title: "Midea MAHW-65VN3B (4 UEF, 61 gal) — TapAndPipe"
url: https://gcsradheat.com/water-heaters/midea/mahw-65vn3b/
description: "The Midea MAHW-65VN3B (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.0 UEF rating across its 61-gallon nominal tank, 80 gal First Hour Rating."
---

ENERGY STAR water heater model · PD 4682185

# Midea MAHW-65VN3B Water Heater Specifications (4 UEF)

The Midea MAHW-65VN3B (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.0 UEF rating across its 61-gallon nominal tank, 80 gal First Hour Rating, ranking #106 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4682185). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.50 / +60.0%. Rated annual electricity draw of 1,234 kWh/yr equates to roughly $224/yr ($2,241 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rinnai REHP65CW* (4.0 UEF).

- **Uniform Energy Factor**: 4.0 UEF

- **Cohort UEF Rank**: #106 of 706 (top 19.8%)

- **First Hour Rating**: 80 gal

- **Storage Volume**: 61 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.50 / +60.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Midea MAHW-65VN3B relative to the cohort median.

Efficiency comparison & rule summary

Midea MAHW-65VN3B (4.0 UEF) ranks #106 of 706 Hybrid/Electric Heat Pump models — 35-way tie; top 19.8%, more efficient than 80.2% of Hybrid/Electric Heat Pump models, +0.30 UEF above the 3.70 UEF median.

Federal 2029 margin for Midea MAHW-65VN3B: +1.50 UEF (+60.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,234 kWh/yr for Midea MAHW-65VN3B runs ~$224/yr vs. ~$974/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Midea MAHW-65VN3B: 10-year operating spend spans $1,805 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,822 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Midea MAHW-65VN3B (4.0 UEF) compares closely with Rinnai REHP65CW* (4.0 UEF, at parity) and Navien NWP500S065AUMB (4.03 UEF, delta +0.03).

## How Do Midea MAHW-65VN3B Specs Compare to Hybrid/Electric Heat Pump Medians?

Midea MAHW-65VN3B places #106 of 706 (top 19.8%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Midea](https://gcsradheat.com/brands/midea/) | 49 certified listings | ENERGY STAR PD 4682185 |
| Model Number | MAHW-65VN3B | Draw pattern: High-Usage | MAHW-65VN3B |
| Uniform Energy Factor (UEF) | 4.0 | +0.30 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 80 gal | +8 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,234 kWh/yr | +162 kWh/yr vs. 1,072 kWh/yr median | Est. $224/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 450% | +21.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 45.5" H x 21.8" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2026-07-31 | Certified 2026-07-31 | Markets: United States, Canada |

## What Does MAHW-65VN3B Cost to Operate Across State Electricity Rates?

At 1,234 kWh/yr, Midea MAHW-65VN3B runs roughly $224/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $224/yr | $2,241 | $7,502 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $582/yr | $5,822 | $19,490 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $367/yr | $3,671 | $12,290 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $196/yr | $1,963 | $6,572 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $181/yr | $1,805 | $6,044 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,234 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for Midea Water Heaters?

Zero active CPSC recalls matched Midea in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Certified Water Heaters Match MAHW-65VN3B Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Midea MAHW-65VN3B by storage capacity and 4.0 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Rinnai REHP65CW*](https://gcsradheat.com/water-heaters/rinnai/rehp65cw/) | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.0 (at parity) | 1,234 |
| [Navien NWP500S065AUMB](https://gcsradheat.com/water-heaters/navien/nwp500s065aumb/) | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.03 (+0.03) | 1,245 |
| [Ariston ARIHPWH-65-T](https://gcsradheat.com/water-heaters/ariston/arihpwh-65-t/) | Hybrid/Electric Heat Pump | 61 gal | 77 gal | 4.05 (+0.05) | 1,225 |
| [Lennox WHHP065T45MD240S](https://gcsradheat.com/water-heaters/lennox/whhp065t45md240s/) | Hybrid/Electric Heat Pump | 61 gal | 77 gal | 4.05 (+0.05) | 1,225 |
| [Rinnai REHP65W*](https://gcsradheat.com/water-heaters/rinnai/rehp65w/) | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.0 (at parity) | 1,234 |

## What Are the Limitations of Midea MAHW-65VN3B and Who Should Not Install It?

Before ordering Midea MAHW-65VN3B (Hybrid/Electric Heat Pump, 4.0 UEF), weigh space clearances, fuel piping, noise (49 dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- Midea MAHW-65VN3B needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Midea MAHW-65VN3B directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Midea MAHW-65VN3B** Strong Fit — 4.0 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Rinnai REHP65CW* footprint.

## What Are the Key Questions About Midea MAHW-65VN3B?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Midea MAHW-65VN3B pass the May 6, 2029 federal DOE efficiency rule?

Midea MAHW-65VN3B carries a verified 4.0 UEF rating (Pass: +1.50 / +60.0%), ranking #106 of 706 (top 19.8%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

### What doorway width and ceiling height does Midea MAHW-65VN3B need?

Midea MAHW-65VN3B stands 45.5 in. high with a 21.8 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does Midea MAHW-65VN3B require?

Midea MAHW-65VN3B uses a 240V branch circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

### How much electricity or energy does Midea MAHW-65VN3B cost per year to run?

Rated at 1,234 kWh/yr, Midea MAHW-65VN3B costs about $224/yr ($2,240 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $181/yr in Washington hydro tiers up to $582/yr in Hawaii).

### Who should NOT install Midea MAHW-65VN3B, and what are its limits?

Midea MAHW-65VN3B (4.0 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

### How many bathrooms or people can Midea MAHW-65VN3B serve at peak demand?

Midea MAHW-65VN3B achieves a 80 gal First Hour Rating (+8 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for Midea MAHW-65VN3B?

No active CPSC recalls matched Midea as of 2026-11-23. Always decode the serial tag on Midea MAHW-65VN3B because OEM tank/exchanger warranties span 6–12 years.

### What 2026 rebates apply to Midea MAHW-65VN3B, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Rinnai REHP65CW* (4.0 UEF).

## Which Sizing and Compliance Guides Pair with MAHW-65VN3B?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Rinnai REHP65CW* (4.0 UEF)→](https://gcsradheat.com/water-heaters/rinnai/rehp65cw/)
- [Compare Navien NWP500S065AUMB (4.03 UEF)→](https://gcsradheat.com/water-heaters/navien/nwp500s065aumb/)
- [View All Midea Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/midea/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)