---
title: "Lochinvar HPV065KD 2** (3.2 UEF, 68 gal)"
url: https://gcsradheat.com/water-heaters/lochinvar/hpv065kd-2/
description: "The Lochinvar HPV065KD 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.2 UEF rating across its 68-gallon nominal tank, 76 gal First Hour."
---

ENERGY STAR water heater model · PD 2546250

# Lochinvar HPV065KD 2** Water Heater Specifications (3.2 UEF)

The Lochinvar HPV065KD 2** (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.2 UEF rating across its 68-gallon nominal tank, 76 gal First Hour Rating, ranking #646 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2546250). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.70 / +28.0%. Rated annual electricity draw of 1,550 kWh/yr equates to roughly $281/yr ($2,815 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPTV-66 2** (3.2 UEF).

- **Uniform Energy Factor**: 3.2 UEF

- **Cohort UEF Rank**: #646 of 706

- **First Hour Rating**: 76 gal

- **Storage Volume**: 68 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.70 / +28.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Lochinvar HPV065KD 2** relative to the cohort median.

Efficiency comparison & rule summary

Lochinvar HPV065KD 2** (3.2 UEF) ranks #646 of 706 Hybrid/Electric Heat Pump models — 8-way tie; more efficient than 7.5% of Hybrid/Electric Heat Pump models, -0.50 UEF below the 3.70 UEF median.

Federal 2029 margin for Lochinvar HPV065KD 2**: +0.70 UEF (+28.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,550 kWh/yr for Lochinvar HPV065KD 2** runs ~$281/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 45 dBA (quieter than 69.1% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Lochinvar HPV065KD 2**: 10-year operating spend spans $2,268 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $7,313 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Lochinvar HPV065KD 2** (3.2 UEF) compares closely with A. O. Smith HPTV-66 2** (3.2 UEF, at parity) and American HPV10266H009DV 2** (3.2 UEF, at parity).

## How Complete Are the Certified Metrics for Lochinvar HPV065KD 2**?

Standing at #646 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, Lochinvar HPV065KD 2** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Lochinvar](https://gcsradheat.com/brands/lochinvar/) | 65 certified listings | ENERGY STAR PD 2546250 |
| Model Number | HPV065KD 2** | Draw pattern: High-Usage | HPV065KD 2** |
| Uniform Energy Factor (UEF) | 3.2 | -0.50 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 76 gal | +4 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,550 kWh/yr | +478 kWh/yr vs. 1,072 kWh/yr median | Est. $281/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 368% | -61.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61" H x 23" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 15 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 45 dBA | top 30.9% · quieter than 69.1% of Hybrid/Electric Heat Pump models · -4 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |

## What Is the Projected Utility Bill for HPV065KD 2** by State?

At 1,550 kWh/yr, Lochinvar HPV065KD 2** averages about $281/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $281/yr | $2,815 | $6,975 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $731/yr | $7,313 | $18,122 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $461/yr | $4,611 | $11,427 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $247/yr | $2,466 | $6,111 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $227/yr | $2,268 | $5,619 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,550 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are Lochinvar Models Affected by Current CPSC Notices?

Review 1 brand-matched CPSC entry pulled 2026-11-23 for Lochinvar and confirm your serial tag before scheduling contractor service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**1 Brand Recall Notice Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))

## Which 5 Models Offer Similar Output to HPV065KD 2**?

Ordered by minimal capacity and UEF spread relative to Lochinvar HPV065KD 2**, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith HPTV-66 2**](https://gcsradheat.com/water-heaters/a-o-smith/hptv-66-2/) | Hybrid/Electric Heat Pump | 68 gal | 76 gal | 3.2 (at parity) | 1,550 |
| [American HPV10266H009DV 2**](https://gcsradheat.com/water-heaters/american/hpv10266h009dv-2/) | Hybrid/Electric Heat Pump | 68 gal | 76 gal | 3.2 (at parity) | 1,550 |
| [RELIANCE WATER HEATERS 10-66-DHPTV 2**](https://gcsradheat.com/water-heaters/reliance-water-heaters/10-66-dhptv-2/) | Hybrid/Electric Heat Pump | 68 gal | 76 gal | 3.2 (at parity) | 1,550 |
| [State HPVX-66-DHPT 2**](https://gcsradheat.com/water-heaters/state/hpvx-66-dhpt-2/) | Hybrid/Electric Heat Pump | 68 gal | 76 gal | 3.2 (at parity) | 1,550 |
| [A. O. Smith HPV10-66H01DV 2**](https://gcsradheat.com/water-heaters/a-o-smith/hpv10-66h01dv-2/) | Hybrid/Electric Heat Pump | 68 gal | 76 gal | 3.2 (at parity) | 1,550 |

## Which Home Setups Are NOT a Fit for Lochinvar HPV065KD 2**?

Comparing Lochinvar HPV065KD 2** against A. O. Smith HPTV-66 2** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- Lochinvar HPV065KD 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 45 dBA; avoid mounting Lochinvar HPV065KD 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Lochinvar HPV065KD 2 Strong Fit — 3.2 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith HPTV-66 2** footprint.

## Practical Specs & Code Questions for Lochinvar HPV065KD 2**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Lochinvar HPV065KD 2** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Lochinvar HPV065KD 2** logs 3.2 UEF (Pass: +0.70 / +28.0%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing Lochinvar HPV065KD 2**?

With a 61 in. height and 23 in. diameter, Lochinvar HPV065KD 2** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits Lochinvar HPV065KD 2**?

Powered via 120V at 15A max, Lochinvar HPV065KD 2** requires: 120V plug-in retrofit circuit; slower heat-pump-only recovery. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for Lochinvar HPV065KD 2**?

Annual electric spend for Lochinvar HPV065KD 2** (1,550 kWh/yr) averages $281/yr nationwide (ranging from $227/yr in Washington hydro tiers up to $731/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing Lochinvar HPV065KD 2**?

Homes lacking a condensate drain or 120V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Lochinvar HPV065KD 2**.

### Is Lochinvar HPV065KD 2** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Lochinvar HPV065KD 2** at 76 gal First Hour Rating (+4 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does Lochinvar have active CPSC SaferProducts notices affecting HPV065KD 2**?

CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### Which competing water heater matches Lochinvar HPV065KD 2** (3.2 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Lochinvar HPV065KD 2**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPTV-66 2** (3.2 UEF).

## Installation, Serial & DOE 2029 Links for HPV065KD 2**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith HPTV-66 2** (3.2 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hptv-66-2/)
- [Compare American HPV10266H009DV 2** (3.2 UEF)→](https://gcsradheat.com/water-heaters/american/hpv10266h009dv-2/)
- [View All Lochinvar Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/lochinvar/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)
