---
title: "RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** (3.45 UEF, 67 gal)"
url: https://gcsradheat.com/water-heaters/reliance-water-heaters/10-66-dhphtcta-1/
description: "Certified at 3.45 UEF across its 67-gallon nominal tank, 79 gal First Hour Rating, RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** (Hybrid/Electric Heat Pump."
---

ENERGY STAR water heater model · PD 2408876

# RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** Water Heater Specifications (3.45 UEF)

Certified at 3.45 UEF across its 67-gallon nominal tank, 79 gal First Hour Rating, RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** (Hybrid/Electric Heat Pump, Electric) places #563 of 706 out of 706 ENERGY STAR models (PD 2408876). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.95 / +38.0%. Rated annual electricity draw of 1,381 kWh/yr equates to roughly $251/yr ($2,508 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPTU-66CTA 1** (3.45 UEF).

- **Uniform Energy Factor**: 3.45 UEF

- **Cohort UEF Rank**: #563 of 706

- **First Hour Rating**: 79 gal

- **Storage Volume**: 67 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.95 / +38.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** relative to the cohort median.

Efficiency comparison & rule summary

Tested at 3.45 UEF, RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.25 UEF vs. 3.70 UEF median).

RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.95 UEF (+38.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,381 kWh/yr for RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** runs ~$251/yr vs. ~$941/yr for a 0.92 UEF electric tank.

State electric sensitivity for RELIANCE WATER HEATERS 10-66-DHPHTCTA 1**: 10-year operating spend spans $2,020 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,516 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** include A. O. Smith HPTU-66CTA 1** (3.45 UEF, at parity) alongside American HPHE10266H045DVCTA-1** (3.45 UEF, at parity).

## What Physical and Thermal Ratings Define RELIANCE WATER HEATERS 10-66-DHPHTCTA 1**?

Positioning at #563 of 706 out of 706 Hybrid/Electric Heat Pump peers, RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [RELIANCE WATER HEATERS](https://gcsradheat.com/brands/reliance-water-heaters/) | 71 certified listings | ENERGY STAR PD 2408876 |
| Model Number | 10-66-DHPHTCTA 1** | Draw pattern: High-Usage | 10-66-DHPHTCTA 1** |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 79 gal | +7 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,381 kWh/yr | +309 kWh/yr vs. 1,072 kWh/yr median | Est. $251/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 265% | -164.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61" H x 23" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |

## Why Do State Utility Rates Shift 10-66-DHPHTCTA 1** Running Costs?

Consuming 1,381 kWh annually puts RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** near $251/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $251/yr | $2,508 | $6,897 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $652/yr | $6,516 | $17,919 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $411/yr | $4,108 | $11,299 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $220/yr | $2,197 | $6,043 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $202/yr | $2,020 | $5,556 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,381 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any RELIANCE WATER HEATERS Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 3 brand notices under RELIANCE WATER HEATERS; inspect model coverage dates prior to valve or anode service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**3 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #04128 (2004-04-28):** CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls ([CPSC Notice](https://www.cpsc.gov/Recalls/2004/CPSC-White-Rodgers-Announce-Recall-of-LP-and-Convertible-Gas-Water-Heater-Temperature-Controls-))

## What Are 5 Direct Alternatives to RELIANCE WATER HEATERS 10-66-DHPHTCTA 1**?

Homeowners cross-shopping RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith HPTU-66CTA 1**](https://gcsradheat.com/water-heaters/a-o-smith/hptu-66cta-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
| [American HPHE10266H045DVCTA-1**](https://gcsradheat.com/water-heaters/american/hphe10266h045dvcta-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
| [Lochinvar HPA068KD 1**](https://gcsradheat.com/water-heaters/lochinvar/hpa068kd-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
| [State HPX-66-DHPTCTA 1**](https://gcsradheat.com/water-heaters/state/hpx-66-dhptcta-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
| [A. O. Smith HPTU-66DR 1**](https://gcsradheat.com/water-heaters/a-o-smith/hptu-66dr-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |

## Who Is RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** Best For — and When Should You Pick A. O. Smith HPTU-66CTA 1**?

Evaluate whether RELIANCE WATER HEATERS 10-66-DHPHTCTA 1**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing RELIANCE WATER HEATERS 10-66-DHPHTCTA 1 Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith HPTU-66CTA 1** footprint.

## Sizing, Efficiency & Recall Answers for RELIANCE WATER HEATERS 10-66-DHPHTCTA 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** (3.45 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** records 3.45 UEF (Pass: +0.95 / +38.0%), placing #563 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** fit inside a tight hallway closet or low-headroom utility room?

RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** requires room for its 61 in. vertical shell and 23 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern RELIANCE WATER HEATERS 10-66-DHPHTCTA 1**?

For RELIANCE WATER HEATERS 10-66-DHPHTCTA 1**, plan a 240V circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for RELIANCE WATER HEATERS 10-66-DHPHTCTA 1**?

Using 1,381 kWh/yr, RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** generates an estimated $251/yr electric bill at 18.16 cents/kWh (ranging from $202/yr in Washington hydro tiers up to $652/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** (3.45 UEF)?

RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith HPTU-66CTA 1**.

### What hot-water delivery rating governs RELIANCE WATER HEATERS 10-66-DHPHTCTA 1**?

Rated for 79 gal FHR (+7 gal vs. 72 gal median), RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** for recalls and tank age?

CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What alternative models sit closest to RELIANCE WATER HEATERS 10-66-DHPHTCTA 1** in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPTU-66CTA 1** (3.45 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Related Rebate, Gas-Line & Serial Tools for 10-66-DHPHTCTA 1**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith HPTU-66CTA 1** (3.45 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hptu-66cta-1/)
- [Compare American HPHE10266H045DVCTA-1** (3.45 UEF)→](https://gcsradheat.com/water-heaters/american/hphe10266h045dvcta-1/)
- [View All RELIANCE WATER HEATERS Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/reliance-water-heaters/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)
