title: "Navien NPE-210A2 (0.95 UEF, Gas Tankless)"
url: https://gcsradheat.com/water-heaters/navien/npe-210a2/
description: "In the 464-unit Gas Tankless class, Navien NPE-210A2 (Natural Gas, Propane) achieves a certified 0.95 UEF rating (rank #159 of 464, PD 2408694) and verifies as."
---

ENERGY STAR water heater model · PD 2408694

# Navien NPE-210A2 Water Heater Specifications (0.95 UEF)

In the 464-unit Gas Tankless class, Navien NPE-210A2 (Natural Gas, Propane) achieves a certified 0.95 UEF rating (rank #159 of 464, PD 2408694) and verifies as Pass: +0.04 / +4.4% for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

- **Uniform Energy Factor**: 0.95 UEF

- **Cohort UEF Rank**: #159 of 464

- **First Hour Rating**: On-Demand

- **Storage Volume**: Tankless

- **Fuel / Type**: Natural Gas, Propane / Gas Tankless

- **DOE 2029 Rule Status**: Pass: +0.04 / +4.4%

Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils

Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Navien NPE-210A2 relative to the cohort median.

Efficiency comparison & rule summary

Navien NPE-210A2 records 0.95 UEF efficiency, putting it #159 of 464 among 464 Gas Tankless peers.

DOE 2029 compliance check: Navien NPE-210A2 sits +0.04 UEF (+4.4%) above 0.91 UEF.

Competing options beside Navien NPE-210A2 (0.95 UEF) are A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) and American GT-240-NEH 1** (0.95 UEF, at parity).

## How Complete Are the Certified Metrics for Navien NPE-210A2?

Standing at #159 of 464 among 464 certified Gas Tankless heaters, Navien NPE-210A2 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Navien](https://gcsradheat.com/brands/navien/) | 9 certified listings | ENERGY STAR PD 2408694 |
| Model Number | NPE-210A2 | Draw pattern: High-Usage | NPE-210A2 |
| Uniform Energy Factor (UEF) | 0.95 | At 0.95 UEF median | 10 CFR 430 Test Method |
| Electrical Circuit Requirements | 2 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are Navien Models Affected by Current CPSC Notices?

Review 2 brand-matched CPSC entries pulled 2026-11-23 for Navien and confirm your serial tag before scheduling contractor service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19057 (2018-12-20):** Navien Recalls Tankless Water Heaters and Boilers Due to Risk of Carbon Monoxide Poisoning ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/Navien-Recalls-Tankless-Water-Heaters-and-Boilers-Due-to-Risk-of-Carbon-Monoxide-Poisoning))
- **Recall #12074 (2011-12-27):** Navien Recalls Tankless Water Heaters Due to Risk of Carbon Monoxide Poisoning ([CPSC Notice](https://www.cpsc.gov/Recalls/2012/Navien-Recalls-Tankless-Water-Heaters-Due-to-Risk-of-Carbon-Monoxide-Poisoning))

## Which 5 Models Offer Similar Output to NPE-210A2?

Ordered by minimal capacity and UEF spread relative to Navien NPE-210A2, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith ACT-199O-N 1**](https://gcsradheat.com/water-heaters/a-o-smith/act-199o-n-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [American GT-240-NEH 1**](https://gcsradheat.com/water-heaters/american/gt-240-neh-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [Bosch T9800 SE 160](https://gcsradheat.com/water-heaters/bosch/t9800-se-160/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [Bradford White RTG-K-160N1](https://gcsradheat.com/water-heaters/bradford-white/rtg-k-160n1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [A. O. Smith ACT-199O-P 1*1](https://gcsradheat.com/water-heaters/a-o-smith/act-199o-p-1-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |

## What Are the Limitations of Navien NPE-210A2 and Who Should Not Install It?

Before ordering Navien NPE-210A2 (Gas Tankless, 0.95 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- Converting a 40K tank to Navien NPE-210A2 often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
- Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Navien NPE-210A2's heat exchanger.
- Condensing Navien NPE-210A2 requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

### Which Option Fits Your Situation?

**Existing 3/4 in.+ Gas Line + Marathon Hot Draws** Strong Fit — Navien NPE-210A2 delivers continuous 0.95 UEF performance.

**Softened/Low-Scale Water (<7.0 GPG)** Strong Fit — Minimal calcium scale between 12-month flushes.

**Long 1/2 in. Gas Run (>10 ft)** Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

## Practical Specs & Code Questions for Navien NPE-210A2

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Navien NPE-210A2 pass the May 6, 2029 federal DOE efficiency rule?

Navien NPE-210A2 carries a verified 0.95 UEF rating (Pass: +0.04 / +4.4%), ranking #159 of 464 across 464 ENERGY STAR Gas Tankless models under 10 CFR 430.32.

### What doorway width and ceiling height does Navien NPE-210A2 need?

Navien NPE-210A2 mounts as a gas tankless without a bulky floor tank (wall-hung / compact envelope). Verify vent termination distances and combustion air clearances per IPC or UPC.

### What gas pipe size or electrical breaker does Navien NPE-210A2 require?

Navien NPE-210A2 runs on Natural Gas, Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

### How much electricity or energy does Navien NPE-210A2 cost per year to run?

ENERGY STAR rates Navien NPE-210A2 as a Natural Gas, Propane heater (0.95 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas Tankless draw.

### Who should NOT install Navien NPE-210A2, and what are its limits?

Navien NPE-210A2 (0.95 UEF) is rarely a drop-in swap over a 40K tank if existing 1/2 in. gas pipe cannot supply 199,000 BTU/h or hardness exceeds 7.0 GPG without descaling.

### How many bathrooms or people can Navien NPE-210A2 serve at peak demand?

Navien NPE-210A2 provides continuous Gas Tankless delivery rather than a fixed storage FHR; size GPM flow against winter incoming groundwater temperature and 2.0 GPM showers.

### Are there CPSC safety recalls or serial checks for Navien NPE-210A2?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Navien as of 2026-11-23, including #19057 (2018-12-20). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What 2026 rebates apply to Navien NPE-210A2, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

## Installation, Serial & DOE 2029 Links for NPE-210A2

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith ACT-199O-N 1** (0.95 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/act-199o-n-1/)
- [Compare American GT-240-NEH 1** (0.95 UEF)→](https://gcsradheat.com/water-heaters/american/gt-240-neh-1/)
- [View All Navien Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/navien/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)