title: "Rheem CXE40T10HS45U1 (3.83 UEF, 36 gal)"
url: https://gcsradheat.com/water-heaters/rheem/cxe40t10hs45u1/
description: "Certified at 3.83 UEF across its 36-gallon nominal tank, 60 gal First Hour Rating, Rheem CXE40T10HS45U1 (Hybrid/Electric Heat Pump, Electric) places #230 of."
---

ENERGY STAR water heater model · PD 3554186

# Rheem CXE40T10HS45U1 Water Heater Specifications (3.83 UEF)

Certified at 3.83 UEF across its 36-gallon nominal tank, 60 gal First Hour Rating, Rheem CXE40T10HS45U1 (Hybrid/Electric Heat Pump, Electric) places #230 of 706 out of 706 ENERGY STAR models (PD 3554186). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.53 / +66.5%. Rated annual electricity draw of 859 kWh/yr equates to roughly $156/yr ($1,560 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

- **Uniform Energy Factor**: 3.83 UEF

- **Cohort UEF Rank**: #230 of 706 (top 37.8%)

- **First Hour Rating**: 60 gal

- **Storage Volume**: 36 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.53 / +66.5%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem CXE40T10HS45U1 relative to the cohort median.

Efficiency comparison & rule summary

Tested at 3.83 UEF, Rheem CXE40T10HS45U1 places #230 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (+0.13 UEF vs. 3.70 UEF median).

Rheem CXE40T10HS45U1 clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.53 UEF (+66.5% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 859 kWh/yr for Rheem CXE40T10HS45U1 runs ~$156/yr vs. ~$649/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem CXE40T10HS45U1: 10-year operating spend spans $1,257 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,053 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Rheem CXE40T10HS45U1 include Friedrich PROH40 T2 FD400-30 (3.83 UEF, at parity) alongside Richmond 10CE40-HP5U30 (3.83 UEF, at parity).

## Which Specs Set Rheem CXE40T10HS45U1 Apart From Cohort Averages?

Ranked #230 of 706 (top 37.8%) inside the 706-model Hybrid/Electric Heat Pump cohort, Rheem CXE40T10HS45U1 is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 3554186 |
| Model Number | CXE40T10HS45U1 | Draw pattern: Medium-Usage | CXE40T10HS45U1 |
| Uniform Energy Factor (UEF) | 3.83 | +0.13 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 60 gal | -12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 859 kWh/yr | -213 kWh/yr vs. 1,072 kWh/yr median | Est. $156/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 434% | +5.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |

## How Do Regional kWh Prices Impact CXE40T10HS45U1 Over 10 Years?

Using EIA Table 5.6.A benchmarks, Rheem CXE40T10HS45U1's 859 kWh/yr draw translates to roughly $156/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $156/yr | $1,560 | $4,934 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $405/yr | $4,053 | $12,819 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $256/yr | $2,556 | $8,083 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $137/yr | $1,367 | $4,323 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $126/yr | $1,257 | $3,975 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (859 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should Rheem Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to Rheem; verify whether your CXE40T10HS45U1 production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH40 T2 FD400-30](https://gcsradheat.com/water-heaters/friedrich/proh40-t2-fd400-30/) | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| [Richmond 10CE40-HP5U30](https://gcsradheat.com/water-heaters/richmond/10ce40-hp5u30/) | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| [Ruud CPROPH40 T2 CD375-30](https://gcsradheat.com/water-heaters/ruud/cproph40-t2-cd375-30/) | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| [A. O. Smith CAHP-40 2**](https://gcsradheat.com/water-heaters/a-o-smith/cahp-40-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (-0.23) | 902 |
| [Friedrich PROH40 T2 FD400-SO](https://gcsradheat.com/water-heaters/friedrich/proh40-t2-fd400-so/) | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |

## What Are the Limitations of Rheem CXE40T10HS45U1 and Who Should Not Install It?

Before ordering Rheem CXE40T10HS45U1 (Hybrid/Electric Heat Pump, 3.83 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- Rheem CXE40T10HS45U1 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem CXE40T10HS45U1 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Rheem CXE40T10HS45U1** Strong Fit — 3.83 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH40 T2 FD400-30 footprint.

## Frequently Asked Technical Questions: Rheem CXE40T10HS45U1

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Rheem CXE40T10HS45U1 pass the May 6, 2029 federal DOE efficiency rule?

Rheem CXE40T10HS45U1 carries a verified 3.83 UEF rating (Pass: +1.53 / +66.5%), ranking #230 of 706 (top 37.8%) across 706 ENERGY STAR Hybrid/Electric Heat Pump models under 10 CFR 430.32.

### What doorway width and ceiling height does Rheem CXE40T10HS45U1 need?

Rheem CXE40T10HS45U1 stands 62.3 in. high with a 20.3 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

### What gas pipe size or electrical breaker does Rheem CXE40T10HS45U1 require?

Rheem CXE40T10HS45U1 uses a 240V branch circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity). Verify main breaker space before replacing a gas tank with an electric hybrid unit.

### How much electricity or energy does Rheem CXE40T10HS45U1 cost per year to run?

Rated at 859 kWh/yr, Rheem CXE40T10HS45U1 costs about $156/yr ($1,560 over 10 years) at the August 2026 EIA US average of 18.16 cents/kWh (ranging from $126/yr in Washington hydro tiers up to $405/yr in Hawaii).

### Who should NOT install Rheem CXE40T10HS45U1, and what are its limits?

Rheem CXE40T10HS45U1 (3.83 UEF) is a poor fit for unvented closets under 450 cu ft because compressor intake chills enclosed rooms and runs at 49 dBA.

### How many bathrooms or people can Rheem CXE40T10HS45U1 serve at peak demand?

Rheem CXE40T10HS45U1 achieves a 60 gal First Hour Rating (-12 gal vs. 72 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

### Are there CPSC safety recalls or serial checks for Rheem CXE40T10HS45U1?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What 2026 rebates apply to Rheem CXE40T10HS45U1, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

## Essential Pre-Install Guides for Rheem CXE40T10HS45U1

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH40 T2 FD400-30 (3.83 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh40-t2-fd400-30/)
- [Compare Richmond 10CE40-HP5U30 (3.83 UEF)→](https://gcsradheat.com/water-heaters/richmond/10ce40-hp5u30/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)