title: "Navien NWP500S050AUMB (3.85 UEF, 44 gal)"
url: https://gcsradheat.com/water-heaters/navien/nwp500s050aumb/
description: "With PD 4015938 certification, Navien NWP500S050AUMB (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.85 UEF rating across its 44-gallon nominal."
---

ENERGY STAR water heater model · PD 4015938

# Navien NWP500S050AUMB Water Heater Specifications (3.85 UEF)

With PD 4015938 certification, Navien NWP500S050AUMB (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.85 UEF rating across its 44-gallon nominal tank, 65 gal First Hour Rating, standing #217 of 706 across 706 peers with Pass: +1.55 / +67.4% for May 6, 2029. Rated annual electricity draw of 840 kWh/yr equates to roughly $153/yr ($1,525 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Arctic Arctic-HP-Hot Water-KA06-50 (3.88 UEF).

- **Uniform Energy Factor**: 3.85 UEF

- **Cohort UEF Rank**: #217 of 706 (top 31.2%)

- **First Hour Rating**: 65 gal

- **Storage Volume**: 44 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.55 / +67.4%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Navien NWP500S050AUMB relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places Navien NWP500S050AUMB at 3.85 UEF (#217 of 706; +0.15 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Navien NWP500S050AUMB stands +1.55 UEF (+67.4%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 840 kWh/yr for Navien NWP500S050AUMB runs ~$153/yr vs. ~$638/yr for a 0.92 UEF electric tank.

State electric sensitivity for Navien NWP500S050AUMB: 10-year operating spend spans $1,229 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,963 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Arctic Arctic-HP-Hot Water-KA06-50 (3.88 UEF, delta +0.03) and PHNIX KA06-50 (3.88 UEF, delta +0.03) bracket Navien NWP500S050AUMB.

## Which Specs Set Navien NWP500S050AUMB Apart From Cohort Averages?

Ranked #217 of 706 (top 31.2%) inside the 706-model Hybrid/Electric Heat Pump cohort, Navien NWP500S050AUMB is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Navien](https://gcsradheat.com/brands/navien/) | 9 certified listings | ENERGY STAR PD 4015938 |
| Model Number | NWP500S050AUMB | Draw pattern: Medium-Usage | NWP500S050AUMB |
| Uniform Energy Factor (UEF) | 3.85 | +0.15 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 65 gal | -7 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 840 kWh/yr | -232 kWh/yr vs. 1,072 kWh/yr median | Est. $153/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 461% | +32.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 63" H x 21.8" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2025-04-21 | Certified 2025-04-21 | Markets: United States, Canada |

## How Do Regional kWh Prices Impact NWP500S050AUMB Over 10 Years?

Using EIA Table 5.6.A benchmarks, Navien NWP500S050AUMB's 840 kWh/yr draw translates to roughly $153/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $153/yr | $1,525 | $4,858 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $396/yr | $3,963 | $12,621 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $250/yr | $2,499 | $7,958 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $134/yr | $1,336 | $4,256 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $123/yr | $1,229 | $3,914 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (840 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should Navien Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 2 filings tied to Navien; verify whether your NWP500S050AUMB production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19057 (2018-12-20):** Navien Recalls Tankless Water Heaters and Boilers Due to Risk of Carbon Monoxide Poisoning ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/Navien-Recalls-Tankless-Water-Heaters-and-Boilers-Due-to-Risk-of-Carbon-Monoxide-Poisoning))
- **Recall #12074 (2011-12-27):** Navien Recalls Tankless Water Heaters Due to Risk of Carbon Monoxide Poisoning ([CPSC Notice](https://www.cpsc.gov/Recalls/2012/Navien-Recalls-Tankless-Water-Heaters-Due-to-Risk-of-Carbon-Monoxide-Poisoning))

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Arctic Arctic-HP-Hot Water-KA06-50](https://gcsradheat.com/water-heaters/arctic/arctic-hp-hot-water-ka06-50/) | Hybrid/Electric Heat Pump | 44.5 gal | 65 gal | 3.88 (+0.03) | 837 |
| [PHNIX KA06-50](https://gcsradheat.com/water-heaters/phnix/ka06-50/) | Hybrid/Electric Heat Pump | 44.5 gal | 65 gal | 3.88 (+0.03) | 837 |
| [Noritz NHP-50-240](https://gcsradheat.com/water-heaters/noritz/nhp-50-240/) | Hybrid/Electric Heat Pump | 45 gal | 68 gal | 3.85 (at parity) | 844 |
| [Ariston ARIHPWH-50-T](https://gcsradheat.com/water-heaters/ariston/arihpwh-50-t/) | Hybrid/Electric Heat Pump | 45 gal | 69 gal | 3.83 (-0.02) | 848 |
| [Lennox WHHP050T45MD240S](https://gcsradheat.com/water-heaters/lennox/whhp050t45md240s/) | Hybrid/Electric Heat Pump | 45 gal | 69 gal | 3.83 (-0.02) | 848 |

## What Installation Caveats Apply Before Buying Navien NWP500S050AUMB?

Even high-UEF units like Navien NWP500S050AUMB (3.85 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Navien NWP500S050AUMB needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Navien NWP500S050AUMB directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Navien NWP500S050AUMB** Strong Fit — 3.85 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Arctic Arctic-HP-Hot Water-KA06-50 footprint.

## Frequently Asked Technical Questions: Navien NWP500S050AUMB

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Navien NWP500S050AUMB eligible for continued manufacture past May 6, 2029?

At 3.85 UEF, Navien NWP500S050AUMB achieves Pass: +1.55 / +67.4% for the 2029 DOE standard and stands #217 of 706 (top 31.2%) against Arctic Arctic-HP-Hot Water-KA06-50 and PHNIX KA06-50.

### How tall and wide is Navien NWP500S050AUMB, and what service clearance is needed?

Physical dimensions for Navien NWP500S050AUMB are 63 in. height and 21.8 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d)); verify stair turns and drain pan width before delivery.

### Will Navien NWP500S050AUMB require upgrading household electrical panels or gas piping?

Navien NWP500S050AUMB draws 240V at 23A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is Navien NWP500S050AUMB economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $153/yr ($1,530 over 10 years) to power Navien NWP500S050AUMB at 840 kWh/yr under the 18.16 cents/kWh US average (ranging from $123/yr in Washington hydro tiers up to $396/yr in Hawaii).

### Which installation bottlenecks limit Navien NWP500S050AUMB?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Navien NWP500S050AUMB drops into resistance mode more often.

### How does Navien NWP500S050AUMB handle simultaneous showers and laundry?

Delivering 65 gal in the first hour (-7 gal vs. 72 gal median), Navien NWP500S050AUMB combines 44 gal tank storage with rapid burner/element recovery.

### How long is the warranty on Navien NWP500S050AUMB and how do you decode its serial?

CPSC SaferProducts records show 2 brand-level recall notices mentioning Navien as of 2026-11-23, including #19057 (2018-12-20). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### How do 2026 post-OBBBA rebates affect buying Navien NWP500S050AUMB?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Arctic Arctic-HP-Hot Water-KA06-50 (3.88 UEF).

## Essential Pre-Install Guides for Navien NWP500S050AUMB

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Arctic Arctic-HP-Hot Water-KA06-50 (3.88 UEF)→](https://gcsradheat.com/water-heaters/arctic/arctic-hp-hot-water-ka06-50/)
- [Compare PHNIX KA06-50 (3.88 UEF)→](https://gcsradheat.com/water-heaters/phnix/ka06-50/)
- [View All Navien Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/navien/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)