---
title: "Rheem PROPH65 T2 RH375-15 (3.55 UEF, 59 gal)"
url: https://gcsradheat.com/water-heaters/rheem/proph65-t2-rh375-15/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem PROPH65 T2 RH375-15 achieves a certified 3.55 UEF rating across its 59-gallon nominal tank, 54."
---

ENERGY STAR water heater model · PD 2408937

# Rheem PROPH65 T2 RH375-15 Water Heater Specifications (3.55 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem PROPH65 T2 RH375-15 achieves a certified 3.55 UEF rating across its 59-gallon nominal tank, 54 gal First Hour Rating and ranks #414 of 706 in its 706-model cohort (PD 2408937), recording Pass: +1.05 / +42.0% under 2029 DOE rules. Rated annual electricity draw of 887 kWh/yr equates to roughly $161/yr ($1,611 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD400-15 (3.55 UEF).

- **Uniform Energy Factor**: 3.55 UEF

- **Cohort UEF Rank**: #414 of 706

- **First Hour Rating**: 54 gal

- **Storage Volume**: 59 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.05 / +42.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem PROPH65 T2 RH375-15 relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Rheem PROPH65 T2 RH375-15 logs 3.55 UEF and ranks #414 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Rheem PROPH65 T2 RH375-15 holds a +1.05 UEF (+42.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 887 kWh/yr for Rheem PROPH65 T2 RH375-15 runs ~$161/yr vs. ~$622/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem PROPH65 T2 RH375-15: 10-year operating spend spans $1,298 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,185 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Rheem PROPH65 T2 RH375-15 (3.55 UEF)? Check Friedrich PROH65 T2 FD400-15 (3.55 UEF, at parity) and Richmond 10CE65-HP5U15 (3.55 UEF, at parity).

## Where Does Rheem PROPH65 T2 RH375-15 Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Rheem PROPH65 T2 RH375-15 holds #414 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 2408937 |
| Model Number | PROPH65 T2 RH375-15 | Draw pattern: Medium-Usage | PROPH65 T2 RH375-15 |
| Uniform Energy Factor (UEF) | 3.55 | -0.15 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 54 gal | -18 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 887 kWh/yr | -185 kWh/yr vs. 1,072 kWh/yr median | Est. $161/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 407% | -22.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 12 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |

## How Much Electricity Does PROPH65 T2 RH375-15 Use in Different States?

Estimated at $161/yr nationally (887 kWh/yr), 10-year utility spending for Rheem PROPH65 T2 RH375-15 shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $161/yr | $1,611 | $4,605 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $418/yr | $4,185 | $11,965 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $264/yr | $2,639 | $7,545 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $141/yr | $1,411 | $4,035 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $130/yr | $1,298 | $3,710 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (887 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on Rheem Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning Rheem; always cross-reference affected serial prefixes before ordering components. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to PROPH65 T2 RH375-15?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Rheem PROPH65 T2 RH375-15's gallon capacity and 3.55 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH65 T2 FD400-15](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd400-15/) | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (at parity) | 887 |
| [Richmond 10CE65-HP5U15](https://gcsradheat.com/water-heaters/richmond/10ce65-hp5u15/) | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (at parity) | 887 |
| [Ruud PROUH65 T2 CD400-15](https://gcsradheat.com/water-heaters/ruud/prouh65-t2-cd400-15/) | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (at parity) | 887 |
| [A. O. Smith HPACO-45 1**+AXST-66 1**](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-66-1/) | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (+0.15) | 1,341 |
| [Richmond 10E65-HP515](https://gcsradheat.com/water-heaters/richmond/10e65-hp515/) | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (at parity) | 887 |

## Who Is Rheem PROPH65 T2 RH375-15 Best For — and When Should You Pick Friedrich PROH65 T2 FD400-15?

Evaluate whether Rheem PROPH65 T2 RH375-15's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- Rheem PROPH65 T2 RH375-15 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem PROPH65 T2 RH375-15 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Rheem PROPH65 T2 RH375-15** Strong Fit — 3.55 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH65 T2 FD400-15 footprint.

## Common Homeowner Questions for Rheem PROPH65 T2 RH375-15

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Rheem PROPH65 T2 RH375-15 (3.55 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Rheem PROPH65 T2 RH375-15 records 3.55 UEF (Pass: +1.05 / +42.0%), placing #414 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does Rheem PROPH65 T2 RH375-15 fit inside a tight hallway closet or low-headroom utility room?

Rheem PROPH65 T2 RH375-15 requires room for its 64.2 in. vertical shell and 24.3 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern Rheem PROPH65 T2 RH375-15?

For Rheem PROPH65 T2 RH375-15, plan a 240V circuit at 12A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for Rheem PROPH65 T2 RH375-15?

Using 887 kWh/yr, Rheem PROPH65 T2 RH375-15 generates an estimated $161/yr electric bill at 18.16 cents/kWh (ranging from $130/yr in Washington hydro tiers up to $418/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of Rheem PROPH65 T2 RH375-15 (3.55 UEF)?

Rheem PROPH65 T2 RH375-15 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH65 T2 FD400-15.

### What hot-water delivery rating governs Rheem PROPH65 T2 RH375-15?

Rated for 54 gal FHR (-18 gal vs. 72 gal median), Rheem PROPH65 T2 RH375-15 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen Rheem PROPH65 T2 RH375-15 for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What alternative models sit closest to Rheem PROPH65 T2 RH375-15 in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD400-15 (3.55 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Next Engineering Checks for Rheem Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH65 T2 FD400-15 (3.55 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd400-15/)
- [Compare Richmond 10CE65-HP5U15 (3.55 UEF)→](https://gcsradheat.com/water-heaters/richmond/10ce65-hp5u15/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)
