranging from $132/yr in Washington hydro tiers up to $426/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of Lochinvar CHPA-40 2** (3.6 UEF)?

Lochinvar CHPA-40 2** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith CAHP-40 2**.

### What hot-water delivery rating governs Lochinvar CHPA-40 2**?

Rated for 55 gal FHR (-17 gal vs. 72 gal median), Lochinvar CHPA-40 2** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen Lochinvar CHPA-40 2** for recalls and tank age?

CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What alternative models sit closest to Lochinvar CHPA-40 2** in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is A. O. Smith CAHP-40 2** (3.6 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Installation, Serial & DOE 2029 Links for CHPA-40 2**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith CAHP-40 2** (3.6 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/cahp-40-2/)
- [Compare American HPA10240H045DV 2** (3.6 UEF)→](https://gcsradheat.com/water-heaters/american/hpa10240h045dv-2/)
- [View All Lochinvar Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/lochinvar/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)
