title: "RELIANCE WATER HEATERS 6-66-DHPHT 1** (3.42 UEF, 67 gal)"
url: https://gcsradheat.com/water-heaters/reliance-water-heaters/6-66-dhpht-1/
description: "In the 706-unit Hybrid/Electric Heat Pump class, RELIANCE WATER HEATERS 6-66-DHPHT 1** (Electric) achieves a certified 3.42 UEF rating across its 67-gallon."
---

ENERGY STAR water heater model · PD 2408899

# RELIANCE WATER HEATERS 6-66-DHPHT 1** Water Heater Specifications (3.42 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, RELIANCE WATER HEATERS 6-66-DHPHT 1** (Electric) achieves a certified 3.42 UEF rating across its 67-gallon nominal tank, 79 gal First Hour Rating (rank #624 of 706, PD 2408899) and verifies as Pass: +0.92 / +36.8% for 2029 DOE floors. Rated annual electricity draw of 1,391 kWh/yr equates to roughly $253/yr ($2,526 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith FPTU-66 1** (3.42 UEF).

- **Uniform Energy Factor**: 3.42 UEF

- **Cohort UEF Rank**: #624 of 706

- **First Hour Rating**: 79 gal

- **Storage Volume**: 67 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.92 / +36.8%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows RELIANCE WATER HEATERS 6-66-DHPHT 1** relative to the cohort median.

Efficiency comparison & rule summary

RELIANCE WATER HEATERS 6-66-DHPHT 1** records 3.42 UEF efficiency, putting it #624 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: RELIANCE WATER HEATERS 6-66-DHPHT 1** exceeds 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.92 UEF (+36.8%). At EIA August 2026 national rates (18.16 cents/kWh), 1,391 kWh/yr for RELIANCE WATER HEATERS 6-66-DHPHT 1** runs ~$253/yr vs. ~$939/yr for a 0.92 UEF electric tank.

State electric sensitivity for RELIANCE WATER HEATERS 6-66-DHPHT 1**: 10-year operating spend spans $2,035 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,563 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside RELIANCE WATER HEATERS 6-66-DHPHT 1** (3.42 UEF) are A. O. Smith FPTU-66 1** (3.42 UEF, at parity) and American HPHE6266H045DV 1** (3.42 UEF, at parity).

## What Physical and Thermal Ratings Define RELIANCE WATER HEATERS 6-66-DHPHT 1**?

Positioning at #624 of 706 out of 706 Hybrid/Electric Heat Pump peers, RELIANCE WATER HEATERS 6-66-DHPHT 1** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [RELIANCE WATER HEATERS](https://gcsradheat.com/brands/reliance-water-heaters/) | 71 certified listings | ENERGY STAR PD 2408899 |
| Model Number | 6-66-DHPHT 1** | Draw pattern: High-Usage | 6-66-DHPHT 1** |
| Uniform Energy Factor (UEF) | 3.42 | -0.28 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 79 gal | +7 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,391 kWh/yr | +319 kWh/yr vs. 1,072 kWh/yr median | Est. $253/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 265% | -164.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61" H x 23" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States |

## Why Do State Utility Rates Shift 6-66-DHPHT 1** Running Costs?

Consuming 1,391 kWh annually puts RELIANCE WATER HEATERS 6-66-DHPHT 1** near $253/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $253/yr | $2,526 | $6,864 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $656/yr | $6,563 | $17,834 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $414/yr | $4,138 | $11,246 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $221/yr | $2,213 | $6,014 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $204/yr | $2,035 | $5,530 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,391 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any RELIANCE WATER HEATERS Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 3 brand notices under RELIANCE WATER HEATERS; inspect model coverage dates prior to valve or anode service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**3 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #04128 (2004-04-28):** CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls ([CPSC Notice](https://www.cpsc.gov/Recalls/2004/CPSC-White-Rodgers-Announce-Recall-of-LP-and-Convertible-Gas-Water-Heater-Temperature-Controls-))

