title: "Rheem CXE80T10HS45U1 (4.07 UEF, 72 gal)"
url: https://gcsradheat.com/water-heaters/rheem/cxe80t10hs45u1/
description: "The Rheem CXE80T10HS45U1 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.07 UEF rating across its 72-gallon nominal tank, 87 gal First Hour."
---

ENERGY STAR water heater model · PD 3554255

# Rheem CXE80T10HS45U1 Water Heater Specifications (4.07 UEF)

The Rheem CXE80T10HS45U1 (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.07 UEF rating across its 72-gallon nominal tank, 87 gal First Hour Rating, ranking #26 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3554255). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.57 / +62.8%. Rated annual electricity draw of 1,213 kWh/yr equates to roughly $220/yr ($2,203 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH80 T2 FD400-30 (4.07 UEF).

- **Uniform Energy Factor**: 4.07 UEF

- **Cohort UEF Rank**: #26 of 706 (top 8.5%)

- **First Hour Rating**: 87 gal

- **Storage Volume**: 72 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.57 / +62.8%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem CXE80T10HS45U1 relative to the cohort median.

Efficiency comparison & rule summary

Rheem CXE80T10HS45U1 (4.07 UEF) ranks #26 of 706 Hybrid/Electric Heat Pump models — 35-way tie; top 8.5%, more efficient than 91.5% of Hybrid/Electric Heat Pump models, +0.37 UEF above the 3.70 UEF median.

Federal 2029 margin for Rheem CXE80T10HS45U1: +1.57 UEF (+62.8%) vs. 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,213 kWh/yr for Rheem CXE80T10HS45U1 runs ~$220/yr vs. ~$974/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem CXE80T10HS45U1: 10-year operating spend spans $1,775 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,723 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Rheem CXE80T10HS45U1 (4.07 UEF) compares closely with Friedrich PROH80 T2 FD400-30 (4.07 UEF, at parity) and Richmond 10CE80-HP5S30 (4.07 UEF, at parity).

## Which Specs Set Rheem CXE80T10HS45U1 Apart From Cohort Averages?

Ranked #26 of 706 (top 8.5%) inside the 706-model Hybrid/Electric Heat Pump cohort, Rheem CXE80T10HS45U1 is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 3554255 |
| Model Number | CXE80T10HS45U1 | Draw pattern: High-Usage | CXE80T10HS45U1 |
| Uniform Energy Factor (UEF) | 4.07 | +0.37 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 87 gal | +15 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,213 kWh/yr | +141 kWh/yr vs. 1,072 kWh/yr median | Est. $220/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 447% | +18.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 74.2" H x 24.3" D | Needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |

## How Do Regional kWh Prices Impact CXE80T10HS45U1 Over 10 Years?

Using EIA Table 5.6.A benchmarks, Rheem CXE80T10HS45U1's 1,213 kWh/yr draw translates to roughly $220/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $220/yr | $2,203 | $7,542 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $572/yr | $5,723 | $19,594 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $361/yr | $3,609 | $12,355 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $193/yr | $1,930 | $6,607 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $177/yr | $1,775 | $6,076 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (1,213 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should Rheem Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to Rheem; verify whether your CXE80T10HS45U1 production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH80 T2 FD400-30](https://gcsradheat.com/water-heaters/friedrich/proh80-t2-fd400-30/) | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| [Richmond 10CE80-HP5S30](https://gcsradheat.com/water-heaters/richmond/10ce80-hp5s30/) | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| [Ruud CPROPH80 T2 CD375-30](https://gcsradheat.com/water-heaters/ruud/cproph80-t2-cd375-30/) | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |
| [LG APHWC802D](https://gcsradheat.com/water-heaters/lg/aphwc802d/) | Hybrid/Electric Heat Pump | 72 gal | 91 gal | 4.1 (+0.03) | 1,210 |
| [Friedrich PROH80 T2 FD400-SO](https://gcsradheat.com/water-heaters/friedrich/proh80-t2-fd400-so/) | Hybrid/Electric Heat Pump | 72 gal | 87 gal | 4.07 (at parity) | 1,213 |

## Which Home Setups Are NOT a Fit for Rheem CXE80T10HS45U1?

Comparing Rheem CXE80T10HS45U1 against Friedrich PROH80 T2 FD400-30 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- Rheem CXE80T10HS45U1 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem CXE80T10HS45U1 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Rheem CXE80T10HS45U1** Strong Fit — 4.07 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH80 T2 FD400-30 footprint.

## Frequently Asked Technical Questions: Rheem CXE80T10HS45U1

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Rheem CXE80T10HS45U1 score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Rheem CXE80T10HS45U1 logs 4.07 UEF (Pass: +1.57 / +62.8%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing Rheem CXE80T10HS45U1?

With a 74.2 in. height and 24.3 in. diameter, Rheem CXE80T10HS45U1 fits spaces matching: needs >72 in. overhead clearance; clears 28 in. utility doorway (24.3" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits Rheem CXE80T10HS45U1?

Powered via 240V at 21A max, Rheem CXE80T10HS45U1 requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for Rheem CXE80T10HS45U1?

Annual electric spend for Rheem CXE80T10HS45U1 (1,213 kWh/yr) averages $220/yr nationwide (ranging from $177/yr in Washington hydro tiers up to $572/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing Rheem CXE80T10HS45U1?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Rheem CXE80T10HS45U1.

### Is Rheem CXE80T10HS45U1 sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Rheem CXE80T10HS45U1 at 87 gal First Hour Rating (+15 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does Rheem have active CPSC SaferProducts notices affecting CXE80T10HS45U1?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### Which competing water heater matches Rheem CXE80T10HS45U1 (4.07 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Rheem CXE80T10HS45U1. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH80 T2 FD400-30 (4.07 UEF).

## Essential Pre-Install Guides for Rheem CXE80T10HS45U1

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH80 T2 FD400-30 (4.07 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh80-t2-fd400-30/)
- [Compare Richmond 10CE80-HP5S30 (4.07 UEF)→](https://gcsradheat.com/water-heaters/richmond/10ce80-hp5s30/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)