title: "Rheem CXE50T10HS45U1 (3.88 UEF, 45 gal)"
url: https://gcsradheat.com/water-heaters/rheem/cxe50t10hs45u1/
description: "With PD 3554208 certification, Rheem CXE50T10HS45U1 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.88 UEF rating across its 45-gallon nominal."
---

ENERGY STAR water heater model · PD 3554208

# Rheem CXE50T10HS45U1 Water Heater Specifications (3.88 UEF)

With PD 3554208 certification, Rheem CXE50T10HS45U1 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.88 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating, standing #165 of 706 across 706 peers with Pass: +1.58 / +68.7% for May 6, 2029. Rated annual electricity draw of 846 kWh/yr equates to roughly $154/yr ($1,536 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD400-30 (3.88 UEF).

- **Uniform Energy Factor**: 3.88 UEF

- **Cohort UEF Rank**: #165 of 706 (top 30.6%)

- **First Hour Rating**: 67 gal

- **Storage Volume**: 45 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.58 / +68.7%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem CXE50T10HS45U1 relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places Rheem CXE50T10HS45U1 at 3.88 UEF (#165 of 706; +0.18 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Rheem CXE50T10HS45U1 stands +1.58 UEF (+68.7%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 846 kWh/yr for Rheem CXE50T10HS45U1 runs ~$154/yr vs. ~$648/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem CXE50T10HS45U1: 10-year operating spend spans $1,238 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,991 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Friedrich PROH50 T2 FD400-30 (3.88 UEF, at parity) and Richmond 10CE50-HP5S30 (3.88 UEF, at parity) bracket Rheem CXE50T10HS45U1.

## What Physical and Thermal Ratings Define Rheem CXE50T10HS45U1?

Positioning at #165 of 706 (top 30.6%) out of 706 Hybrid/Electric Heat Pump peers, Rheem CXE50T10HS45U1 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 3554208 |
| Model Number | CXE50T10HS45U1 | Draw pattern: Medium-Usage | CXE50T10HS45U1 |
| Uniform Energy Factor (UEF) | 3.88 | +0.18 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 846 kWh/yr | -226 kWh/yr vs. 1,072 kWh/yr median | Est. $154/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 430% | +1.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61.8" H x 22.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |

## Why Do State Utility Rates Shift CXE50T10HS45U1 Running Costs?

Consuming 846 kWh annually puts Rheem CXE50T10HS45U1 near $154/yr at US baseline tariffs, with multi-state EIA comparisons charted below.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $154/yr | $1,536 | $4,943 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $399/yr | $3,991 | $12,842 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $252/yr | $2,517 | $8,098 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $135/yr | $1,346 | $4,331 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $124/yr | $1,238 | $3,982 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (846 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Have Any Rheem Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 4 brand notices under Rheem; inspect model coverage dates prior to valve or anode service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## What Are 5 Direct Alternatives to Rheem CXE50T10HS45U1?

Homeowners cross-shopping Rheem CXE50T10HS45U1 frequently review these five Hybrid/Electric Heat Pump models ranked closest on capacity and UEF output.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH50 T2 FD400-30](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd400-30/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| [Richmond 10CE50-HP5S30](https://gcsradheat.com/water-heaters/richmond/10ce50-hp5s30/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| [Ruud CPROPH50 T2 CD375-30](https://gcsradheat.com/water-heaters/ruud/cproph50-t2-cd375-30/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |
| [Bradford White RE2HP50**-1NCTT](https://gcsradheat.com/water-heaters/bradford-white/re2hp50-1nctt/) | Hybrid/Electric Heat Pump | 45 gal | 65 gal | 3.89 (+0.01) | 835 |
| [Friedrich PROH50 T2 FD400-SO](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd400-so/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.88 (at parity) | 846 |

## What Installation Caveats Apply Before Buying Rheem CXE50T10HS45U1?

Even high-UEF units like Rheem CXE50T10HS45U1 (3.88 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Rheem CXE50T10HS45U1 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem CXE50T10HS45U1 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Rheem CXE50T10HS45U1** Strong Fit — 3.88 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH50 T2 FD400-30 footprint.

## Sizing, Efficiency & Recall Answers for Rheem CXE50T10HS45U1

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Rheem CXE50T10HS45U1 eligible for continued manufacture past May 6, 2029?

At 3.88 UEF, Rheem CXE50T10HS45U1 achieves Pass: +1.58 / +68.7% for the 2029 DOE standard and stands #165 of 706 (top 30.6%) against Friedrich PROH50 T2 FD400-30 and Richmond 10CE50-HP5S30.

### How tall and wide is Rheem CXE50T10HS45U1, and what service clearance is needed?

Physical dimensions for Rheem CXE50T10HS45U1 are 61.8 in. height and 22.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d)); verify stair turns and drain pan width before delivery.

### Will Rheem CXE50T10HS45U1 require upgrading household electrical panels or gas piping?

Rheem CXE50T10HS45U1 draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is Rheem CXE50T10HS45U1 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $154/yr ($1,540 over 10 years) to power Rheem CXE50T10HS45U1 at 846 kWh/yr under the 18.16 cents/kWh US average (ranging from $124/yr in Washington hydro tiers up to $399/yr in Hawaii).

### Which installation bottlenecks limit Rheem CXE50T10HS45U1?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Rheem CXE50T10HS45U1 drops into resistance mode more often.

### How does Rheem CXE50T10HS45U1 handle simultaneous showers and laundry?

Delivering 67 gal in the first hour (-5 gal vs. 72 gal median), Rheem CXE50T10HS45U1 combines 45 gal tank storage with rapid burner/element recovery.

### How long is the warranty on Rheem CXE50T10HS45U1 and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### How do 2026 post-OBBBA rebates affect buying Rheem CXE50T10HS45U1?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD400-30 (3.88 UEF).

## Related Rebate, Gas-Line & Serial Tools for CXE50T10HS45U1

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH50 T2 FD400-30 (3.88 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd400-30/)
- [Compare Richmond 10CE50-HP5S30 (3.88 UEF)→](https://gcsradheat.com/water-heaters/richmond/10ce50-hp5s30/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)