---
title: "RELIANCE WATER HEATERS RTM-199M-N 1** (0.95 UEF, Gas Tankless)"
url: https://gcsradheat.com/water-heaters/reliance-water-heaters/rtm-199m-n-1/
description: "With PD 4015948 certification, RELIANCE WATER HEATERS RTM-199M-N 1** (Gas Tankless, Natural Gas) achieves a certified 0.95 UEF rating, standing #159 of 464."
---

ENERGY STAR water heater model · PD 4015948

# RELIANCE WATER HEATERS RTM-199M-N 1** Water Heater Specifications (0.95 UEF)

With PD 4015948 certification, RELIANCE WATER HEATERS RTM-199M-N 1** (Gas Tankless, Natural Gas) achieves a certified 0.95 UEF rating, standing #159 of 464 across 464 peers with Pass: +0.04 / +4.4% for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

- **Uniform Energy Factor**: 0.95 UEF

- **Cohort UEF Rank**: #159 of 464

- **First Hour Rating**: On-Demand

- **Storage Volume**: Tankless

- **Fuel / Type**: Natural Gas / Gas Tankless

- **DOE 2029 Rule Status**: Pass: +0.04 / +4.4%

Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils

Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows RELIANCE WATER HEATERS RTM-199M-N 1** relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places RELIANCE WATER HEATERS RTM-199M-N 1** at 0.95 UEF (#159 of 464; At 0.95 UEF median) in Gas Tankless.

With Natural Gas condensing combustion, RELIANCE WATER HEATERS RTM-199M-N 1** stands +0.04 UEF (+4.4%) above the 2029 0.91 UEF minimum; thermal recovery tests at 96% (-2.0 pts vs. 98.0% median).

In the Gas Tankless tier, A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) and American GT-240-NEH 1** (0.95 UEF, at parity) bracket RELIANCE WATER HEATERS RTM-199M-N 1**.

## How Complete Are the Certified Metrics for RELIANCE WATER HEATERS RTM-199M-N 1**?

Standing at #159 of 464 among 464 certified Gas Tankless heaters, RELIANCE WATER HEATERS RTM-199M-N 1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [RELIANCE WATER HEATERS](https://gcsradheat.com/brands/reliance-water-heaters/) | 71 certified listings | ENERGY STAR PD 4015948 |
| Model Number | RTM-199M-N 1** | Draw pattern: High-Usage | RTM-199M-N 1** |
| Uniform Energy Factor (UEF) | 0.95 | At 0.95 UEF median | 10 CFR 430 Test Method |
| Thermal Recovery Efficiency | 96% | -2.0 pts vs. 98.0% median | ENERGY STAR Dataset |
| Electrical Circuit Requirements | 5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2025-04-21 | Certified 2025-04-21 | Markets: United States, Canada |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are RELIANCE WATER HEATERS Models Affected by Current CPSC Notices?

Review 3 brand-matched CPSC entries pulled 2026-11-23 for RELIANCE WATER HEATERS and confirm your serial tag before scheduling contractor service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**3 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #19029 (2018-11-08):** A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2019/A-O-Smith-Recalls-Ultra-Low-NOx-Water-Heaters-Due-to-Fire-Hazard))
- **Recall #06002 (2005-10-06):** CPSC, A.O. Smith Announce Recall of Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2006/CPSC-AO-Smith-Recall-of-Water-Heaters))
- **Recall #04128 (2004-04-28):** CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls ([CPSC Notice](https://www.cpsc.gov/Recalls/2004/CPSC-White-Rodgers-Announce-Recall-of-LP-and-Convertible-Gas-Water-Heater-Temperature-Controls-))

