title: "Rheem CXE50T10H45U1 (3.88 UEF, 45 gal)"
url: https://gcsradheat.com/water-heaters/rheem/cxe50t10h45u1/
description: "The Rheem CXE50T10H45U1 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.88 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating."
---

ENERGY STAR water heater model · PD 3554205

# Rheem CXE50T10H45U1 Water Heater Specifications (3.88 UEF)

The Rheem CXE50T10H45U1 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.88 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating, ranking #165 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3554205). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.58 / +68.7%. Rated annual electricity draw of 846 kWh/yr equates to roughly $154/yr ($1,536 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD400-30 (3.88 UEF).

- **Uniform Energy Factor**: 3.88 UEF

- **Cohort UEF Rank**: #165 of 706 (top 30.6%)

- **First Hour Rating**: 67 gal

- **Storage Volume**: 45 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.58 / +68.7%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem CXE50T10H45U1 relative to the cohort median.

Efficiency comparison & rule summary

Rheem CXE50T10H45U1 (3.88 UEF) ranks #165 of 706 Hybrid/Electric Heat Pump models — 52-way tie; top 30.6%, more efficient than 69.4% of Hybrid/Electric Heat Pump models, +0.18 UEF above the 3.70 UEF median.

Federal 2029 margin for Rheem CXE50T10H45U1: +1.58 UEF (+68.7%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 846 kWh/yr for Rheem CXE50T10H45U1 runs ~$154/yr vs. ~$648/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem CXE50T10H45U1: 10-year operating spend spans $1,238 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,991 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Rheem CXE50T10H45U1 (3.88 UEF) compares closely with Friedrich PROH50 T2 FD400-30 (3.88 UEF, at parity) and Richmond 10CE50-HP5S30 (3.88 UEF, at parity).

## Where Does Rheem CXE50T10H45U1 Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Rheem CXE50T10H45U1 holds #165 of 706 (top 30.6%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 3554205 |
| Model Number | CXE50T10H45U1 | Draw pattern: Medium-Usage | CXE50T10H45U1 |
| Uniform Energy Factor (UEF) | 3.88 | +0.18 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 846 kWh/yr | -226 kWh/yr vs. 1,072 kWh/yr median | Est. $154/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61.8" H x 22.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |

## How Much Electricity Does CXE50T10H45U1 Use in Different States?

Estimated at $154/yr nationally (846 kWh/yr), 10-year utility spending for Rheem CXE50T10H45U1 shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $154/yr | $1,536 | $4,943 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $399/yr | $3,991 | $12,842 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $252/yr | $2,517 | $8,098 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $135/yr | $1,346 | $4,331 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $124/yr | $1,238 | $3,982 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (846 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on Rheem Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning Rheem; always cross-reference affected serial prefixes before ordering components. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to CXE50T10H45U1?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Rheem CXE50T10H45U1's gallon capacity and 3.88 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH50 T2 FD400-30](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd400-30/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| [Richmond 10CE50-HP5S30](https://gcsradheat.com/water-heaters/richmond/10ce50-hp5s30/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| [Ruud CPROPH50 T2 CD375-30](https://gcsradheat.com/water-heaters/ruud/cproph50-t2-cd375-30/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| [Bradford White RE2HP50**-1NCTT](https://gcsradheat.com/water-heaters/bradford-white/re2hp50-1nctt/) | Hybrid/Electric Heat Pump | 45 gal | 65 gal | 3.89 (+0.01) | 835 |
| [Friedrich PROH50 T2 FD400-SO](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd400-so/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |

## Who Is Rheem CXE50T10H45U1 Best For — and When Should You Pick Friedrich PROH50 T2 FD400-30?

Evaluate whether Rheem CXE50T10H45U1's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- Rheem CXE50T10H45U1 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem CXE50T10H45U1 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Rheem CXE50T10H45U1** Strong Fit — 3.88 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH50 T2 FD400-30 footprint.

## Common Homeowner Questions for Rheem CXE50T10H45U1

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Rheem CXE50T10H45U1 (3.88 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Rheem CXE50T10H45U1 records 3.88 UEF (Pass: +1.58 / +68.7%), placing #165 of 706 (top 30.6%) out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does Rheem CXE50T10H45U1 fit inside a tight hallway closet or low-headroom utility room?

Rheem CXE50T10H45U1 requires room for its 61.8 in. vertical shell and 22.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern Rheem CXE50T10H45U1?

For Rheem CXE50T10H45U1, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for Rheem CXE50T10H45U1?

Using 846 kWh/yr, Rheem CXE50T10H45U1 generates an estimated $154/yr electric bill at 18.16 cents/kWh (ranging from $124/yr in Washington hydro tiers up to $399/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of Rheem CXE50T10H45U1 (3.88 UEF)?

Rheem CXE50T10H45U1 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH50 T2 FD400-30.

### What hot-water delivery rating governs Rheem CXE50T10H45U1?

Rated for 67 gal FHR (-5 gal vs. 72 gal median), Rheem CXE50T10H45U1 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen Rheem CXE50T10H45U1 for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What alternative models sit closest to Rheem CXE50T10H45U1 in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD400-30 (3.88 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Next Engineering Checks for Rheem Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH50 T2 FD400-30 (3.88 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd400-30/)
- [Compare Richmond 10CE50-HP5S30 (3.88 UEF)→](https://gcsradheat.com/water-heaters/richmond/10ce50-hp5s30/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)