title: "Radiant SFK 55 (0.95 UEF, Gas Tankless)"
url: https://gcsradheat.com/water-heaters/radiant/sfk-55/
description: "Engineered as a Natural Gas Gas Tankless unit, Radiant SFK 55 achieves a certified 0.95 UEF rating and ranks #159 of 464 in its 464-model cohort (PD 4016237)."
---

ENERGY STAR water heater model · PD 4016237

# Radiant SFK 55 Water Heater Specifications (0.95 UEF)

Engineered as a Natural Gas Gas Tankless unit, Radiant SFK 55 achieves a certified 0.95 UEF rating and ranks #159 of 464 in its 464-model cohort (PD 4016237), recording Pass: +0.04 / +4.4% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

- **Uniform Energy Factor**: 0.95 UEF

- **Cohort UEF Rank**: #159 of 464

- **First Hour Rating**: On-Demand

- **Storage Volume**: Tankless

- **Fuel / Type**: Natural Gas / Gas Tankless

- **DOE 2029 Rule Status**: Pass: +0.04 / +4.4%

Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils

Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Radiant SFK 55 relative to the cohort median.

Efficiency comparison & rule summary

Within the 464-unit Gas Tankless cohort, Radiant SFK 55 logs 0.95 UEF and ranks #159 of 464.

Radiant SFK 55 delivers +0.04 UEF (+4.4%) margin above the 0.91 UEF Natural Gas tankless mandate; thermal recovery tests at 98% (At 98.0% median).

Cross-shopping Radiant SFK 55 (0.95 UEF)? Check A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) and American GT-240-NEH 1** (0.95 UEF, at parity).

## What Physical and Thermal Ratings Define Radiant SFK 55?

Positioning at #159 of 464 out of 464 Gas Tankless peers, Radiant SFK 55 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Radiant](https://gcsradheat.com/brands/radiant/) | 2 certified listings | ENERGY STAR PD 4016237 |
| Model Number | SFK 55 | Draw pattern: High-Usage | SFK 55 |
| Uniform Energy Factor (UEF) | 0.95 | At 0.95 UEF median | 10 CFR 430 Test Method |
| Thermal Recovery Efficiency | 98% | At 98.0% median | ENERGY STAR Dataset |
| Electrical Circuit Requirements | 1.8 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2025-04-23 | Certified 2025-04-23 | Markets: Canada |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any Radiant Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Radiant; confirm tank age separately using the rating-plate serial pattern. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

## What Are 5 Direct Alternatives to Radiant SFK 55?

Homeowners cross-shopping Radiant SFK 55 frequently review these five Gas Tankless models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith ACT-199O-N 1**](https://gcsradheat.com/water-heaters/a-o-smith/act-199o-n-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [American GT-240-NEH 1**](https://gcsradheat.com/water-heaters/american/gt-240-neh-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [Bosch T9800 SE 160](https://gcsradheat.com/water-heaters/bosch/t9800-se-160/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [Bradford White RTG-K-160N1](https://gcsradheat.com/water-heaters/bradford-white/rtg-k-160n1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [A. O. Smith ACT-199O-P 1*1](https://gcsradheat.com/water-heaters/a-o-smith/act-199o-p-1-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |

## When Should Homeowners Skip Radiant SFK 55 (Gas Tankless)?

Check Radiant SFK 55's mechanical constraints—including utility space, Natural Gas capacity, and Pass: +0.04 / +4.4% status—against typical residential installations.

### Key Limitations & Exclusions

- Converting a 40K tank to Radiant SFK 55 often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
- Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Radiant SFK 55's heat exchanger.
- Condensing Radiant SFK 55 requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

### Which Option Fits Your Situation?

**Existing 3/4 in.+ Gas Line + Marathon Hot Draws** Strong Fit — Radiant SFK 55 delivers continuous 0.95 UEF performance.

**Softened/Low-Scale Water (<7.0 GPG)** Strong Fit — Minimal calcium scale between 12-month flushes.

**Long 1/2 in. Gas Run (>10 ft)** Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

## Sizing, Efficiency & Recall Answers for Radiant SFK 55

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will Radiant SFK 55 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 0.95 UEF, Radiant SFK 55 shows Pass: +0.04 / +4.4% relative to May 6, 2029 federal DOE limits while placing #159 of 464 among 464 Gas Tankless peers like A. O. Smith ACT-199O-N 1**.

### Will Radiant SFK 55 fit through a standard utility door and 72-inch basement ceiling?

Using a wall-mounted gas tankless chassis, Radiant SFK 55 eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.

### Do existing utility hookups support Radiant SFK 55 during replacement?

Fueled by Natural Gas, Radiant SFK 55 specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.

### What is the estimated 10-year operating spend for Radiant SFK 55?

Because Radiant SFK 55 burns Natural Gas at 0.95 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 464 peers.

### When is Radiant SFK 55 a poor fit for a residential replacement?

Skip Radiant SFK 55 as a quick swap when long 1/2 in. iron gas lines starve ignition (triggering E003/11 codes) or when Type B metal chimney vents cannot handle condensing PVC.

### What First Hour Rating or flow capacity does Radiant SFK 55 deliver?

As an on-demand Gas Tankless model, Radiant SFK 55 has no tank depletion limit—verify GPM output at your state's 40–65 °F winter water rise.

### How do you verify manufacturing age and recall status on Radiant SFK 55?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Radiant; verify exact manufacturing week for Radiant SFK 55 using the Serial Number Lookup tool.

### Does Radiant SFK 55 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Radiant SFK 55. Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

## Related Rebate, Gas-Line & Serial Tools for SFK 55

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith ACT-199O-N 1** (0.95 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/act-199o-n-1/)
- [Compare American GT-240-NEH 1** (0.95 UEF)→](https://gcsradheat.com/water-heaters/american/gt-240-neh-1/)
- [View All Radiant Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/radiant/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)