title: "MC Green A80-20 (99 SUEF, 80 gal) — TapAndPipe"
url: https://gcsradheat.com/water-heaters/mc-green/a80-20/
description: "Engineered as a Solar + Electric Backup Solar with Electric Backup unit, MC Green A80-20 achieves a certified 99.0 SUEF rating across its 80-gallon nominal."
---

ENERGY STAR water heater model · PD 2407842

# MC Green A80-20 Water Heater Specifications (99 SUEF)

Engineered as a Solar + Electric Backup Solar with Electric Backup unit, MC Green A80-20 achieves a certified 99.0 SUEF rating across its 80-gallon nominal tank and ranks #1 of 30 in its 30-model cohort (PD 2407842), recording Exempt — Solar SUEF under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is Acevedo Unit 2-20 (99.0 SUEF).

- **Solar UEF (SUEF)**: 99.0 SUEF

- **Cohort SUEF Rank**: #1 of 30 (top 40%)

- **First Hour Rating**: On-Demand

- **Storage Volume**: 80 gal

- **Fuel / Type**: Solar + Electric Backup / Solar with Electric Backup

- **DOE 2029 Rule Status**: Exempt — Solar SUEF

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Solar with Electric Backup SUEF Efficiency Distribution (30 Certified Units). Highlighted pin shows MC Green A80-20 relative to the cohort median.

Efficiency comparison & rule summary

Within the 30-unit Solar with Electric Backup cohort, MC Green A80-20 logs 99.0 SUEF and ranks #1 of 30.

Solar collector & storage profile, OG-300 #30004359 for MC Green A80-20: Direct Thermosyphon architecture; 18.1 sq ft Flat Plate collector; 80 gal storage tank; freeze limit 29 deg F.

Cross-shopping MC Green A80-20 (99.0 SUEF)? Check Acevedo Unit 2-20 (99.0 SUEF, at parity) and AET DX-80-64 (99.0 SUEF, at parity).

## How Complete Are the Certified Metrics for MC Green A80-20?

Standing at #1 of 30 (top 40%) among 30 certified Solar with Electric Backup heaters, MC Green A80-20 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 30 ENERGY STAR Solar with Electric Backup peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [MC Green](https://gcsradheat.com/brands/mc-green/) | 2 certified listings | ENERGY STAR PD 2407842 |
| Model Number | A80-20 | Draw pattern: Very-Small-Usage | A80-20 |
| Solar Uniform Energy Factor (SUEF) | 99.0 | +88.15 SUEF vs. 10.85 SUEF median | 10 CFR 430 Test Method |
| Solar System & Collector | Direct Thermosyphon (Flat Plate) | 18.1 sq ft aperture | OG-300 #30004359 |
| Collector Freeze Tolerance | 29 °F | SRCC freeze protection rating | ENERGY STAR Solar Dataset |
| Electrical Circuit Requirements | 240 V | Collector loop pump / controller + backup element check | NEC / Branch circuit check |
| Certification Date | 2021-09-14 | Certified 2021-09-14 | Markets: United States |

## Are MC Green Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched MC Green in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which 5 Models Offer Similar Output to A80-20?

Ordered by minimal capacity and SUEF spread relative to MC Green A80-20, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | SUEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Acevedo Unit 2-20](https://gcsradheat.com/water-heaters/acevedo/unit-2-20/) | Solar with Electric Backup | 80 gal | — | 99.0 (at parity) | — |
| [AET DX-80-64](https://gcsradheat.com/water-heaters/aet/dx-80-64/) | Solar with Electric Backup | 80 gal | — | 99.0 (at parity) | — |
| [Heliodyne HF 1 410 G 80 AC S E](https://gcsradheat.com/water-heaters/heliodyne/hf-1-410-g-80-ac-s-e/) | Solar with Electric Backup | 80 gal | — | 6.6 (-92.40) | — |
| [Rheem RS80-40BP](https://gcsradheat.com/water-heaters/rheem/rs80-40bp/) | Solar with Electric Backup | 80 gal | — | 4.8 (-94.20) | — |
| [Rheem RS80-48BP](https://gcsradheat.com/water-heaters/rheem/rs80-48bp/) | Solar with Electric Backup | 80 gal | — | 5.9 (-93.10) | — |

## When Should Homeowners Skip MC Green A80-20 (Solar with Electric Backup)?

Check MC Green A80-20's mechanical constraints—including utility space, Solar + Electric Backup capacity, and Exempt — Solar SUEF status—against typical residential installations.

### Key Limitations & Exclusions

- MC Green A80-20 logs 99.0 SUEF (Exempt — Solar SUEF); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect MC Green A80-20's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 80 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for MC Green A80-20** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Acevedo Unit 2-20.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Practical Specs & Code Questions for MC Green A80-20

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will MC Green A80-20 stay compliant after the May 6, 2029 DOE standard takes effect?

Rated at 99.0 SUEF, MC Green A80-20 uses SRCC solar collector physics exempt from the May 6, 2029 tank UEF rules, keeping it compliant alongside Acevedo Unit 2-20.

### Will MC Green A80-20 fit through a standard utility door and 72-inch basement ceiling?

Using a wall-mounted solar with electric backup chassis, MC Green A80-20 eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.

### Do existing utility hookups support MC Green A80-20 during replacement?

Electrical specs for MC Green A80-20 call for 240V (Collector loop pump / controller + backup element check). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for MC Green A80-20?

Because MC Green A80-20 burns Solar + Electric Backup at 99.0 SUEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 30 peers.

### When is MC Green A80-20 a poor fit for a residential replacement?

Avoid MC Green A80-20 if household peak demand surpasses 80 gal per hour or if state DOE HEAR incentives require >=2.30 UEF heat-pump equipment.

### What First Hour Rating or flow capacity does MC Green A80-20 deliver?

As an on-demand Solar with Electric Backup model, MC Green A80-20 has no tank depletion limit—verify GPM output at your state's 40–65 °F winter water rise.

### How do you verify manufacturing age and recall status on MC Green A80-20?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for MC Green; verify exact manufacturing week for MC Green A80-20 using the Serial Number Lookup tool.

### Does MC Green A80-20 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for MC Green A80-20. Closest peer in Solar with Electric Backup is Acevedo Unit 2-20 (99.0 SUEF).

## Installation, Serial & DOE 2029 Links for A80-20

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Acevedo Unit 2-20 (99.0 SUEF)→](https://gcsradheat.com/water-heaters/acevedo/unit-2-20/)
- [Compare AET DX-80-64 (99.0 SUEF)→](https://gcsradheat.com/water-heaters/aet/dx-80-64/)
- [View All MC Green Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/mc-green/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Check SRCC collector freeze protection, backup tank wiring, and available post-OBBBA state DOE HEAR / utility solar incentives before replacement.
[Check 2026 State Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Model Replacement Labor](https://gcsradheat.com/costs/water-heater-replacement/)