title: "RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** (3.7 UEF, 60"
url: https://gcsradheat.com/water-heaters/reliance-water-heaters/rhpco-45-1-rxst-66-1/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** achieves a certified 3.7 UEF rating across its."
---

ENERGY STAR water heater model · PD 4529447

# RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** Water Heater Specifications (3.7 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** achieves a certified 3.7 UEF rating across its 60-gallon nominal tank, 82 gal First Hour Rating and ranks #347 of 706 in its 706-model cohort (PD 4529447), recording Pass: +1.20 / +48.0% under 2029 DOE rules. Rated annual electricity draw of 1,341 kWh/yr equates to roughly $244/yr ($2,435 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF).

- **Uniform Energy Factor**: 3.7 UEF

- **Cohort UEF Rank**: #347 of 706

- **First Hour Rating**: 82 gal

- **Storage Volume**: 60 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.20 / +48.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** logs 3.7 UEF and ranks #347 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** holds a +1.20 UEF (+48.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 1,341 kWh/yr for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** runs ~$244/yr vs. ~$979/yr for a 0.92 UEF electric tank.

State electric sensitivity for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1**: 10-year operating spend spans $1,962 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,327 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** (3.7 UEF)? Check A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF, at parity) and American MHPCO-45 1**+MXST-66 1** (3.7 UEF, at parity).

## How Complete Are the Certified Metrics for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1**?

Standing at #347 of 706 among 706 certified Hybrid/Electric Heat Pump heaters, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [RELIANCE WATER HEATERS](https://gcsradheat.com/brands/reliance-water-heaters/) | 71 certified listings | ENERGY STAR PD 4529447 |
| Model Number | RHPCO-45 1**+RXST-66 1** | Draw pattern: High-Usage | RHPCO-45 1**+RXST-66 1** |
| Uniform Energy Factor (UEF) | 3.7 | At 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 82 gal | +10 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,341 kWh/yr | +269 kWh/yr vs. 1,072 kWh/yr median | Est. $244/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 435% | +6.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 59" H x 18" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 20.2 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-744 (CO₂) (GWP:1 / Lower GWP) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2026-02-25 | Certified 2026-02-25 | Markets: United States |

## What Is the Projected Utility Bill for RHPCO-45 1**+RXST-66 1** by State?

At 1,341 kWh/yr, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** averages about $244/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $244/yr | $2,435 | $7,358 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $633/yr | $6,327 | $19,117 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $399/yr | $3,989 | $12,055 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $213/yr | $2,134 | $6,447 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $196/yr | $1,962 | $5,928 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,341 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are RELIANCE WATER HEATERS Models Affected by Current CPSC Notices?

Review 3 brand-matched CPSC entries pulled 2026-11-23 for RELIANCE WATER HEATERS and confirm your serial tag before scheduling contractor service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**3 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #04128 (2004-04-28):** CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls ([CPSC Notice](https://www.cpsc.gov/Recalls/2004/CPSC-White-Rodgers-Announce-Recall-of-LP-and-Convertible-Gas-Water-Heater-Temperature-Controls-))

## Which 5 Models Offer Similar Output to RHPCO-45 1**+RXST-66 1**?

Ordered by minimal capacity and UEF spread relative to RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1**, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith HPACO-45 1**+AXST-66 1**](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-66-1/) | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
| [American MHPCO-45 1**+MXST-66 1**](https://gcsradheat.com/water-heaters/american/mhpco-45-1-mxst-66-1/) | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
| [Giant GTHPCO-45 1**+GTXST-66 1**](https://gcsradheat.com/water-heaters/giant/gthpco-45-1-gtxst-66-1/) | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
| [GSW WATER HEATERS GHPCO-45 1**+GXST-66 1**](https://gcsradheat.com/water-heaters/gsw-water-heaters/ghpco-45-1-gxst-66-1/) | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |
| [A. O. Smith HPACO-45 1**+AXST-66TTP 1**](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-66ttp-1/) | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (at parity) | 1,341 |

## What Are the Limitations of RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** and Who Should Not Install It?

Before ordering RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** (Hybrid/Electric Heat Pump, 3.7 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1 Strong Fit — 3.7 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-66 1** footprint.

## Practical Specs & Code Questions for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** pass the May 6, 2029 federal DOE efficiency rule?

RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** carries a verified 3.7 UEF rating (Pass: +1.20 / +48.0%), ranking #347 of 706 across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

### What doorway width and ceiling height does RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** need?

RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** stands 59 in. high with a 18 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** require?

RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** uses a 240V branch circuit at 20.2A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

### How much electricity or energy does RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** cost per year to run?

Rated at 1,341 kWh/yr, RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** costs about $244/yr ($2,440 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $196/yr in Washington hydro tiers up to $633/yr in Hawaii).

### Who should NOT install RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1**, and what are its limits?

RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** (3.7 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

### How many bathrooms or people can RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** serve at peak demand?

RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1** achieves a 82 gal First Hour Rating (+10 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1**?

CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What 2026 rebates apply to RELIANCE WATER HEATERS RHPCO-45 1**+RXST-66 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF).

## Installation, Serial & DOE 2029 Links for RHPCO-45 1**+RXST-66 1**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith HPACO-45 1**+AXST-66 1** (3.7 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-66-1/)
- [Compare American MHPCO-45 1**+MXST-66 1** (3.7 UEF)→](https://gcsradheat.com/water-heaters/american/mhpco-45-1-mxst-66-1/)
- [View All RELIANCE WATER HEATERS Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/reliance-water-heaters/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)