title: "PolarWave ACIQ-80G-HP-WH (4 UEF, 74 gal)"
url: https://gcsradheat.com/water-heaters/polarwave/aciq-80g-hp-wh/
description: "Certified at 4.0 UEF across its 74-gallon nominal tank, 91 gal First Hour Rating, PolarWave ACIQ-80G-HP-WH (Hybrid/Electric Heat Pump, Electric) places #106 of."
---

ENERGY STAR water heater model · PD 3626851

# PolarWave ACIQ-80G-HP-WH Water Heater Specifications (4 UEF)

Certified at 4.0 UEF across its 74-gallon nominal tank, 91 gal First Hour Rating, PolarWave ACIQ-80G-HP-WH (Hybrid/Electric Heat Pump, Electric) places #106 of 706 out of 706 ENERGY STAR models (PD 3626851). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.50 / +60.0%. Rated annual electricity draw of 1,240 kWh/yr equates to roughly $225/yr ($2,252 over 10 years) at 18.16 cents/kWh. Closest certified alternative is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).

- **Uniform Energy Factor**: 4.0 UEF

- **Cohort UEF Rank**: #106 of 706 (top 19.8%)

- **First Hour Rating**: 91 gal

- **Storage Volume**: 74 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.50 / +60.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows PolarWave ACIQ-80G-HP-WH relative to the cohort median.

Efficiency comparison & rule summary

Tested at 4.0 UEF, PolarWave ACIQ-80G-HP-WH places #106 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.30 UEF vs. 3.70 UEF median).

PolarWave ACIQ-80G-HP-WH clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.50 UEF (+60.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,240 kWh/yr for PolarWave ACIQ-80G-HP-WH runs ~$225/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 49 dBA (quieter than 12.8% of Hybrid/Electric Heat Pump models).

State electric sensitivity for PolarWave ACIQ-80G-HP-WH: 10-year operating spend spans $1,814 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,850 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to PolarWave ACIQ-80G-HP-WH include 1HVAC ACIQ-80G-HP-WH (4.0 UEF, at parity) alongside ACIQ ACIQ-80G-HP-WH (4.0 UEF, at parity).

## Where Does PolarWave ACIQ-80G-HP-WH Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, PolarWave ACIQ-80G-HP-WH holds #106 of 706 (top 19.8%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [PolarWave](https://gcsradheat.com/brands/polarwave/) | 2 certified listings | ENERGY STAR PD 3626851 |
| Model Number | ACIQ-80G-HP-WH | Draw pattern: High-Usage | ACIQ-80G-HP-WH |
| Uniform Energy Factor (UEF) | 4.0 | +0.30 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 91 gal | +19 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,240 kWh/yr | +168 kWh/yr vs. 1,072 kWh/yr median | Est. $225/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 450% | +21.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 41.7" H x 21.8" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 24 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Sound Pressure Level | 49 dBA | quieter than 12.8% of Hybrid/Electric Heat Pump models · At 49 dBA median | Indoor placement check |
| Certification Date | 2024-11-11 | Certified 2024-11-11 | Markets: United States, Canada |

## How Much Electricity Does ACIQ-80G-HP-WH Use in Different States?

Estimated at $225/yr nationally (1,240 kWh/yr), 10-year utility spending for PolarWave ACIQ-80G-HP-WH shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $225/yr | $2,252 | $7,538 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $585/yr | $5,850 | $19,584 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $369/yr | $3,689 | $12,349 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $197/yr | $1,973 | $6,604 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $181/yr | $1,814 | $6,073 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,240 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on PolarWave Units?

No open CPSC recall alerts appeared for PolarWave as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to ACIQ-80G-HP-WH?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to PolarWave ACIQ-80G-HP-WH's gallon capacity and 4.0 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [1HVAC ACIQ-80G-HP-WH](https://gcsradheat.com/water-heaters/1hvac/aciq-80g-hp-wh/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| [ACIQ ACIQ-80G-HP-WH](https://gcsradheat.com/water-heaters/aciq/aciq-80g-hp-wh/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| [Bosch TR7000T - 80CA](https://gcsradheat.com/water-heaters/bosch/tr7000t-80ca/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| [Custom Comfort CCOHPWH80A](https://gcsradheat.com/water-heaters/custom-comfort/ccohpwh80a/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |
| [Bosch TR7000T - 80US](https://gcsradheat.com/water-heaters/bosch/tr7000t-80us/) | Hybrid/Electric Heat Pump | 74 gal | 91 gal | 4.0 (at parity) | 1,240 |

## When Should Homeowners Skip PolarWave ACIQ-80G-HP-WH (Hybrid/Electric Heat Pump)?

Check PolarWave ACIQ-80G-HP-WH's mechanical constraints—including utility space, Electric capacity, and Pass: +1.50 / +60.0% status—against typical residential installations.

### Key Limitations & Exclusions

- PolarWave ACIQ-80G-HP-WH needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting PolarWave ACIQ-80G-HP-WH directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing PolarWave ACIQ-80G-HP-WH** Strong Fit — 4.0 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare 1HVAC ACIQ-80G-HP-WH footprint.

## Common Homeowner Questions for PolarWave ACIQ-80G-HP-WH

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will PolarWave ACIQ-80G-HP-WH stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 4.0 UEF, PolarWave ACIQ-80G-HP-WH shows Pass: +1.50 / +60.0% relative to May 6, 2029 federal DOE limits while placing #106 of 706 (top 19.8%) among 706 Hybrid/Electric Heat Pump peers like 1HVAC ACIQ-80G-HP-WH.

### Will PolarWave ACIQ-80G-HP-WH fit through a standard utility door and 72-inch basement ceiling?

Measuring 41.7 in. tall by 21.8 in. diameter, PolarWave ACIQ-80G-HP-WH notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.8" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support PolarWave ACIQ-80G-HP-WH during replacement?

Electrical specs for PolarWave ACIQ-80G-HP-WH call for 240V at 24A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for PolarWave ACIQ-80G-HP-WH?

At 18.16 cents/kWh national residential pricing, PolarWave ACIQ-80G-HP-WH's 1,240 kWh/yr draw equals roughly $225 annually or $2,250 across a 10-year horizon (ranging from $181/yr in Washington hydro tiers up to $585/yr in Hawaii).

### When is PolarWave ACIQ-80G-HP-WH a poor fit for a residential replacement?

Avoid placing PolarWave ACIQ-80G-HP-WH directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does PolarWave ACIQ-80G-HP-WH deliver?

With 91 gal FHR (+19 gal vs. 72 gal median), PolarWave ACIQ-80G-HP-WH fits larger 3–5 person homes cleanly.

### How do you verify manufacturing age and recall status on PolarWave ACIQ-80G-HP-WH?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for PolarWave; verify exact manufacturing week for PolarWave ACIQ-80G-HP-WH using the Serial Number Lookup tool.

### Does PolarWave ACIQ-80G-HP-WH qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for PolarWave ACIQ-80G-HP-WH. Closest peer in Hybrid/Electric Heat Pump is 1HVAC ACIQ-80G-HP-WH (4.0 UEF).

## Next Engineering Checks for PolarWave Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare 1HVAC ACIQ-80G-HP-WH (4.0 UEF)→](https://gcsradheat.com/water-heaters/1hvac/aciq-80g-hp-wh/)
- [Compare ACIQ ACIQ-80G-HP-WH (4.0 UEF)→](https://gcsradheat.com/water-heaters/aciq/aciq-80g-hp-wh/)
- [View All PolarWave Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/polarwave/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)