title: "Rheem RS120-64BP-TG (9.9 SUEF, 120 gal)"
url: https://gcsradheat.com/water-heaters/rheem/rs120-64bp-tg/
description: "In the 25-unit Solar with Gas Backup class, Rheem RS120-64BP-TG (Natural Gas) achieves a certified 9.9 SUEF rating across its 120-gallon nominal tank (rank #17."
---

ENERGY STAR water heater model · PD 2409764

# Rheem RS120-64BP-TG Water Heater Specifications (9.9 SUEF)

In the 25-unit Solar with Gas Backup class, Rheem RS120-64BP-TG (Natural Gas) achieves a certified 9.9 SUEF rating across its 120-gallon nominal tank (rank #17 of 25, PD 2409764) and verifies as Exempt — Solar SUEF for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is AET B-DBS-G2-80-64 (1.9 SUEF).

- **Solar UEF (SUEF)**: 9.9 SUEF

- **Cohort SUEF Rank**: #17 of 25

- **First Hour Rating**: On-Demand

- **Storage Volume**: 120 gal

- **Fuel / Type**: Natural Gas / Solar with Gas Backup

- **DOE 2029 Rule Status**: Exempt — Solar SUEF

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Solar with Gas Backup SUEF Efficiency Distribution (25 Certified Units). Highlighted pin shows Rheem RS120-64BP-TG relative to the cohort median.

Efficiency comparison & rule summary

Rheem RS120-64BP-TG records 9.9 SUEF efficiency, putting it #17 of 25 among 25 Solar with Gas Backup peers.

Solar collector & storage profile, OG-300 #2010048C for Rheem RS120-64BP-TG: Indirect Forced Circulation architecture; 65.7 sq ft Flat Plate collector; 120 gal storage tank; freeze limit -30 deg F.

Competing options beside Rheem RS120-64BP-TG (9.9 SUEF) are AET B-DBS-G2-80-64 (1.9 SUEF, delta -8.00) and Heliodyne HPAK 1 408 GT 80 ACD Z (99.0 SUEF, delta +89.10).

## Where Does Rheem RS120-64BP-TG Rank Against Peer Solar with Gas Backup Units?

Audited against 25 ENERGY STAR Solar with Gas Backup listings, Rheem RS120-64BP-TG holds #17 of 25; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 25 ENERGY STAR Solar with Gas Backup peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 2409764 |
| Model Number | RS120-64BP-TG | Draw pattern: High-Usage | RS120-64BP-TG |
| Solar Uniform Energy Factor (SUEF) | 9.9 | -74.60 SUEF vs. 84.50 SUEF median | 10 CFR 430 Test Method |
| Solar System & Collector | Indirect Forced Circulation (Flat Plate) | 65.7 sq ft aperture | OG-300 #2010048C |
| Collector Freeze Tolerance | -30 °F | SRCC freeze protection rating | ENERGY STAR Solar Dataset |
| Certification Date | 2020-11-13 | Certified 2020-11-13 | Markets: United States |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Does CPSC Flag Any Safety Notices on Rheem Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning Rheem; always cross-reference affected serial prefixes before ordering components. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which Competing Solar with Gas Backup Models Compare Closest to RS120-64BP-TG?

Compare five nearby ENERGY STAR Solar with Gas Backup options matched closely to Rheem RS120-64BP-TG's gallon capacity and 9.9 SUEF efficiency.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | SUEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [AET B-DBS-G2-80-64](https://gcsradheat.com/water-heaters/aet/b-dbs-g2-80-64/) | Solar with Gas Backup | 80 gal | — | 1.9 (-8.00) | — |
| [Heliodyne HPAK 1 408 GT 80 ACD Z](https://gcsradheat.com/water-heaters/heliodyne/hpak-1-408-gt-80-acd-z/) | Solar with Gas Backup | 80 gal | — | 99.0 (+89.10) | — |
| [Solahart ASTG 302J](https://gcsradheat.com/water-heaters/solahart/astg-302j/) | Solar with Gas Backup | 80 gal | — | 84.5 (+74.60) | — |
| [SAMMLER A308](https://gcsradheat.com/water-heaters/sammler/a308/) | Solar with Gas Backup | 79 gal | — | 99.0 (+89.10) | — |
| [Heliodyne HPAK 1 410 GT 120 ACD Z](https://gcsradheat.com/water-heaters/heliodyne/hpak-1-410-gt-120-acd-z/) | Solar with Gas Backup | 80 gal | — | 99.0 (+89.10) | — |

## What Are the Limitations of Rheem RS120-64BP-TG and Who Should Not Install It?

Before ordering Rheem RS120-64BP-TG (Solar with Gas Backup, 9.9 SUEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

### Key Limitations & Exclusions

- Rheem RS120-64BP-TG logs 9.9 SUEF (Exempt — Solar SUEF); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect Rheem RS120-64BP-TG's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 120 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for Rheem RS120-64BP-TG** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like AET B-DBS-G2-80-64.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Common Homeowner Questions for Rheem RS120-64BP-TG

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### Does Rheem RS120-64BP-TG pass the May 6, 2029 federal DOE efficiency rule?

Rheem RS120-64BP-TG is a solar thermal collector system rated at 9.9 SUEF. Solar thermal assemblies remain outside residential electric storage and gas tankless UEF floors under 10 CFR 430.32.

### What doorway width and ceiling height does Rheem RS120-64BP-TG need?

Rheem RS120-64BP-TG mounts as a solar with gas backup without a bulky floor tank (wall-hung / compact envelope). Verify vent termination distances and combustion air clearances per IPC or UPC.

### What gas pipe size or electrical breaker does Rheem RS120-64BP-TG require?

Rheem RS120-64BP-TG runs on Natural Gas (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

### How much electricity or energy does Rheem RS120-64BP-TG cost per year to run?

ENERGY STAR rates Rheem RS120-64BP-TG as a Natural Gas heater (9.9 SUEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Solar with Gas Backup draw.

### Who should NOT install Rheem RS120-64BP-TG, and what are its limits?

Rheem RS120-64BP-TG (9.9 SUEF) is not suited for multi-bath marathon draws exceeding its 120 gal capacity or buyers prioritizing May 6, 2029 high-UEF HPWH rebates.

### How many bathrooms or people can Rheem RS120-64BP-TG serve at peak demand?

Rheem RS120-64BP-TG provides continuous Solar with Gas Backup delivery rather than a fixed storage FHR; size GPM flow against winter incoming groundwater temperature and 2.0 GPM showers.

### Are there CPSC safety recalls or serial checks for Rheem RS120-64BP-TG?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What 2026 rebates apply to Rheem RS120-64BP-TG, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Solar with Gas Backup is AET B-DBS-G2-80-64 (1.9 SUEF).

## Next Engineering Checks for Rheem Owners

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare AET B-DBS-G2-80-64 (1.9 SUEF)→](https://gcsradheat.com/water-heaters/aet/b-dbs-g2-80-64/)
- [Compare Heliodyne HPAK 1 408 GT 80 ACD Z (99.0 SUEF)→](https://gcsradheat.com/water-heaters/heliodyne/hpak-1-408-gt-80-acd-z/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)