title: "PHNIX KA06-50 (3.88 UEF, 44.5 gal)"
url: https://gcsradheat.com/water-heaters/phnix/ka06-50/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, PHNIX KA06-50 achieves a certified 3.88 UEF rating across its 44.5-gallon nominal tank, 65 gal First."
---

ENERGY STAR water heater model · PD 3619552

# PHNIX KA06-50 Water Heater Specifications (3.88 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, PHNIX KA06-50 achieves a certified 3.88 UEF rating across its 44.5-gallon nominal tank, 65 gal First Hour Rating and ranks #165 of 706 in its 706-model cohort (PD 3619552), recording Pass: +1.58 / +68.7% under 2029 DOE rules. Rated annual electricity draw of 837 kWh/yr equates to roughly $152/yr ($1,520 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Arctic Arctic-HP-Hot Water-KA06-50 (3.88 UEF).

- **Uniform Energy Factor**: 3.88 UEF

- **Cohort UEF Rank**: #165 of 706 (top 30.6%)

- **First Hour Rating**: 65 gal

- **Storage Volume**: 44.5 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.58 / +68.7%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows PHNIX KA06-50 relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, PHNIX KA06-50 logs 3.88 UEF and ranks #165 of 706.

Against 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF), PHNIX KA06-50 holds a +1.58 UEF (+68.7%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 837 kWh/yr for PHNIX KA06-50 runs ~$152/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for PHNIX KA06-50: 10-year operating spend spans $1,225 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,949 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping PHNIX KA06-50 (3.88 UEF)? Check Arctic Arctic-HP-Hot Water-KA06-50 (3.88 UEF, at parity) and Friedrich PROH50 T2 FD400-30 (3.88 UEF, at parity).

## Which Specs Set PHNIX KA06-50 Apart From Cohort Averages?

Ranked #165 of 706 (top 30.6%) inside the 706-model Hybrid/Electric Heat Pump cohort, PHNIX KA06-50 is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [PHNIX](https://gcsradheat.com/brands/phnix/) | 2 certified listings | ENERGY STAR PD 3619552 |
| Model Number | KA06-50 | Draw pattern: Medium-Usage | KA06-50 |
| Uniform Energy Factor (UEF) | 3.88 | +0.18 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 65 gal | -7 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 837 kWh/yr | -235 kWh/yr vs. 1,072 kWh/yr median | Est. $152/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 412% | -17.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 46.8" H x 22" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 27 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2024-07-02 | Certified 2024-07-02 | Markets: United States, Canada |

## How Do Regional kWh Prices Impact KA06-50 Over 10 Years?

Using EIA Table 5.6.A benchmarks, PHNIX KA06-50's 837 kWh/yr draw translates to roughly $152/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $152/yr | $1,520 | $4,890 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $395/yr | $3,949 | $12,706 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $249/yr | $2,490 | $8,012 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $133/yr | $1,332 | $4,285 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $122/yr | $1,225 | $3,940 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (837 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should PHNIX Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for PHNIX; run a quick serial-number check to verify age before replacing wear parts. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Arctic Arctic-HP-Hot Water-KA06-50](https://gcsradheat.com/water-heaters/arctic/arctic-hp-hot-water-ka06-50/) | Hybrid/Electric Heat Pump | 44.5 gal | 65 gal | 3.88 (at parity) | 837 |
| [Friedrich PROH50 T2 FD400-30](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd400-30/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| [Rheem CPROPH50 T2 RH375-SO](https://gcsradheat.com/water-heaters/rheem/cproph50-t2-rh375-so/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| [Richmond 10CE50-HP5S30](https://gcsradheat.com/water-heaters/richmond/10ce50-hp5s30/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| [Friedrich PROH50 T2 FD400-SO](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd400-so/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |

## Which Home Setups Are NOT a Fit for PHNIX KA06-50?

Comparing PHNIX KA06-50 against Arctic Arctic-HP-Hot Water-KA06-50 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- PHNIX KA06-50 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting PHNIX KA06-50 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing PHNIX KA06-50** Strong Fit — 3.88 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Arctic Arctic-HP-Hot Water-KA06-50 footprint.

## Frequently Asked Technical Questions: PHNIX KA06-50

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does PHNIX KA06-50 score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; PHNIX KA06-50 logs 3.88 UEF (Pass: +1.58 / +68.7%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing PHNIX KA06-50?

With a 46.8 in. height and 22 in. diameter, PHNIX KA06-50 fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits PHNIX KA06-50?

Powered via 240V at 27A max, PHNIX KA06-50 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for PHNIX KA06-50?

Annual electric spend for PHNIX KA06-50 (837 kWh/yr) averages $152/yr nationwide (ranging from $122/yr in Washington hydro tiers up to $395/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing PHNIX KA06-50?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on PHNIX KA06-50.

### Is PHNIX KA06-50 sized adequately for a 2-to-4-person household?

ENERGY STAR certifies PHNIX KA06-50 at 65 gal First Hour Rating (-7 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does PHNIX have active CPSC SaferProducts notices affecting KA06-50?

Zero CPSC recall alerts matched PHNIX (2026-11-23 check). Keep your PHNIX KA06-50 serial code handy to track standard 6-to-12-year OEM warranty coverage.

### Which competing water heater matches PHNIX KA06-50 (3.88 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for PHNIX KA06-50. Closest peer in Hybrid/Electric Heat Pump is Arctic Arctic-HP-Hot Water-KA06-50 (3.88 UEF).

## Essential Pre-Install Guides for PHNIX KA06-50

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Arctic Arctic-HP-Hot Water-KA06-50 (3.88 UEF)→](https://gcsradheat.com/water-heaters/arctic/arctic-hp-hot-water-ka06-50/)
- [Compare Friedrich PROH50 T2 FD400-30 (3.88 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd400-30/)
- [View All PHNIX Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/phnix/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)