title: "RELIANCE WATER HEATERS 10-66-DHPHTNE 1** (3.45 UEF, 67 gal)"
url: https://gcsradheat.com/water-heaters/reliance-water-heaters/10-66-dhphtne-1/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, RELIANCE WATER HEATERS 10-66-DHPHTNE 1** achieves a certified 3.45 UEF rating across its 67-gallon."
---

ENERGY STAR water heater model · PD 2408872

# RELIANCE WATER HEATERS 10-66-DHPHTNE 1** Water Heater Specifications (3.45 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, RELIANCE WATER HEATERS 10-66-DHPHTNE 1** achieves a certified 3.45 UEF rating across its 67-gallon nominal tank, 79 gal First Hour Rating and ranks #563 of 706 in its 706-model cohort (PD 2408872), recording Pass: +0.95 / +38.0% under 2029 DOE rules. Rated annual electricity draw of 1,381 kWh/yr equates to roughly $251/yr ($2,508 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPTU-66CTA 1** (3.45 UEF).

- **Uniform Energy Factor**: 3.45 UEF

- **Cohort UEF Rank**: #563 of 706

- **First Hour Rating**: 79 gal

- **Storage Volume**: 67 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.95 / +38.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows RELIANCE WATER HEATERS 10-66-DHPHTNE 1** relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, RELIANCE WATER HEATERS 10-66-DHPHTNE 1** logs 3.45 UEF and ranks #563 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), RELIANCE WATER HEATERS 10-66-DHPHTNE 1** holds a +0.95 UEF (+38.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,381 kWh/yr for RELIANCE WATER HEATERS 10-66-DHPHTNE 1** runs ~$251/yr vs. ~$941/yr for a 0.92 UEF electric tank.

State electric sensitivity for RELIANCE WATER HEATERS 10-66-DHPHTNE 1**: 10-year operating spend spans $2,020 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,516 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping RELIANCE WATER HEATERS 10-66-DHPHTNE 1** (3.45 UEF)? Check A. O. Smith HPTU-66CTA 1** (3.45 UEF, at parity) and American HPHE10266H045DVCTA-1** (3.45 UEF, at parity).

## Which Specs Set RELIANCE WATER HEATERS 10-66-DHPHTNE 1** Apart From Cohort Averages?

Ranked #563 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, RELIANCE WATER HEATERS 10-66-DHPHTNE 1** is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [RELIANCE WATER HEATERS](https://gcsradheat.com/brands/reliance-water-heaters/) | 71 certified listings | ENERGY STAR PD 2408872 |
| Model Number | 10-66-DHPHTNE 1** | Draw pattern: High-Usage | 10-66-DHPHTNE 1** |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 79 gal | +7 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,381 kWh/yr | +309 kWh/yr vs. 1,072 kWh/yr median | Est. $251/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 265% | -164.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61" H x 23" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |

## How Do Regional kWh Prices Impact 10-66-DHPHTNE 1** Over 10 Years?

Using EIA Table 5.6.A benchmarks, RELIANCE WATER HEATERS 10-66-DHPHTNE 1**'s 1,381 kWh/yr draw translates to roughly $251/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $251/yr | $2,508 | $6,897 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $652/yr | $6,516 | $17,919 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $411/yr | $4,108 | $11,299 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $220/yr | $2,197 | $6,043 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $202/yr | $2,020 | $5,556 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,381 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should RELIANCE WATER HEATERS Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 3 filings tied to RELIANCE WATER HEATERS; verify whether your 10-66-DHPHTNE 1** production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**3 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #04128 (2004-04-28):** CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls ([CPSC Notice](https://www.cpsc.gov/Recalls/2004/CPSC-White-Rodgers-Announce-Recall-of-LP-and-Convertible-Gas-Water-Heater-Temperature-Controls-))

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith HPTU-66CTA 1**](https://gcsradheat.com/water-heaters/a-o-smith/hptu-66cta-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
| [American HPHE10266H045DVCTA-1**](https://gcsradheat.com/water-heaters/american/hphe10266h045dvcta-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
| [Lochinvar HPA068KD 1**](https://gcsradheat.com/water-heaters/lochinvar/hpa068kd-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
| [State HPX-66-DHPTCTA 1**](https://gcsradheat.com/water-heaters/state/hpx-66-dhptcta-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |
| [A. O. Smith HPTU-66DR 1**](https://gcsradheat.com/water-heaters/a-o-smith/hptu-66dr-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (at parity) | 1,381 |

## What Are the Limitations of RELIANCE WATER HEATERS 10-66-DHPHTNE 1** and Who Should Not Install It?

Before ordering RELIANCE WATER HEATERS 10-66-DHPHTNE 1** (Hybrid/Electric Heat Pump, 3.45 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- RELIANCE WATER HEATERS 10-66-DHPHTNE 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting RELIANCE WATER HEATERS 10-66-DHPHTNE 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing RELIANCE WATER HEATERS 10-66-DHPHTNE 1 Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith HPTU-66CTA 1** footprint.

## Frequently Asked Technical Questions: RELIANCE WATER HEATERS 10-66-DHPHTNE 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does RELIANCE WATER HEATERS 10-66-DHPHTNE 1** pass the May 6, 2029 federal DOE efficiency rule?

RELIANCE WATER HEATERS 10-66-DHPHTNE 1** carries a verified 3.45 UEF rating (Pass: +0.95 / +38.0%), ranking #563 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

### What doorway width and ceiling height does RELIANCE WATER HEATERS 10-66-DHPHTNE 1** need?

RELIANCE WATER HEATERS 10-66-DHPHTNE 1** stands 61 in. high with a 23 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does RELIANCE WATER HEATERS 10-66-DHPHTNE 1** require?

RELIANCE WATER HEATERS 10-66-DHPHTNE 1** uses a 240V branch circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

### How much electricity or energy does RELIANCE WATER HEATERS 10-66-DHPHTNE 1** cost per year to run?

Rated at 1,381 kWh/yr, RELIANCE WATER HEATERS 10-66-DHPHTNE 1** costs about $251/yr ($2,510 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $202/yr in Washington hydro tiers up to $652/yr in Hawaii).

### Who should NOT install RELIANCE WATER HEATERS 10-66-DHPHTNE 1**, and what are its limits?

RELIANCE WATER HEATERS 10-66-DHPHTNE 1** (3.45 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

### How many bathrooms or people can RELIANCE WATER HEATERS 10-66-DHPHTNE 1** serve at peak demand?

RELIANCE WATER HEATERS 10-66-DHPHTNE 1** achieves a 79 gal First Hour Rating (+7 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for RELIANCE WATER HEATERS 10-66-DHPHTNE 1**?

CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What 2026 rebates apply to RELIANCE WATER HEATERS 10-66-DHPHTNE 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPTU-66CTA 1** (3.45 UEF).

## Essential Pre-Install Guides for RELIANCE WATER HEATERS 10-66-DHPHTNE 1**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith HPTU-66CTA 1** (3.45 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hptu-66cta-1/)
- [Compare American HPHE10266H045DVCTA-1** (3.45 UEF)→](https://gcsradheat.com/water-heaters/american/hphe10266h045dvcta-1/)
- [View All RELIANCE WATER HEATERS Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/reliance-water-heaters/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)