# Noritz NHP-50-240 Water Heater Specifications (3.85 UEF)

The Noritz NHP-50-240 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.85 UEF rating across its 45-gallon nominal tank, 68 gal First Hour Rating, ranking #217 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 4724095). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.55 / +67.4%. Rated annual electricity draw of 844 kWh/yr equates to roughly $153/yr ($1,533 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Ariston ARIHPWH-50-T (3.83 UEF).

- **Uniform Energy Factor**: 3.85 UEF

- **Cohort UEF Rank**: #217 of 706 (top 31.2%)

- **First Hour Rating**: 68 gal

- **Storage Volume**: 45 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.55 / +67.4%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Noritz NHP-50-240 relative to the cohort median.

Efficiency comparison & rule summary

Noritz NHP-50-240 (3.85 UEF) ranks #217 of 706 Hybrid/Electric Heat Pump models — 4-way tie; top 31.2%, more efficient than 68.8% of Hybrid/Electric Heat Pump models, +0.15 UEF above the 3.70 UEF median.

Federal 2029 margin for Noritz NHP-50-240: +1.55 UEF (+67.4%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 844 kWh/yr for Noritz NHP-50-240 runs ~$153/yr vs. ~$641/yr for a 0.92 UEF electric tank. Acoustic output is 48 dBA (quieter than 67.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for Noritz NHP-50-240: 10-year operating spend spans $1,235 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,982 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Noritz NHP-50-240 (3.85 UEF) compares closely with Ariston ARIHPWH-50-T (3.83 UEF, delta -0.02) and Lennox WHHP050T45MD240S (3.83 UEF, delta -0.02).

## What Physical and Thermal Ratings Define Noritz NHP-50-240?

Positioning at #217 of 706 (top 31.2%) out of 706 Hybrid/Electric Heat Pump peers, Noritz NHP-50-240 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Noritz](https://gcsradheat.com/brands/noritz/) | 23 certified listings | ENERGY STAR PD 4724095 |
| Model Number | NHP-50-240 | Draw pattern: Medium-Usage | NHP-50-240 |
| Uniform Energy Factor (UEF) | 3.85 | +0.15 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 68 gal | -4 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 844 kWh/yr | -228 kWh/yr vs. 1,072 kWh/yr median | Est. $153/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 438% | +9.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61.4" H x 22" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21.3 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 48 dBA | top 32.2% · quieter than 67.8% of Hybrid/Electric Heat Pump models · -1 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2026-10-30 | Certified 2026-10-30 | Markets: United States, Canada |

## Why Do State Utility Rates Shift NHP-50-240 Running Costs?

Consuming 844 kWh annually puts Noritz NHP-50-240 near $153/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $153/yr | $1,533 | $4,881 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $398/yr | $3,982 | $12,682 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $251/yr | $2,511 | $7,997 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $134/yr | $1,343 | $4,277 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $123/yr | $1,235 | $3,933 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (844 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any Noritz Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Noritz; confirm tank age separately using the rating-plate serial pattern. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## What Are 5 Direct Alternatives to Noritz NHP-50-240?

Homeowners cross-shopping Noritz NHP-50-240 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Ariston ARIHPWH-50-T](https://gcsradheat.com/water-heaters/ariston/arihpwh-50-t/) | Hybrid/Electric Heat Pump | 45 gal | 69 gal | 3.83 (-0.02) | 848 |
| [Lennox WHHP050T45MD240S](https://gcsradheat.com/water-heaters/lennox/whhp050t45md240s/) | Hybrid/Electric Heat Pump | 45 gal | 69 gal | 3.83 (-0.02) | 848 |
| [Friedrich PROH50 T2 FD400-30](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd400-30/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (+0.03) | 846 |
| [Rheem CPROPH50 T2 RH375-SO](https://gcsradheat.com/water-heaters/rheem/cproph50-t2-rh375-so/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (+0.03) | 846 |
| [Friedrich PROH50 T2 FD400-SO](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd400-so/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (+0.03) | 846 |

## When Should Homeowners Skip Noritz NHP-50-240 (Hybrid/Electric Heat Pump)?

Check Noritz NHP-50-240's mechanical constraints—including utility space, Electric capacity, and Pass: +1.55 / +67.4% status—against typical residential installations.

### Key Limitations & Exclusions

- Noritz NHP-50-240 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 48 dBA; avoid mounting Noritz NHP-50-240 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Noritz NHP-50-240** Strong Fit — 3.85 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Ariston ARIHPWH-50-T footprint.

## Sizing, Efficiency & Recall Answers for Noritz NHP-50-240

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will Noritz NHP-50-240 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.85 UEF, Noritz NHP-50-240 shows Pass: +1.55 / +67.4% relative to May 6, 2029 federal DOE limits while placing #217 of 706 (top 31.2%) among 706 Hybrid/Electric Heat Pump peers like Ariston ARIHPWH-50-T.

### Will Noritz NHP-50-240 fit through a standard utility door and 72-inch basement ceiling?

Measuring 61.4 in. tall by 22 in. diameter, Noritz NHP-50-240 notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support Noritz NHP-50-240 during replacement?

Electrical specs for Noritz NHP-50-240 call for 240V at 21.3A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for Noritz NHP-50-240?

At 18.16 cents/kWh national residential pricing, Noritz NHP-50-240's 844 kWh/yr draw equals roughly $153 annually or $1,530 across a 10-year horizon (ranging from $123/yr in Washington hydro tiers up to $398/yr in Hawaii).

### When is Noritz NHP-50-240 a poor fit for a residential replacement?

Avoid placing Noritz NHP-50-240 directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 48 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does Noritz NHP-50-240 deliver?

With 68 gal FHR (-4 gal vs. 72 gal median), Noritz NHP-50-240 fits larger 3–5 person homes cleanly.

### How do you verify manufacturing age and recall status on Noritz NHP-50-240?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Noritz; verify exact manufacturing week for Noritz NHP-50-240 using the Serial Number Lookup tool.

### Does Noritz NHP-50-240 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Noritz NHP-50-240. Closest peer in Hybrid/Electric Heat Pump is Ariston ARIHPWH-50-T (3.83 UEF).

## Related Rebate, Gas-Line & Serial Tools for NHP-50-240

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Ariston ARIHPWH-50-T (3.83 UEF)→](https://gcsradheat.com/water-heaters/ariston/arihpwh-50-t/)
- [Compare Lennox WHHP050T45MD240S (3.83 UEF)→](https://gcsradheat.com/water-heaters/lennox/whhp050t45md240s/)
- [View All Noritz Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/noritz/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)