title: "Rheem PROPH40 T2 RH375-30 (3.83 UEF, 36 gal)"
url: https://gcsradheat.com/water-heaters/rheem/proph40-t2-rh375-30/
description: "The Rheem PROPH40 T2 RH375-30 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.83 UEF rating across its 36-gallon nominal tank, 60 gal First Hour."
---

ENERGY STAR water heater model · PD 2408925

# Rheem PROPH40 T2 RH375-30 Water Heater Specifications (3.83 UEF)

The Rheem PROPH40 T2 RH375-30 (Hybrid/Electric Heat Pump, Electric) achieves a certified 3.83 UEF rating across its 36-gallon nominal tank, 60 gal First Hour Rating, ranking #230 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 2408925). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +1.53 / +66.5%. Rated annual electricity draw of 859 kWh/yr equates to roughly $156/yr ($1,560 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

- **Uniform Energy Factor**: 3.83 UEF

- **Cohort UEF Rank**: #230 of 706 (top 37.8%)

- **First Hour Rating**: 60 gal

- **Storage Volume**: 36 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.53 / +66.5%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem PROPH40 T2 RH375-30 relative to the cohort median.

Efficiency comparison & rule summary

Rheem PROPH40 T2 RH375-30 (3.83 UEF) ranks #230 of 706 Hybrid/Electric Heat Pump models — 38-way tie; top 37.8%, more efficient than 62.2% of Hybrid/Electric Heat Pump models, +0.13 UEF above the 3.70 UEF median.

Federal 2029 margin for Rheem PROPH40 T2 RH375-30: +1.53 UEF (+66.5%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 859 kWh/yr for Rheem PROPH40 T2 RH375-30 runs ~$156/yr vs. ~$649/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem PROPH40 T2 RH375-30: 10-year operating spend spans $1,257 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,053 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Rheem PROPH40 T2 RH375-30 (3.83 UEF) compares closely with Friedrich PROH40 T2 FD400-30 (3.83 UEF, at parity) and Richmond 10CE40-HP5U30 (3.83 UEF, at parity).

## How Complete Are the Certified Metrics for Rheem PROPH40 T2 RH375-30?

Standing at #230 of 706 (top 37.8%) among 706 certified Hybrid/Electric Heat Pump heaters, Rheem PROPH40 T2 RH375-30 brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 2408925 |
| Model Number | PROPH40 T2 RH375-30 | Draw pattern: Medium-Usage | PROPH40 T2 RH375-30 |
| Uniform Energy Factor (UEF) | 3.83 | +0.13 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 60 gal | -12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 859 kWh/yr | -213 kWh/yr vs. 1,072 kWh/yr median | Est. $156/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 434% | +5.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |

## What Is the Projected Utility Bill for PROPH40 T2 RH375-30 by State?

At 859 kWh/yr, Rheem PROPH40 T2 RH375-30 averages about $156/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $156/yr | $1,560 | $4,934 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $405/yr | $4,053 | $12,819 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $256/yr | $2,556 | $8,083 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $137/yr | $1,367 | $4,323 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $126/yr | $1,257 | $3,975 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (859 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are Rheem Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for Rheem and confirm your serial tag before scheduling contractor service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which 5 Models Offer Similar Output to PROPH40 T2 RH375-30?

Ordered by minimal capacity and UEF spread relative to Rheem PROPH40 T2 RH375-30, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH40 T2 FD400-30](https://gcsradheat.com/water-heaters/friedrich/proh40-t2-fd400-30/) | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| [Richmond 10CE40-HP5U30](https://gcsradheat.com/water-heaters/richmond/10ce40-hp5u30/) | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| [Ruud CPROPH40 T2 CD375-30](https://gcsradheat.com/water-heaters/ruud/cproph40-t2-cd375-30/) | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| [A. O. Smith CAHP-40 2**](https://gcsradheat.com/water-heaters/a-o-smith/cahp-40-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (-0.23) | 902 |
| [Friedrich PROH40 T2 FD400-SO](https://gcsradheat.com/water-heaters/friedrich/proh40-t2-fd400-so/) | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |

## What Installation Caveats Apply Before Buying Rheem PROPH40 T2 RH375-30?

Even high-UEF units like Rheem PROPH40 T2 RH375-30 (3.83 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Rheem PROPH40 T2 RH375-30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem PROPH40 T2 RH375-30 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Rheem PROPH40 T2 RH375-30** Strong Fit — 3.83 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH40 T2 FD400-30 footprint.

## Practical Specs & Code Questions for Rheem PROPH40 T2 RH375-30

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Rheem PROPH40 T2 RH375-30 eligible for continued manufacture past May 6, 2029?

At 3.83 UEF, Rheem PROPH40 T2 RH375-30 achieves Pass: +1.53 / +66.5% for the 2029 DOE standard and stands #230 of 706 (top 37.8%) against Friedrich PROH40 T2 FD400-30 and Richmond 10CE40-HP5U30.

### How tall and wide is Rheem PROPH40 T2 RH375-30, and what service clearance is needed?

Physical dimensions for Rheem PROPH40 T2 RH375-30 are 62.3 in. height and 20.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d)); verify stair turns and drain pan width before delivery.

### Will Rheem PROPH40 T2 RH375-30 require upgrading household electrical panels or gas piping?

Rheem PROPH40 T2 RH375-30 draws 240V at 21A max (Requires 240V dedicated branch circuit; check panel capacity); check whether existing 10/2 AWG 30A copper wiring aligns with nameplate amps.

### Is Rheem PROPH40 T2 RH375-30 economical to operate at 18.16 cents/kWh US electric rates?

Expect roughly $156/yr ($1,560 over 10 years) to power Rheem PROPH40 T2 RH375-30 at 859 kWh/yr under the 18.16 cents/kWh US average (ranging from $126/yr in Washington hydro tiers up to $405/yr in Hawaii).

### Which installation bottlenecks limit Rheem PROPH40 T2 RH375-30?

If ambient room air stays below 40 °F year-round or closet volume falls under 450 cu ft, Rheem PROPH40 T2 RH375-30 drops into resistance mode more often.

### How does Rheem PROPH40 T2 RH375-30 handle simultaneous showers and laundry?

Delivering 60 gal in the first hour (-12 gal vs. 72 gal median), Rheem PROPH40 T2 RH375-30 combines 36 gal tank storage with rapid burner/element recovery.

### How long is the warranty on Rheem PROPH40 T2 RH375-30 and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### How do 2026 post-OBBBA rebates affect buying Rheem PROPH40 T2 RH375-30?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-30 (3.83 UEF).

## Installation, Serial & DOE 2029 Links for PROPH40 T2 RH375-30

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH40 T2 FD400-30 (3.83 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh40-t2-fd400-30/)
- [Compare Richmond 10CE40-HP5U30 (3.83 UEF)→](https://gcsradheat.com/water-heaters/richmond/10ce40-hp5u30/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)