title: "Noritz NRCR92DV (GQ-C2660WXQ-FF US) (0.95 UEF, Gas Tankless)"
url: https://gcsradheat.com/water-heaters/noritz/nrcr92dv-gq-c2660wxq-ff-us/
description: "Engineered as a Natural Gas, Propane Gas Tankless unit, Noritz NRCR92DV (GQ-C2660WXQ-FF US) achieves a certified 0.95 UEF rating and ranks #159 of 464 in its."
---

ENERGY STAR water heater model · PD 2408717

# Noritz NRCR92DV (GQ-C2660WXQ-FF US) Water Heater Specifications (0.95 UEF)

Engineered as a Natural Gas, Propane Gas Tankless unit, Noritz NRCR92DV (GQ-C2660WXQ-FF US) achieves a certified 0.95 UEF rating and ranks #159 of 464 in its 464-model cohort (PD 2408717), recording Pass: +0.04 / +4.4% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

- **Uniform Energy Factor**: 0.95 UEF

- **Cohort UEF Rank**: #159 of 464

- **First Hour Rating**: On-Demand

- **Storage Volume**: Tankless

- **Fuel / Type**: Natural Gas, Propane / Gas Tankless

- **DOE 2029 Rule Status**: Pass: +0.04 / +4.4%

Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils

Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Noritz NRCR92DV (GQ-C2660WXQ-FF US) relative to the cohort median.

Efficiency comparison & rule summary

Within the 464-unit Gas Tankless cohort, Noritz NRCR92DV (GQ-C2660WXQ-FF US) logs 0.95 UEF and ranks #159 of 464.

Noritz NRCR92DV (GQ-C2660WXQ-FF US) delivers +0.04 UEF (+4.4%) margin above the 0.91 UEF Natural Gas, Propane tankless mandate.

Cross-shopping Noritz NRCR92DV (GQ-C2660WXQ-FF US) (0.95 UEF)? Check A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) and American GT-240-NEH 1** (0.95 UEF, at parity).

## Where Does Noritz NRCR92DV (GQ-C2660WXQ-FF US) Rank Against Peer Gas Tankless Units?

Audited against 464 ENERGY STAR Gas Tankless listings, Noritz NRCR92DV (GQ-C2660WXQ-FF US) holds #159 of 464; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Noritz](https://gcsradheat.com/brands/noritz/) | 23 certified listings | ENERGY STAR PD 2408717 |
| Model Number | NRCR92DV (GQ-C2660WXQ-FF US) | Draw pattern: High-Usage | NRCR92DV (GQ-C2660WXQ-FF US) |
| Uniform Energy Factor (UEF) | 0.95 | At 0.95 UEF median | 10 CFR 430 Test Method |
| Electrical Circuit Requirements | 0.5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on Noritz Units?

No open CPSC recall alerts appeared for Noritz as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Competing Gas Tankless Models Compare Closest to NRCR92DV (GQ-C2660WXQ-FF US)?

Compare five nearby ENERGY STAR Gas Tankless options matched closely to Noritz NRCR92DV (GQ-C2660WXQ-FF US)'s gallon capacity and 0.95 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith ACT-199O-N 1**](https://gcsradheat.com/water-heaters/a-o-smith/act-199o-n-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [American GT-240-NEH 1**](https://gcsradheat.com/water-heaters/american/gt-240-neh-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [Bosch T9800 SE 160](https://gcsradheat.com/water-heaters/bosch/t9800-se-160/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [Bradford White RTG-K-160N1](https://gcsradheat.com/water-heaters/bradford-white/rtg-k-160n1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [A. O. Smith ACT-199O-P 1*1](https://gcsradheat.com/water-heaters/a-o-smith/act-199o-p-1-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |

## What Installation Caveats Apply Before Buying Noritz NRCR92DV (GQ-C2660WXQ-FF US)?

Even high-UEF units like Noritz NRCR92DV (GQ-C2660WXQ-FF US) (0.95 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Converting a 40K tank to Noritz NRCR92DV (GQ-C2660WXQ-FF US) often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
- Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Noritz NRCR92DV (GQ-C2660WXQ-FF US)'s heat exchanger.
- Condensing Noritz NRCR92DV (GQ-C2660WXQ-FF US) requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

### Which Option Fits Your Situation?

**Existing 3/4 in.+ Gas Line + Marathon Hot Draws** Strong Fit — Noritz NRCR92DV (GQ-C2660WXQ-FF US) delivers continuous 0.95 UEF performance.

**Softened/Low-Scale Water (<7.0 GPG)** Strong Fit — Minimal calcium scale between 12-month flushes.

**Long 1/2 in. Gas Run (>10 ft)** Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

## Common Homeowner Questions for Noritz NRCR92DV (GQ-C2660WXQ-FF US)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Noritz NRCR92DV (GQ-C2660WXQ-FF US) eligible for continued manufacture past May 6, 2029?

At 0.95 UEF, Noritz NRCR92DV (GQ-C2660WXQ-FF US) achieves Pass: +0.04 / +4.4% for the 2029 DOE standard and stands #159 of 464 against A. O. Smith ACT-199O-N 1** and American GT-240-NEH 1**.

### How tall and wide is Noritz NRCR92DV (GQ-C2660WXQ-FF US), and what service clearance is needed?

Noritz NRCR92DV (GQ-C2660WXQ-FF US) saves floor space via its gas tankless layout (wall-hung / compact envelope); inspect service-valve swing clearance below the bottom manifold.

### Will Noritz NRCR92DV (GQ-C2660WXQ-FF US) require upgrading household electrical panels or gas piping?

Check Natural Gas, Propane piping and venting for Noritz NRCR92DV (GQ-C2660WXQ-FF US) (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.

### Is Noritz NRCR92DV (GQ-C2660WXQ-FF US) economical to operate at 18.16 cents/kWh US electric rates?

Fuel bills for Noritz NRCR92DV (GQ-C2660WXQ-FF US) (Natural Gas, Propane, 0.95 UEF) hinge on household gallon demand and local gas utility tariffs compared with A. O. Smith ACT-199O-N 1**.

### Which installation bottlenecks limit Noritz NRCR92DV (GQ-C2660WXQ-FF US)?

Without 3/4 in.–1 in. IFGC gas sizing and Category IV PVC exhaust routing, Noritz NRCR92DV (GQ-C2660WXQ-FF US) requires added mechanical rework over standard tank replacements.

### How does Noritz NRCR92DV (GQ-C2660WXQ-FF US) handle simultaneous showers and laundry?

Noritz NRCR92DV (GQ-C2660WXQ-FF US) supplies endless hot water within its maximum BTU/flow curve—check cold-climate winter groundwater temperatures before running 3+ fixtures at once.

### How long is the warranty on Noritz NRCR92DV (GQ-C2660WXQ-FF US) and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Noritz as of 2026-11-23. Confirm install proof and serial manufacture year on Noritz NRCR92DV (GQ-C2660WXQ-FF US) before calling service.

### How do 2026 post-OBBBA rebates affect buying Noritz NRCR92DV (GQ-C2660WXQ-FF US)?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

## Next Engineering Checks for Noritz Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith ACT-199O-N 1** (0.95 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/act-199o-n-1/)
- [Compare American GT-240-NEH 1** (0.95 UEF)→](https://gcsradheat.com/water-heaters/american/gt-240-neh-1/)
- [View All Noritz Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/noritz/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)