title: "Midea MCHW-50VN3B (3.75 UEF, 46 gal)"
url: https://gcsradheat.com/water-heaters/midea/mchw-50vn3b/
description: "Certified at 3.75 UEF across its 46-gallon nominal tank, 71 gal First Hour Rating, Midea MCHW-50VN3B (Hybrid/Electric Heat Pump, Electric) places #297 of 706."
---

ENERGY STAR water heater model · PD 4682186

# Midea MCHW-50VN3B Water Heater Specifications (3.75 UEF)

Certified at 3.75 UEF across its 46-gallon nominal tank, 71 gal First Hour Rating, Midea MCHW-50VN3B (Hybrid/Electric Heat Pump, Electric) places #297 of 706 out of 706 ENERGY STAR models (PD 4682186). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.45 / +63.0%. Rated annual electricity draw of 861 kWh/yr equates to roughly $156/yr ($1,564 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rinnai REHP50CW (3.75 UEF).

- **Uniform Energy Factor**: 3.75 UEF

- **Cohort UEF Rank**: #297 of 706

- **First Hour Rating**: 71 gal

- **Storage Volume**: 46 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.45 / +63.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Midea MCHW-50VN3B relative to the cohort median.

Efficiency comparison & rule summary

Tested at 3.75 UEF, Midea MCHW-50VN3B places #297 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.05 UEF vs. 3.70 UEF median).

Midea MCHW-50VN3B clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.45 UEF (+63.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 861 kWh/yr for Midea MCHW-50VN3B runs ~$156/yr vs. ~$637/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Midea MCHW-50VN3B: 10-year operating spend spans $1,260 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,062 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Midea MCHW-50VN3B include Rinnai REHP50CW (3.75 UEF, at parity) alongside A. O. Smith HPS10-50H45DV 2** (3.8 UEF, delta +0.05).

## What Physical and Thermal Ratings Define Midea MCHW-50VN3B?

Positioning at #297 of 706 out of 706 Hybrid/Electric Heat Pump peers, Midea MCHW-50VN3B pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Midea](https://gcsradheat.com/brands/midea/) | 49 certified listings | ENERGY STAR PD 4682186 |
| Model Number | MCHW-50VN3B | Draw pattern: Medium-Usage | MCHW-50VN3B |
| Uniform Energy Factor (UEF) | 3.75 | +0.05 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 71 gal | -1 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 861 kWh/yr | -211 kWh/yr vs. 1,072 kWh/yr median | Est. $156/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 420% | -9.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 46.6" H x 18.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2026-07-31 | Certified 2026-07-31 | Markets: United States, Canada |

## Why Do State Utility Rates Shift MCHW-50VN3B Running Costs?

Consuming 861 kWh annually puts Midea MCHW-50VN3B near $156/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $156/yr | $1,564 | $4,811 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $406/yr | $4,062 | $12,498 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $256/yr | $2,561 | $7,881 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $137/yr | $1,370 | $4,215 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $126/yr | $1,260 | $3,875 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (861 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any Midea Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Midea; confirm tank age separately using the rating-plate serial pattern. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## What Are 5 Direct Alternatives to Midea MCHW-50VN3B?

Homeowners cross-shopping Midea MCHW-50VN3B frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Rinnai REHP50CW](https://gcsradheat.com/water-heaters/rinnai/rehp50cw/) | Hybrid/Electric Heat Pump | 46 gal | 71 gal | 3.75 (at parity) | 861 |
| [A. O. Smith HPS10-50H45DV 2**](https://gcsradheat.com/water-heaters/a-o-smith/hps10-50h45dv-2/) | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (+0.05) | 831 |
| [American HPS10250H045DV 2**](https://gcsradheat.com/water-heaters/american/hps10250h045dv-2/) | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (+0.05) | 831 |
| [Lochinvar HPSA050KD 2**](https://gcsradheat.com/water-heaters/lochinvar/hpsa050kd-2/) | Hybrid/Electric Heat Pump | 46 gal | 65 gal | 3.8 (+0.05) | 831 |
| [Rinnai REHP50W](https://gcsradheat.com/water-heaters/rinnai/rehp50w/) | Hybrid/Electric Heat Pump | 46 gal | 71 gal | 3.75 (at parity) | 861 |

## Who Is Midea MCHW-50VN3B Best For — and When Should You Pick Rinnai REHP50CW?

Evaluate whether Midea MCHW-50VN3B's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- Midea MCHW-50VN3B needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Midea MCHW-50VN3B directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Midea MCHW-50VN3B** Strong Fit — 3.75 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Rinnai REHP50CW footprint.

## Sizing, Efficiency & Recall Answers for Midea MCHW-50VN3B

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Midea MCHW-50VN3B (3.75 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Midea MCHW-50VN3B records 3.75 UEF (Pass: +1.45 / +63.0%), placing #297 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does Midea MCHW-50VN3B fit inside a tight hallway closet or low-headroom utility room?

Midea MCHW-50VN3B requires room for its 46.6 in. vertical shell and 18.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.3" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern Midea MCHW-50VN3B?

For Midea MCHW-50VN3B, plan a 240V circuit at 24A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for Midea MCHW-50VN3B?

Using 861 kWh/yr, Midea MCHW-50VN3B generates an estimated $156/yr electric bill at 18.16 cents/kWh (ranging from $126/yr in Washington hydro tiers up to $406/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of Midea MCHW-50VN3B (3.75 UEF)?

Midea MCHW-50VN3B requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Rinnai REHP50CW.

### What hot-water delivery rating governs Midea MCHW-50VN3B?

Rated for 71 gal FHR (-1 gal vs. 72 gal median), Midea MCHW-50VN3B prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen Midea MCHW-50VN3B for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Midea; use our browser-only serial decoder to inspect Midea MCHW-50VN3B's age and warranty window.

### What alternative models sit closest to Midea MCHW-50VN3B in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Rinnai REHP50CW (3.75 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Related Rebate, Gas-Line & Serial Tools for MCHW-50VN3B

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Rinnai REHP50CW (3.75 UEF)→](https://gcsradheat.com/water-heaters/rinnai/rehp50cw/)
- [Compare A. O. Smith HPS10-50H45DV 2** (3.8 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hps10-50h45dv-2/)
- [View All Midea Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/midea/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)