title: "Noritz NHP80 (3.48 UEF, 74 gal) — TapAndPipe"
url: https://gcsradheat.com/water-heaters/noritz/nhp80/
description: "The Noritz NHP80 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.48 UEF rating across its 74-gallon nominal tank, 86 gal First Hour Rating."
---

ENERGY STAR water heater model · PD 3798600

# Noritz NHP80 Water Heater Specifications (3.48 UEF)

The Noritz NHP80 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.48 UEF rating across its 74-gallon nominal tank, 86 gal First Hour Rating, ranking #545 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3798600). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.98 / +39.2%. Rated annual electricity draw of 1,424 kWh/yr equates to roughly $259/yr ($2,586 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Hubbell ME80HPT (3.48 UEF).

- **Uniform Energy Factor**: 3.48 UEF

- **Cohort UEF Rank**: #545 of 706

- **First Hour Rating**: 86 gal

- **Storage Volume**: 74 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.98 / +39.2%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Noritz NHP80 relative to the cohort median.

Efficiency comparison & rule summary

Noritz NHP80 (3.48 UEF) ranks #545 of 706 Hybrid/Electric Heat Pump models — 4-way tie; more efficient than 22.4% of Hybrid/Electric Heat Pump models, -0.22 UEF below the 3.70 UEF median.

Federal 2029 margin for Noritz NHP80: +0.98 UEF (+39.2%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,424 kWh/yr for Noritz NHP80 runs ~$259/yr vs. ~$978/yr for a 0.92 UEF electric tank.

State electric sensitivity for Noritz NHP80: 10-year operating spend spans $2,083 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,718 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Noritz NHP80 (3.48 UEF) compares closely with Hubbell ME80HPT (3.48 UEF, at parity) and VAUGHN THERMAL ME80HPT (3.48 UEF, at parity).

## What Physical and Thermal Ratings Define Noritz NHP80?

Positioning at #545 of 706 out of 706 Hybrid/Electric Heat Pump peers, Noritz NHP80 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Noritz](https://gcsradheat.com/brands/noritz/) | 23 certified listings | ENERGY STAR PD 3798600 |
| Model Number | NHP80 | Draw pattern: High-Usage | NHP80 |
| Uniform Energy Factor (UEF) | 3.48 | -0.22 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 86 gal | +14 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,424 kWh/yr | +352 kWh/yr vs. 1,072 kWh/yr median | Est. $259/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 365% | -64.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74" H x 28" D | Needs >72 in. overhead clearance; tight at 28 in. door (28" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 23 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 54 dBA | +5 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2024-11-12 | Certified 2024-11-12 | Markets: United States, Canada |

## Why Do State Utility Rates Shift NHP80 Running Costs?

Consuming 1,424 kWh annually puts Noritz NHP80 near $259/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $259/yr | $2,586 | $7,195 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $672/yr | $6,718 | $18,693 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $424/yr | $4,236 | $11,787 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $227/yr | $2,266 | $6,304 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $208/yr | $2,083 | $5,796 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,424 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any Noritz Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Noritz; confirm tank age separately using the rating-plate serial pattern. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## What Are 5 Direct Alternatives to Noritz NHP80?

Homeowners cross-shopping Noritz NHP80 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Hubbell ME80HPT](https://gcsradheat.com/water-heaters/hubbell/me80hpt/) | Hybrid/Electric Heat Pump | 74 gal | 86 gal | 3.48 (at parity) | 1,424 |
| [VAUGHN THERMAL ME80HPT](https://gcsradheat.com/water-heaters/vaughn-thermal/me80hpt/) | Hybrid/Electric Heat Pump | 74 gal | 86 gal | 3.48 (at parity) | 1,424 |
| [1HVAC ACIQ-80G-HP-WH](https://gcsradheat.com/water-heaters/1hvac/aciq-80g-hp-wh/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (+0.52) | 1,240 |
| [ACIQ ACIQ-80G-HP-WH](https://gcsradheat.com/water-heaters/aciq/aciq-80g-hp-wh/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (+0.52) | 1,240 |
| [VAUGHN THERMAL ME80HPT-CN](https://gcsradheat.com/water-heaters/vaughn-thermal/me80hpt-cn/) | Hybrid/Electric Heat Pump | 74 gal | 86 gal | 3.48 (at parity) | 1,424 |

## Which Home Setups Are NOT a Fit for Noritz NHP80?

Comparing Noritz NHP80 against Hubbell ME80HPT requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- Noritz NHP80 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 54 dBA; avoid mounting Noritz NHP80 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Noritz NHP80** Strong Fit — 3.48 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Hubbell ME80HPT footprint.

## Sizing, Efficiency & Recall Answers for Noritz NHP80

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Noritz NHP80 score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Noritz NHP80 logs 3.48 UEF (Pass: +0.98 / +39.2%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing Noritz NHP80?

With a 74 in. height and 28 in. diameter, Noritz NHP80 fits spaces matching: needs >72 in. overhead clearance; tight at 28 in. door (28" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits Noritz NHP80?

Powered via 240V at 23A max, Noritz NHP80 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for Noritz NHP80?

Annual electric spend for Noritz NHP80 (1,424 kWh/yr) averages $259/yr nationwide (ranging from $208/yr in Washington hydro tiers up to $672/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing Noritz NHP80?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Noritz NHP80.

### Is Noritz NHP80 sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Noritz NHP80 at 86 gal First Hour Rating (+14 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does Noritz have active CPSC SaferProducts notices affecting NHP80?

Zero CPSC recall alerts matched Noritz (2026-11-23 check). Keep your Noritz NHP80 serial code handy to track standard 6-to-12-year OEM warranty coverage.

### Which competing water heater matches Noritz NHP80 (3.48 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Noritz NHP80. Closest peer in Hybrid/Electric Heat Pump is Hubbell ME80HPT (3.48 UEF).

## Related Rebate, Gas-Line & Serial Tools for NHP80

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Hubbell ME80HPT (3.48 UEF)→](https://gcsradheat.com/water-heaters/hubbell/me80hpt/)
- [Compare VAUGHN THERMAL ME80HPT (3.48 UEF)→](https://gcsradheat.com/water-heaters/vaughn-thermal/me80hpt/)
- [View All Noritz Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/noritz/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)