title: "Rheem RECTGH-SR11IP (0.96 UEF, Gas Tankless)"
url: https://gcsradheat.com/water-heaters/rheem/rectgh-sr11ip/
description: "Engineered as a Propane Gas Tankless unit, Rheem RECTGH-SR11IP achieves a certified 0.96 UEF rating and ranks #39 of 464 in its 464-model cohort (PD 3462962)."
---

ENERGY STAR water heater model · PD 3462962

# Rheem RECTGH-SR11IP Water Heater Specifications (0.96 UEF)

Engineered as a Propane Gas Tankless unit, Rheem RECTGH-SR11IP achieves a certified 0.96 UEF rating and ranks #39 of 464 in its 464-model cohort (PD 3462962), recording Pass: +0.05 / +5.5% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is Bradford White RTGR199N1** (0.96 UEF).

- **Uniform Energy Factor**: 0.96 UEF

- **Cohort UEF Rank**: #39 of 464 (top 34.1%)

- **First Hour Rating**: On-Demand

- **Storage Volume**: Tankless

- **Fuel / Type**: Propane / Gas Tankless

- **DOE 2029 Rule Status**: Pass: +0.05 / +5.5%

Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils

Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Rheem RECTGH-SR11IP relative to the cohort median.

Efficiency comparison & rule summary

Within the 464-unit Gas Tankless cohort, Rheem RECTGH-SR11IP logs 0.96 UEF and ranks #39 of 464.

Rheem RECTGH-SR11IP delivers +0.05 UEF (+5.5%) margin above the 0.91 UEF Propane tankless mandate; thermal recovery tests at 98% (At 98.0% median).

Cross-shopping Rheem RECTGH-SR11IP (0.96 UEF)? Check Bradford White RTGR199N1** (0.96 UEF, at parity) and Friedrich FDTGH-S10I (0.96 UEF, at parity).

## Which Specs Set Rheem RECTGH-SR11IP Apart From Cohort Averages?

Ranked #39 of 464 (top 34.1%) inside the 464-model Gas Tankless cohort, Rheem RECTGH-SR11IP is evaluated row by row below against category medians.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 3462962 |
| Model Number | RECTGH-SR11IP | Draw pattern: High-Usage | RECTGH-SR11IP |
| Uniform Energy Factor (UEF) | 0.96 | +0.01 UEF vs. 0.95 UEF median | 10 CFR 430 Test Method |
| Thermal Recovery Efficiency | 98% | At 98.0% median | ENERGY STAR Dataset |
| Electrical Circuit Requirements | 2 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2024-04-26 | Certified 2024-04-26 | Markets: United States |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should Rheem Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to Rheem; verify whether your RECTGH-SR11IP production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## How Do Five Nearby Gas Tankless Models Stack Up?

Five alternative Gas Tankless units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Bradford White RTGR199N1**](https://gcsradheat.com/water-heaters/bradford-white/rtgr199n1/) | Gas Tankless | — | — | 0.96 (at parity) | — |
| [Friedrich FDTGH-S10I](https://gcsradheat.com/water-heaters/friedrich/fdtgh-s10i/) | Gas Tankless | — | — | 0.96 (at parity) | — |
| [Kepler JSG48-29PCH/180K](https://gcsradheat.com/water-heaters/kepler/jsg48-29pch-180k/) | Gas Tankless | — | — | 0.96 (at parity) | — |
| [Kings Peak KNG199ICW](https://gcsradheat.com/water-heaters/kings-peak/kng199icw/) | Gas Tankless | — | — | 0.96 (at parity) | — |
| [Bradford White RTGR199X1**](https://gcsradheat.com/water-heaters/bradford-white/rtgr199x1/) | Gas Tankless | — | — | 0.96 (at parity) | — |

## What Installation Caveats Apply Before Buying Rheem RECTGH-SR11IP?

Even high-UEF units like Rheem RECTGH-SR11IP (0.96 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

### Key Limitations & Exclusions

- Converting a 40K tank to Rheem RECTGH-SR11IP often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
- Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Rheem RECTGH-SR11IP's heat exchanger.
- Condensing Rheem RECTGH-SR11IP requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

### Which Option Fits Your Situation?

**Existing 3/4 in.+ Gas Line + Marathon Hot Draws** Strong Fit — Rheem RECTGH-SR11IP delivers continuous 0.96 UEF performance.

**Softened/Low-Scale Water (<7.0 GPG)** Strong Fit — Minimal calcium scale between 12-month flushes.

**Long 1/2 in. Gas Run (>10 ft)** Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

## Frequently Asked Technical Questions: Rheem RECTGH-SR11IP

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Is Rheem RECTGH-SR11IP eligible for continued manufacture past May 6, 2029?

At 0.96 UEF, Rheem RECTGH-SR11IP achieves Pass: +0.05 / +5.5% for the 2029 DOE standard and stands #39 of 464 (top 34.1%) against Bradford White RTGR199N1** and Friedrich FDTGH-S10I.

### How tall and wide is Rheem RECTGH-SR11IP, and what service clearance is needed?

Rheem RECTGH-SR11IP saves floor space via its gas tankless layout (wall-hung / compact envelope); inspect service-valve swing clearance below the bottom manifold.

### Will Rheem RECTGH-SR11IP require upgrading household electrical panels or gas piping?

Check Propane piping and venting for Rheem RECTGH-SR11IP (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.

### Is Rheem RECTGH-SR11IP economical to operate at 18.16 cents/kWh US electric rates?

Fuel bills for Rheem RECTGH-SR11IP (Propane, 0.96 UEF) hinge on household gallon demand and local gas utility tariffs compared with Bradford White RTGR199N1**.

### Which installation bottlenecks limit Rheem RECTGH-SR11IP?

Without 3/4 in.–1 in. IFGC gas sizing and Category IV PVC exhaust routing, Rheem RECTGH-SR11IP requires added mechanical rework over standard tank replacements.

### How does Rheem RECTGH-SR11IP handle simultaneous showers and laundry?

Rheem RECTGH-SR11IP supplies endless hot water within its maximum BTU/flow curve—check cold-climate winter groundwater temperatures before running 3+ fixtures at once.

### How long is the warranty on Rheem RECTGH-SR11IP and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### How do 2026 post-OBBBA rebates affect buying Rheem RECTGH-SR11IP?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Gas Tankless is Bradford White RTGR199N1** (0.96 UEF).

## Essential Pre-Install Guides for Rheem RECTGH-SR11IP

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Bradford White RTGR199N1** (0.96 UEF)→](https://gcsradheat.com/water-heaters/bradford-white/rtgr199n1/)
- [Compare Friedrich FDTGH-S10I (0.96 UEF)→](https://gcsradheat.com/water-heaters/friedrich/fdtgh-s10i/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)