title: "Midea MCHW-80VN3A (4 UEF, 74 gal) — TapAndPipe"
url: https://gcsradheat.com/water-heaters/midea/mchw-80vn3a/
description: "The Midea MCHW-80VN3A (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.0 UEF rating across its 74-gallon nominal tank, 91 gal First Hour Rating."
---

ENERGY STAR water heater model · PD 3624380

# Midea MCHW-80VN3A Water Heater Specifications (4 UEF)

The Midea MCHW-80VN3A (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.0 UEF rating across its 74-gallon nominal tank, 91 gal First Hour Rating, ranking #106 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3624380). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.50 / +60.0%. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).

- **Uniform Energy Factor**: 4.0 UEF

- **Cohort UEF Rank**: #106 of 706 (top 19.8%)

- **First Hour Rating**: 91 gal

- **Storage Volume**: 74 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.50 / +60.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Midea MCHW-80VN3A relative to the cohort median.

Efficiency comparison & rule summary

Midea MCHW-80VN3A (4.0 UEF) ranks #106 of 706 Hybrid/Electric Heat Pump models — 35-way tie; top 19.8%, more efficient than 80.2% of Hybrid/Electric Heat Pump models, +0.30 UEF above the 3.70 UEF median.

Federal 2029 margin for Midea MCHW-80VN3A: +1.50 UEF (+60.0%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for Midea MCHW-80VN3A runs ~$225/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Midea MCHW-80VN3A: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Midea MCHW-80VN3A (4.0 UEF) compares closely with 1HVAC ACIQ-80G-HP-WH (4.0 UEF, at parity) and ACIQ ACIQ-80G-HP-WH (4.0 UEF, at parity).

## How Do Midea MCHW-80VN3A Specs Compare to Hybrid/Electric Heat Pump Medians?

Midea MCHW-80VN3A places #106 of 706 (top 19.8%) across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Midea](https://gcsradheat.com/brands/midea/) | 49 certified listings | ENERGY STAR PD 3624380 |
| Model Number | MCHW-80VN3A | Draw pattern: High-Usage | MCHW-80VN3A |
| Uniform Energy Factor (UEF) | 4.0 | +0.30 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 91 gal | +19 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,240 kWh/yr | +168 kWh/yr vs. 1,072 kWh/yr median | Est. $225/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 450% | +21.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 41.7" H x 21.8" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2024-11-04 | Certified 2024-11-04 | Markets: United States, Canada |

## What Does MCHW-80VN3A Cost to Operate Across State Electricity Rates?

At 1,240 kWh/yr, Midea MCHW-80VN3A runs roughly $225/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $225/yr | $2,252 | $7,538 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $585/yr | $5,850 | $19,584 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $369/yr | $3,689 | $12,349 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $197/yr | $1,973 | $6,604 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $181/yr | $1,814 | $6,073 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,240 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for Midea Water Heaters?

Zero active CPSC recalls matched Midea in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Certified Water Heaters Match MCHW-80VN3A Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Midea MCHW-80VN3A by storage capacity and 4.0 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [1HVAC ACIQ-80G-HP-WH](https://gcsradheat.com/water-heaters/1hvac/aciq-80g-hp-wh/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| [ACIQ ACIQ-80G-HP-WH](https://gcsradheat.com/water-heaters/aciq/aciq-80g-hp-wh/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| [Bosch TR7000T - 80CA](https://gcsradheat.com/water-heaters/bosch/tr7000t-80ca/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| [Custom Comfort CCOHPWH80A](https://gcsradheat.com/water-heaters/custom-comfort/ccohpwh80a/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| [Bosch TR7000T - 80US](https://gcsradheat.com/water-heaters/bosch/tr7000t-80us/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |

## What Installation Caveats Apply Before Buying Midea MCHW-80VN3A?

Even high-UEF units like Midea MCHW-80VN3A (4.0 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Midea MCHW-80VN3A needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Midea MCHW-80VN3A directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Midea MCHW-80VN3A** Strong Fit — 4.0 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare 1HVAC ACIQ-80G-HP-WH footprint.

## What Are the Key Questions About Midea MCHW-80VN3A?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Midea MCHW-80VN3A eligible for continued manufacture past May 6, 2029?

At 4.0 UEF, Midea MCHW-80VN3A achieves Pass: +1.50 / +60.0% for the 2029 DOE standard and stands #106 of 706 (top 19.8%) against 1HVAC ACIQ-80G-HP-WH and ACIQ ACIQ-80G-HP-WH.

### How tall and wide is Midea MCHW-80VN3A, and what service clearance is needed?

Physical dimensions for Midea MCHW-80VN3A are 41.7 in. height and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)); verify stair turns and drain pan width before delivery.

### Will Midea MCHW-80VN3A require upgrading household electrical panels or gas piping?

Midea MCHW-80VN3A draws 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is Midea MCHW-80VN3A economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $225/yr ($2,250 over 10 years) to power Midea MCHW-80VN3A at 1,240 kWh/yr under the 18.16 cents/kWh US average (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii).

### Which installation bottlenecks limit Midea MCHW-80VN3A?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Midea MCHW-80VN3A drops into resistance mode more often.

### How does Midea MCHW-80VN3A handle simultaneous showers and laundry?

Delivering 91 gal in the first hour (+19 gal vs. 72 gal median), Midea MCHW-80VN3A combines 74 gal tank storage with rapid burner/element recovery.

### How long is the warranty on Midea MCHW-80VN3A and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Midea as of 2026-11-23. Confirm install proof and serial manufacture year on Midea MCHW-80VN3A before calling service.

### How do 2026 post-OBBBA rebates affect buying Midea MCHW-80VN3A?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).

## Which Sizing and Compliance Guides Pair with MCHW-80VN3A?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare 1HVAC ACIQ-80G-HP-WH (4.0 UEF)→](https://gcsradheat.com/water-heaters/1hvac/aciq-80g-hp-wh/)
- [Compare ACIQ ACIQ-80G-HP-WH (4.0 UEF)→](https://gcsradheat.com/water-heaters/aciq/aciq-80g-hp-wh/)
- [View All Midea Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/midea/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)