title: "PHNIX KA06-80 (4.14 UEF, 71 gal) — TapAndPipe"
url: https://gcsradheat.com/water-heaters/phnix/ka06-80/
description: "With PD 3619553 certification, PHNIX KA06-80 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.14 UEF rating across its 71-gallon nominal tank, 81."
---

ENERGY STAR water heater model · PD 3619553

# PHNIX KA06-80 Water Heater Specifications (4.14 UEF)

With PD 3619553 certification, PHNIX KA06-80 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.14 UEF rating across its 71-gallon nominal tank, 81 gal First Hour Rating, standing #17 of 706 across 706 peers with Pass: +1.64 / +65.6% for May 6, 2029. Rated annual electricity draw of 1,199.7 kWh/yr equates to roughly $218/yr ($2,179 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Arctic Arctic-HP-Hot Water-KA06-80 (4.14 UEF).

- **Uniform Energy Factor**: 4.14 UEF

- **Cohort UEF Rank**: #17 of 706 (top 2.5%)

- **First Hour Rating**: 81 gal

- **Storage Volume**: 71 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.64 / +65.6%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows PHNIX KA06-80 relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places PHNIX KA06-80 at 4.14 UEF (#17 of 706; +0.44 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: PHNIX KA06-80 stands +1.64 UEF (+65.6%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,199.7 kWh/yr for PHNIX KA06-80 runs ~$218/yr vs. ~$980/yr for a 0.92 UEF electric tank.

State electric sensitivity for PHNIX KA06-80: 10-year operating spend spans $1,755 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,660 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Arctic Arctic-HP-Hot Water-KA06-80 (4.14 UEF, at parity) and Noritz NHP-80-240 (4.24 UEF, delta +0.10) bracket PHNIX KA06-80.

## How Complete Are the Certified Metrics for PHNIX KA06-80?

Standing at #17 of 706 (top 2.5%) among 706 certified Hybrid/Electric Heat Pump heaters, PHNIX KA06-80 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [PHNIX](https://gcsradheat.com/brands/phnix/) | 2 certified listings | ENERGY STAR PD 3619553 |
| Model Number | KA06-80 | Draw pattern: High-Usage | KA06-80 |
| Uniform Energy Factor (UEF) | 4.14 | +0.44 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 81 gal | +9 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,199.7 kWh/yr | +128 kWh/yr vs. 1,072 kWh/yr median | Est. $218/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 458% | +29.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 57.5" H x 25.1" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (25.1" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 27 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2024-07-02 | Certified 2024-07-02 | Markets: United States, Canada |

## What Is the Projected Utility Bill for KA06-80 by State?

At 1,199 kWh/yr, PHNIX KA06-80 averages about $218/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $218/yr | $2,179 | $7,626 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $566/yr | $5,660 | $19,812 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $357/yr | $3,569 | $12,493 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $191/yr | $1,909 | $6,681 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $176/yr | $1,755 | $6,144 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,199.7 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are PHNIX Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched PHNIX in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which 5 Models Offer Similar Output to KA06-80?

Ordered by minimal capacity and UEF spread relative to PHNIX KA06-80, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Arctic Arctic-HP-Hot Water-KA06-80](https://gcsradheat.com/water-heaters/arctic/arctic-hp-hot-water-ka06-80/) | Hybrid/Electric Heat Pump | 71 gal | 81 gal | 4.14 (at parity) | 1,199.7 |
| [Noritz NHP-80-240](https://gcsradheat.com/water-heaters/noritz/nhp-80-240/) | Hybrid/Electric Heat Pump | 71 gal | 82 gal | 4.24 (+0.10) | 1,148 |
| [LG APHWC802D](https://gcsradheat.com/water-heaters/lg/aphwc802d/) | Hybrid/Electric Heat Pump | 72 gal | 91 gal | 4.1 (-0.04) | 1,210 |
| [Friedrich PROH80 T2 FD400-30](https://gcsradheat.com/water-heaters/friedrich/proh80-t2-fd400-30/) | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (-0.07) | 1,213 |
| [LG APHWC802L](https://gcsradheat.com/water-heaters/lg/aphwc802l/) | Hybrid/Electric Heat Pump | 72 gal | 91 gal | 4.1 (-0.04) | 1,210 |

## What Installation Caveats Apply Before Buying PHNIX KA06-80?

Even high-UEF units like PHNIX KA06-80 (4.14 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- PHNIX KA06-80 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting PHNIX KA06-80 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing PHNIX KA06-80** Strong Fit — 4.14 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Arctic Arctic-HP-Hot Water-KA06-80 footprint.

## Practical Specs & Code Questions for PHNIX KA06-80

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is PHNIX KA06-80 eligible for continued manufacture past May 6, 2029?

At 4.14 UEF, PHNIX KA06-80 achieves Pass: +1.64 / +65.6% for the 2029 DOE standard and stands #17 of 706 (top 2.5%) against Arctic Arctic-HP-Hot Water-KA06-80 and Noritz NHP-80-240.

### How tall and wide is PHNIX KA06-80, and what service clearance is needed?

Physical dimensions for PHNIX KA06-80 are 57.5 in. height and 25.1 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (25.1" d)); verify stair turns and drain pan width before delivery.

### Will PHNIX KA06-80 require upgrading household electrical panels or gas piping?

PHNIX KA06-80 draws 240V at 27A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is PHNIX KA06-80 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $218/yr ($2,180 over 10 years) to power PHNIX KA06-80 at 1,199.7 kWh/yr under the 18.16 cents/kWh US average (ranging from $176/yr in Washington hydro tiers up to $566/yr in Hawaii).

### Which installation bottlenecks limit PHNIX KA06-80?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, PHNIX KA06-80 drops into resistance mode more often.

### How does PHNIX KA06-80 handle simultaneous showers and laundry?

Delivering 81 gal in the first hour (+9 gal vs. 72 gal median), PHNIX KA06-80 combines 71 gal tank storage with rapid burner/element recovery.

### How long is the warranty on PHNIX KA06-80 and how do you decode its serial?

CPSC records show 0 active plumbing recalls for PHNIX as of 2026-11-23. Confirm install proof and serial manufacture year on PHNIX KA06-80 before calling service.

### How do 2026 post-OBBBA rebates affect buying PHNIX KA06-80?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Arctic Arctic-HP-Hot Water-KA06-80 (4.14 UEF).

## Installation, Serial & DOE 2029 Links for KA06-80

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Arctic Arctic-HP-Hot Water-KA06-80 (4.14 UEF)→](https://gcsradheat.com/water-heaters/arctic/arctic-hp-hot-water-ka06-80/)
- [Compare Noritz NHP-80-240 (4.24 UEF)→](https://gcsradheat.com/water-heaters/noritz/nhp-80-240/)
- [View All PHNIX Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/phnix/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)