title: "Rheem ECEPH65 T2 RH350BM (3.5 UEF, 59 gal)"
url: https://gcsradheat.com/water-heaters/rheem/eceph65-t2-rh350bm/
description: "Certified at 3.5 UEF across its 59-gallon nominal tank, 75 gal First Hour Rating, Rheem ECEPH65 T2 RH350BM (Hybrid/Electric Heat Pump, Electric) places #481 of."
---

ENERGY STAR water heater model · PD 3994191

# Rheem ECEPH65 T2 RH350BM Water Heater Specifications (3.5 UEF)

Certified at 3.5 UEF across its 59-gallon nominal tank, 75 gal First Hour Rating, Rheem ECEPH65 T2 RH350BM (Hybrid/Electric Heat Pump, Electric) places #481 of 706 out of 706 ENERGY STAR models (PD 3994191). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.00 / +40.0%. Rated annual electricity draw of 900 kWh/yr equates to roughly $163/yr ($1,634 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD310BM (3.5 UEF).

- **Uniform Energy Factor**: 3.5 UEF

- **Cohort UEF Rank**: #481 of 706

- **First Hour Rating**: 75 gal

- **Storage Volume**: 59 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.00 / +40.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem ECEPH65 T2 RH350BM relative to the cohort median.

Efficiency comparison & rule summary

Tested at 3.5 UEF, Rheem ECEPH65 T2 RH350BM places #481 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.20 UEF vs. 3.70 UEF median).

Rheem ECEPH65 T2 RH350BM clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +1.00 UEF (+40.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 900 kWh/yr for Rheem ECEPH65 T2 RH350BM runs ~$163/yr vs. ~$622/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem ECEPH65 T2 RH350BM: 10-year operating spend spans $1,317 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,246 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Rheem ECEPH65 T2 RH350BM include Friedrich PROH65 T2 FD310BM (3.5 UEF, at parity) alongside Ruud PRO H65 T2 RU310BM (3.5 UEF, at parity).

## Where Does Rheem ECEPH65 T2 RH350BM Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Rheem ECEPH65 T2 RH350BM holds #481 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 3994191 |
| Model Number | ECEPH65 T2 RH350BM | Draw pattern: High-Usage | ECEPH65 T2 RH350BM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 75 gal | +3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 900 kWh/yr | -172 kWh/yr vs. 1,072 kWh/yr median | Est. $163/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 409% | -20.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: Canada |

## How Much Electricity Does ECEPH65 T2 RH350BM Use in Different States?

Estimated at $163/yr nationally (900 kWh/yr), 10-year utility spending for Rheem ECEPH65 T2 RH350BM shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $163/yr | $1,634 | $4,584 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $425/yr | $4,246 | $11,908 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $268/yr | $2,678 | $7,509 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $143/yr | $1,432 | $4,016 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $132/yr | $1,317 | $3,693 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (900 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on Rheem Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning Rheem; always cross-reference affected serial prefixes before ordering components. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to ECEPH65 T2 RH350BM?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Rheem ECEPH65 T2 RH350BM's gallon capacity and 3.5 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH65 T2 FD310BM](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd310bm/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (at parity) | 900 |
| [Ruud PRO H65 T2 RU310BM](https://gcsradheat.com/water-heaters/ruud/pro-h65-t2-ru310bm/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (at parity) | 900 |
| [Richmond 10CE65-HP5U15](https://gcsradheat.com/water-heaters/richmond/10ce65-hp5u15/) | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (+0.05) | 887 |
| [A. O. Smith HPACO-45 1**+AXST-66 1**](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-66-1/) | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (+0.20) | 1,341 |
| [Friedrich PROH65 T2 FD310UM](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd310um/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (at parity) | 900 |

## Who Is Rheem ECEPH65 T2 RH350BM Best For — and When Should You Pick Friedrich PROH65 T2 FD310BM?

Evaluate whether Rheem ECEPH65 T2 RH350BM's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- Rheem ECEPH65 T2 RH350BM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem ECEPH65 T2 RH350BM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Rheem ECEPH65 T2 RH350BM** Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH65 T2 FD310BM footprint.

## Common Homeowner Questions for Rheem ECEPH65 T2 RH350BM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Rheem ECEPH65 T2 RH350BM (3.5 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Rheem ECEPH65 T2 RH350BM records 3.5 UEF (Pass: +1.00 / +40.0%), placing #481 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does Rheem ECEPH65 T2 RH350BM fit inside a tight hallway closet or low-headroom utility room?

Rheem ECEPH65 T2 RH350BM requires room for its 64.2 in. vertical shell and 24.3 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern Rheem ECEPH65 T2 RH350BM?

For Rheem ECEPH65 T2 RH350BM, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for Rheem ECEPH65 T2 RH350BM?

Using 900 kWh/yr, Rheem ECEPH65 T2 RH350BM generates an estimated $163/yr electric bill at 18.16 cents/kWh (ranging from $132/yr in Washington hydro tiers up to $425/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of Rheem ECEPH65 T2 RH350BM (3.5 UEF)?

Rheem ECEPH65 T2 RH350BM requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH65 T2 FD310BM.

### What hot-water delivery rating governs Rheem ECEPH65 T2 RH350BM?

Rated for 75 gal FHR (+3 gal vs. 72 gal median), Rheem ECEPH65 T2 RH350BM prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen Rheem ECEPH65 T2 RH350BM for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What alternative models sit closest to Rheem ECEPH65 T2 RH350BM in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD310BM (3.5 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Next Engineering Checks for Rheem Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH65 T2 FD310BM (3.5 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd310bm/)
- [Compare Ruud PRO H65 T2 RU310BM (3.5 UEF)→](https://gcsradheat.com/water-heaters/ruud/pro-h65-t2-ru310bm/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)