## What Are 5 Direct Alternatives to RELIANCE WATER HEATERS 6-66-DHPHT 1**?

Homeowners cross-shopping RELIANCE WATER HEATERS 6-66-DHPHT 1** frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith FPTU-66 1**](https://gcsradheat.com/water-heaters/a-o-smith/fptu-66-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.42 (at parity) | 1,391 |
| [American HPHE6266H045DV 1**](https://gcsradheat.com/water-heaters/american/hphe6266h045dv-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.42 (at parity) | 1,391 |
| [State HP6-66-DHPT 1**](https://gcsradheat.com/water-heaters/state/hp6-66-dhpt-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.42 (at parity) | 1,391 |
| [U.S. Craftmaster HPHE2F66HD045VU 1**](https://gcsradheat.com/water-heaters/u-s-craftmaster/hphe2f66hd045vu-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.42 (at parity) | 1,391 |
| [A. O. Smith HPTU-66CTA 1**](https://gcsradheat.com/water-heaters/a-o-smith/hptu-66cta-1/) | Hybrid/Electric Heat Pump | 67 gal | 79 gal | 3.45 (+0.03) | 1,381 |

## When Should Homeowners Skip RELIANCE WATER HEATERS 6-66-DHPHT 1** (Hybrid/Electric Heat Pump)?

Check RELIANCE WATER HEATERS 6-66-DHPHT 1**'s mechanical constraints—including utility space, Electric capacity, and Pass: +0.92 / +36.8% status—against typical residential installations.

### Key Limitations & Exclusions

- RELIANCE WATER HEATERS 6-66-DHPHT 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting RELIANCE WATER HEATERS 6-66-DHPHT 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing RELIANCE WATER HEATERS 6-66-DHPHT 1 Strong Fit — 3.42 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith FPTU-66 1** footprint.

## Sizing, Efficiency & Recall Answers for RELIANCE WATER HEATERS 6-66-DHPHT 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Will RELIANCE WATER HEATERS 6-66-DHPHT 1** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 3.42 UEF, RELIANCE WATER HEATERS 6-66-DHPHT 1** shows Pass: +0.92 / +36.8% relative to May 6, 2029 federal DOE limits while placing #624 of 706 among 706 Hybrid/Electric Heat Pump peers like A. O. Smith FPTU-66 1**.

### Will RELIANCE WATER HEATERS 6-66-DHPHT 1** fit through a standard utility door and 72-inch basement ceiling?

Measuring 61 in. tall by 23 in. diameter, RELIANCE WATER HEATERS 6-66-DHPHT 1** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (23" d). Reserve space above the jacket for T&P piping and anode removal.

### Do existing utility hookups support RELIANCE WATER HEATERS 6-66-DHPHT 1** during replacement?

Electrical specs for RELIANCE WATER HEATERS 6-66-DHPHT 1** call for 240V at 22A max (Requires 240V dedicated branch circuit; check panel capacity). Have a licensed electrician inspect panel load and wire gauge.

### What is the estimated 10-year operating spend for RELIANCE WATER HEATERS 6-66-DHPHT 1**?

At 18.16 cents/kWh national residential pricing, RELIANCE WATER HEATERS 6-66-DHPHT 1**'s 1,391 kWh/yr draw equals roughly $253 annually or $2,530 across a 10-year horizon (ranging from $204/yr in Washington hydro tiers up to $656/yr in Hawaii).

### When is RELIANCE WATER HEATERS 6-66-DHPHT 1** a poor fit for a residential replacement?

Avoid placing RELIANCE WATER HEATERS 6-66-DHPHT 1** directly next to bedrooms or inside tight <300 cu ft closets without ducting, due to 49 dBA sound and cool exhaust airflow.

### What First Hour Rating or flow capacity does RELIANCE WATER HEATERS 6-66-DHPHT 1** deliver?

With 79 gal FHR (+7 gal vs. 72 gal median), RELIANCE WATER HEATERS 6-66-DHPHT 1** fits larger 3–5 person homes cleanly.

### How do you verify manufacturing age and recall status on RELIANCE WATER HEATERS 6-66-DHPHT 1**?

CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### Does RELIANCE WATER HEATERS 6-66-DHPHT 1** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for RELIANCE WATER HEATERS 6-66-DHPHT 1**. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith FPTU-66 1** (3.42 UEF).

## Related Rebate, Gas-Line & Serial Tools for 6-66-DHPHT 1**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith FPTU-66 1** (3.42 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/fptu-66-1/)
- [Compare American HPHE6266H045DV 1** (3.42 UEF)→](https://gcsradheat.com/water-heaters/american/hphe6266h045dv-1/)
- [View All RELIANCE WATER HEATERS Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/reliance-water-heaters/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)