title: "Rheem PROUH65 T2 RH350UM (3.5 UEF, 59 gal)"
url: https://gcsradheat.com/water-heaters/rheem/prouh65-t2-rh350um/
description: "Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem PROUH65 T2 RH350UM achieves a certified 3.5 UEF rating across its 59-gallon nominal tank, 75 gal."
---

ENERGY STAR water heater model · PD 3994192

# Rheem PROUH65 T2 RH350UM Water Heater Specifications (3.5 UEF)

Engineered as a Electric Hybrid/Electric Heat Pump unit, Rheem PROUH65 T2 RH350UM achieves a certified 3.5 UEF rating across its 59-gallon nominal tank, 75 gal First Hour Rating and ranks #481 of 706 in its 706-model cohort (PD 3994192), recording Pass: +1.00 / +40.0% under 2029 DOE rules. Rated annual electricity draw of 900 kWh/yr equates to roughly $163/yr ($1,634 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH65 T2 FD310BM (3.5 UEF).

- **Uniform Energy Factor**: 3.5 UEF

- **Cohort UEF Rank**: #481 of 706

- **First Hour Rating**: 75 gal

- **Storage Volume**: 59 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.00 / +40.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem PROUH65 T2 RH350UM relative to the cohort median.

Efficiency comparison & rule summary

Within the 706-unit Hybrid/Electric Heat Pump cohort, Rheem PROUH65 T2 RH350UM logs 3.5 UEF and ranks #481 of 706.

Against 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF), Rheem PROUH65 T2 RH350UM holds a +1.00 UEF (+40.0%) compliance cushion. At EIA August 2026 national rates (18.16 cents/kWh), 900 kWh/yr for Rheem PROUH65 T2 RH350UM runs ~$163/yr vs. ~$622/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem PROUH65 T2 RH350UM: 10-year operating spend spans $1,317 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,246 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Cross-shopping Rheem PROUH65 T2 RH350UM (3.5 UEF)? Check Friedrich PROH65 T2 FD310BM (3.5 UEF, at parity) and Ruud PRO H65 T2 RU310BM (3.5 UEF, at parity).

## Where Does Rheem PROUH65 T2 RH350UM Rank Against Peer Hybrid/Electric Heat Pump Units?

Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Rheem PROUH65 T2 RH350UM holds #481 of 706; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 3994192 |
| Model Number | PROUH65 T2 RH350UM | Draw pattern: High-Usage | PROUH65 T2 RH350UM |
| Uniform Energy Factor (UEF) | 3.5 | -0.20 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 75 gal | +3 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 900 kWh/yr | -172 kWh/yr vs. 1,072 kWh/yr median | Est. $163/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 409% | -20.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 64.2" H x 24.3" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |

## How Much Electricity Does PROUH65 T2 RH350UM Use in Different States?

Estimated at $163/yr nationally (900 kWh/yr), 10-year utility spending for Rheem PROUH65 T2 RH350UM shifts sharply between low-rate hydro and coastal grids.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $163/yr | $1,634 | $4,584 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $425/yr | $4,246 | $11,908 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $268/yr | $2,678 | $7,509 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $143/yr | $1,432 | $4,016 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $132/yr | $1,317 | $3,693 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (900 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on Rheem Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning Rheem; always cross-reference affected serial prefixes before ordering components. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which Competing Hybrid/Electric Heat Pump Models Compare Closest to PROUH65 T2 RH350UM?

Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Rheem PROUH65 T2 RH350UM's gallon capacity and 3.5 UEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH65 T2 FD310BM](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd310bm/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (at parity) | 900 |
| [Ruud PRO H65 T2 RU310BM](https://gcsradheat.com/water-heaters/ruud/pro-h65-t2-ru310bm/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (at parity) | 900 |
| [Richmond 10CE65-HP5U15](https://gcsradheat.com/water-heaters/richmond/10ce65-hp5u15/) | Hybrid/Electric Heat Pump | 59 gal | 54 gal | 3.55 (+0.05) | 887 |
| [A. O. Smith HPACO-45 1**+AXST-66 1**](https://gcsradheat.com/water-heaters/a-o-smith/hpaco-45-1-axst-66-1/) | Hybrid/Electric Heat Pump | 60 gal | 82 gal | 3.7 (+0.20) | 1,341 |
| [Friedrich PROH65 T2 FD310UM](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd310um/) | Hybrid/Electric Heat Pump | 59 gal | 75 gal | 3.5 (at parity) | 900 |

## Which Home Setups Are NOT a Fit for Rheem PROUH65 T2 RH350UM?

Comparing Rheem PROUH65 T2 RH350UM against Friedrich PROH65 T2 FD310BM requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- Rheem PROUH65 T2 RH350UM needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem PROUH65 T2 RH350UM directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Rheem PROUH65 T2 RH350UM** Strong Fit — 3.5 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH65 T2 FD310BM footprint.

## Common Homeowner Questions for Rheem PROUH65 T2 RH350UM

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Rheem PROUH65 T2 RH350UM score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Rheem PROUH65 T2 RH350UM logs 3.5 UEF (Pass: +1.00 / +40.0%) within the 706-unit Hybrid/Electric Heat Pump group.

### What physical clearance dimensions apply when installing Rheem PROUH65 T2 RH350UM?

With a 64.2 in. height and 24.3 in. diameter, Rheem PROUH65 T2 RH350UM fits spaces matching: verify 72 in. vertical headroom; clears 28 in. utility doorway (24.3" d), plus 6–12 in. above for plumbing shutoffs.

### What 240V circuit or IFGC fuel line capacity fits Rheem PROUH65 T2 RH350UM?

Powered via 240V at 21A max, Rheem PROUH65 T2 RH350UM requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

### How do state electricity prices change annual costs for Rheem PROUH65 T2 RH350UM?

Annual electric spend for Rheem PROUH65 T2 RH350UM (900 kWh/yr) averages $163/yr nationwide (ranging from $132/yr in Washington hydro tiers up to $425/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

### What homeowner setups should avoid choosing Rheem PROUH65 T2 RH350UM?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Rheem PROUH65 T2 RH350UM.

### Is Rheem PROUH65 T2 RH350UM sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Rheem PROUH65 T2 RH350UM at 75 gal First Hour Rating (+3 gal vs. 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

### Does Rheem have active CPSC SaferProducts notices affecting PROUH65 T2 RH350UM?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### Which competing water heater matches Rheem PROUH65 T2 RH350UM (3.5 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Rheem PROUH65 T2 RH350UM. Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH65 T2 FD310BM (3.5 UEF).

## Next Engineering Checks for Rheem Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH65 T2 FD310BM (3.5 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh65-t2-fd310bm/)
- [Compare Ruud PRO H65 T2 RU310BM (3.5 UEF)→](https://gcsradheat.com/water-heaters/ruud/pro-h65-t2-ru310bm/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)