title: "Rheem PRO H50 T2 RH310BM (3.5 UEF, 45 gal)"
url: https://gcsradheat.com/water-heaters/rheem/pro-h50-t2-rh310bm/
description: "With PD 2408553 certification, Rheem PRO H50 T2 RH310BM (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.5 UEF rating across its 45-gallon nominal."
---

ENERGY STAR water heater model · PD 2408553

# Rheem PRO H50 T2 RH310BM Water Heater Specifications (3.5 UEF)

With PD 2408553 certification, Rheem PRO H50 T2 RH310BM (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.5 UEF rating across its 45-gallon nominal tank, 67 gal First Hour Rating, standing #481 of 706 across 706 peers with Pass: +1.20 / +52.2% for May 6, 2029. Rated annual electricity draw of 915 kWh/yr equates to roughly $166/yr ($1,662 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH50 T2 FD310BM (3.5 UEF).

- **Uniform Energy Factor**: 3.5 UEF

- **Cohort UEF Rank**: #481 of 706

- **First Hour Rating**: 67 gal

- **Storage Volume**: 45 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.20 / +52.2%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem PRO H50 T2 RH310BM relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places Rheem PRO H50 T2 RH310BM at 3.5 UEF (#481 of 706; -0.20 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.

May 6, 2029 readiness: Rheem PRO H50 T2 RH310BM stands +1.20 UEF (+52.2%) relative to 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 915 kWh/yr for Rheem PRO H50 T2 RH310BM runs ~$166/yr vs. ~$632/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem PRO H50 T2 RH310BM: 10-year operating spend spans $1,339 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,317 in Hawaii (Highest EIA State) (47.18 cents/kWh).

In the Hybrid/Electric Heat Pump tier, Friedrich PROH50 T2 FD310BM (3.5 UEF, at parity) and Ruud PRO H50 T2 RU310BM (3.5 UEF, at parity) bracket Rheem PRO H50 T2 RH310BM.

## Which Specs Set Rheem PRO H50 T2 RH310BM Apart From Cohort Averages?

Ranked #481 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Rheem PRO H50 T2 RH310BM is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 2408553 |
| Model Number | PRO H50 T2 RH310BM | Draw pattern: Medium-Usage | PRO H50 T2 RH310BM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 67 gal | -5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 915 kWh/yr | -157 kWh/yr vs. 1,072 kWh/yr median | Est. $166/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 400% | -29.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 61.8" H x 22.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |

## How Do Regional kWh Prices Impact PRO H50 T2 RH310BM Over 10 Years?

Using EIA Table 5.6.A benchmarks, Rheem PRO H50 T2 RH310BM's 915 kWh/yr draw translates to roughly $166/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $166/yr | $1,662 | $4,660 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $432/yr | $4,317 | $12,106 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $272/yr | $2,722 | $7,634 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $146/yr | $1,456 | $4,083 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $134/yr | $1,339 | $3,754 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (915 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should Rheem Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to Rheem; verify whether your PRO H50 T2 RH310BM production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH50 T2 FD310BM](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd310bm/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (at parity) | 915 |
| [Ruud PRO H50 T2 RU310BM](https://gcsradheat.com/water-heaters/ruud/pro-h50-t2-ru310bm/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (at parity) | 915 |
| [A. O. Smith HPACO-45 1**+AXST-50T 1**](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-50t-1/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (+0.02) | 923 |
| [American MHPCO-45 1**+MXST-50T 1**](https://gcsradheat.com/water-heaters/american/mhpco-45-1-mxst-50t-1/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.52 (+0.02) | 923 |
| [Friedrich PROH50 T2 FD310UM](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd310um/) | Hybrid/Electric Heat Pump | 45 gal | 67 gal | 3.5 (at parity) | 915 |

## Who Is Rheem PRO H50 T2 RH310BM Best For — and When Should You Pick Friedrich PROH50 T2 FD310BM?

Evaluate whether Rheem PRO H50 T2 RH310BM's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- Rheem PRO H50 T2 RH310BM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem PRO H50 T2 RH310BM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Rheem PRO H50 T2 RH310BM** Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH50 T2 FD310BM footprint.

## Frequently Asked Technical Questions: Rheem PRO H50 T2 RH310BM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Rheem PRO H50 T2 RH310BM (3.5 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Rheem PRO H50 T2 RH310BM records 3.5 UEF (Pass: +1.20 / +52.2%), placing #481 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does Rheem PRO H50 T2 RH310BM fit inside a tight hallway closet or low-headroom utility room?

Rheem PRO H50 T2 RH310BM requires room for its 61.8 in. vertical shell and 22.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.3" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern Rheem PRO H50 T2 RH310BM?

For Rheem PRO H50 T2 RH310BM, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for Rheem PRO H50 T2 RH310BM?

Using 915 kWh/yr, Rheem PRO H50 T2 RH310BM generates an estimated $166/yr electric bill at 18.16 cents/kWh (ranging from $134/yr in Washington hydro tiers up to $432/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of Rheem PRO H50 T2 RH310BM (3.5 UEF)?

Rheem PRO H50 T2 RH310BM requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH50 T2 FD310BM.

### What hot-water delivery rating governs Rheem PRO H50 T2 RH310BM?

Rated for 67 gal FHR (-5 gal vs. 72 gal median), Rheem PRO H50 T2 RH310BM prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen Rheem PRO H50 T2 RH310BM for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What alternative models sit closest to Rheem PRO H50 T2 RH310BM in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH50 T2 FD310BM (3.5 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Essential Pre-Install Guides for Rheem PRO H50 T2 RH310BM

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH50 T2 FD310BM (3.5 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh50-t2-fd310bm/)
- [Compare Ruud PRO H50 T2 RU310BM (3.5 UEF)→](https://gcsradheat.com/water-heaters/ruud/pro-h50-t2-ru310bm/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)