## Which 5 Models Offer Similar Output to RTM-199M-N 1**?

Ordered by minimal capacity and UEF spread relative to RELIANCE WATER HEATERS RTM-199M-N 1**, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [A. O. Smith ACT-199O-N 1**](https://gcsradheat.com/water-heaters/a-o-smith/act-199o-n-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [American GT-240-NEH 1**](https://gcsradheat.com/water-heaters/american/gt-240-neh-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [Bosch T9800 SE 160](https://gcsradheat.com/water-heaters/bosch/t9800-se-160/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [Bradford White RTG-K-160N1](https://gcsradheat.com/water-heaters/bradford-white/rtg-k-160n1/) | Gas Tankless | — | — | 0.95 (at parity) | — |
| [A. O. Smith ACT-199O-P 1*1](https://gcsradheat.com/water-heaters/a-o-smith/act-199o-p-1-1/) | Gas Tankless | — | — | 0.95 (at parity) | — |

## Who Is RELIANCE WATER HEATERS RTM-199M-N 1** Best For — and When Should You Pick A. O. Smith ACT-199O-N 1**?

Evaluate whether RELIANCE WATER HEATERS RTM-199M-N 1**'s Gas Tankless architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- Converting a 40K tank to RELIANCE WATER HEATERS RTM-199M-N 1** often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
- Hard tap water >=7.0 GPG requires annual vinegar descaling to protect RELIANCE WATER HEATERS RTM-199M-N 1**'s heat exchanger.
- Condensing RELIANCE WATER HEATERS RTM-199M-N 1** requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

### Which Option Fits Your Situation?

**Existing 3/4 in.+ Gas Line + Marathon Hot Draws** Strong Fit — RELIANCE WATER HEATERS RTM-199M-N 1** delivers continuous 0.95 UEF performance.

**Softened/Low-Scale Water (<7.0 GPG)** Strong Fit — Minimal calcium scale between 12-month flushes.

**Long 1/2 in. Gas Run (>10 ft)** Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

## Practical Specs & Code Questions for RELIANCE WATER HEATERS RTM-199M-N 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does RELIANCE WATER HEATERS RTM-199M-N 1** (0.95 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, RELIANCE WATER HEATERS RTM-199M-N 1** records 0.95 UEF (Pass: +0.04 / +4.4%), placing #159 of 464 out of 464 certified Gas Tankless configurations.

### Does RELIANCE WATER HEATERS RTM-199M-N 1** fit inside a tight hallway closet or low-headroom utility room?

Designed as a compact gas tankless platform (wall-hung / compact envelope), RELIANCE WATER HEATERS RTM-199M-N 1** still needs code-compliant flue separation from windows and gas meters.

### What power supply or fuel line specs govern RELIANCE WATER HEATERS RTM-199M-N 1**?

Installing RELIANCE WATER HEATERS RTM-199M-N 1** on Natural Gas involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.

### What annual utility bill should homeowners budget for RELIANCE WATER HEATERS RTM-199M-N 1**?

Rated 0.95 UEF on Natural Gas, RELIANCE WATER HEATERS RTM-199M-N 1** carries no whole-house kWh heating draw; confirm annual therm usage against 464 Gas Tankless models.

### What are the main drawbacks of RELIANCE WATER HEATERS RTM-199M-N 1** (0.95 UEF)?

Homeowners unwilling to perform 12-month scale flushes in >=7.0 GPG water or upgrade 1/2 in. gas piping should weigh A. O. Smith ACT-199O-N 1** or hybrid alternatives.

### What hot-water delivery rating governs RELIANCE WATER HEATERS RTM-199M-N 1**?

On-demand Gas Tankless sizing for RELIANCE WATER HEATERS RTM-199M-N 1** depends on winter inlet water temp (typically 45–65 °F) heated to a 120 °F anti-scald setpoint.

### Where do homeowners screen RELIANCE WATER HEATERS RTM-199M-N 1** for recalls and tank age?

CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What alternative models sit closest to RELIANCE WATER HEATERS RTM-199M-N 1** in the Gas Tankless class?

Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Installation, Serial & DOE 2029 Links for RTM-199M-N 1**

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare A. O. Smith ACT-199O-N 1** (0.95 UEF)→](https://gcsradheat.com/water-heaters/a-o-smith/act-199o-n-1/)
- [Compare American GT-240-NEH 1** (0.95 UEF)→](https://gcsradheat.com/water-heaters/american/gt-240-neh-1/)
- [View All RELIANCE WATER HEATERS Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/reliance-water-heaters/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)
