title: "Rheem RS80-40BP-TG (8 SUEF, 80 gal)"
url: https://gcsradheat.com/water-heaters/rheem/rs80-40bp-tg/
description: "Engineered as a Natural Gas Solar with Gas Backup unit, Rheem RS80-40BP-TG achieves a certified 8.0 SUEF rating across its 80-gallon nominal tank and ranks #18."
---

ENERGY STAR water heater model · PD 2409762

# Rheem RS80-40BP-TG Water Heater Specifications (8 SUEF)

Engineered as a Natural Gas Solar with Gas Backup unit, Rheem RS80-40BP-TG achieves a certified 8.0 SUEF rating across its 80-gallon nominal tank and ranks #18 of 25 in its 25-model cohort (PD 2409762), recording Exempt — Solar SUEF under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is AET B-DBS-G2-80-64 (1.9 SUEF).

- **Solar UEF (SUEF)**: 8.0 SUEF

- **Cohort SUEF Rank**: #18 of 25

- **First Hour Rating**: On-Demand

- **Storage Volume**: 80 gal

- **Fuel / Type**: Natural Gas / Solar with Gas Backup

- **DOE 2029 Rule Status**: Exempt — Solar SUEF

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Solar with Gas Backup SUEF Efficiency Distribution (25 Certified Units). Highlighted pin shows Rheem RS80-40BP-TG relative to the cohort median.

Efficiency comparison & rule summary

Within the 25-unit Solar with Gas Backup cohort, Rheem RS80-40BP-TG logs 8.0 SUEF and ranks #18 of 25.

Solar collector & storage profile, OG-300 #2010048A for Rheem RS80-40BP-TG: Indirect Forced Circulation architecture; 24.7 sq ft Flat Plate collector; 80 gal storage tank; freeze limit -30 deg F.

Cross-shopping Rheem RS80-40BP-TG (8.0 SUEF)? Check AET B-DBS-G2-80-64 (1.9 SUEF, delta -6.10) and Heliodyne HPAK 1 408 GT 80 ACD Z (99.0 SUEF, delta +91.00).

## Which Specs Set Rheem RS80-40BP-TG Apart From Cohort Averages?

Ranked #18 of 25 inside the 25-model Solar with Gas Backup cohort, Rheem RS80-40BP-TG is evaluated row by row below against category medians.

Certified model attributes compared against 25 ENERGY STAR Solar with Gas Backup peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 2409762 |
| Model Number | RS80-40BP-TG | Draw pattern: Low-Usage | RS80-40BP-TG |
| Solar Uniform Energy Factor (SUEF) | 8.0 | -76.50 SUEF vs. 84.50 SUEF median | 10 CFR 430 Test Method |
| Solar System & Collector | Indirect Forced Circulation (Flat Plate) | 24.7 sq ft aperture | OG-300 #2010048A |
| Collector Freeze Tolerance | -30 °F | SRCC freeze protection rating | ENERGY STAR Solar Dataset |
| Certification Date | 2020-11-13 | Certified 2020-11-13 | Markets: United States |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should Rheem Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to Rheem; verify whether your RS80-40BP-TG production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## How Do Five Nearby Solar with Gas Backup Models Stack Up?

Five alternative Solar with Gas Backup units with nearly identical gallon storage and SUEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | SUEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [AET B-DBS-G2-80-64](https://gcsradheat.com/water-heaters/aet/b-dbs-g2-80-64/) | Solar with Gas Backup | 80 gal | — | 1.9 (-6.10) | — |
| [Heliodyne HPAK 1 408 GT 80 ACD Z](https://gcsradheat.com/water-heaters/heliodyne/hpak-1-408-gt-80-acd-z/) | Solar with Gas Backup | 80 gal | — | 99.0 (+91.00) | — |
| [Solahart ASTG 302J](https://gcsradheat.com/water-heaters/solahart/astg-302j/) | Solar with Gas Backup | 80 gal | — | 84.5 (+76.50) | — |
| [SAMMLER A308](https://gcsradheat.com/water-heaters/sammler/a308/) | Solar with Gas Backup | 79 gal | — | 99.0 (+91.00) | — |
| [Heliodyne HPAK 1 410 GT 120 ACD Z](https://gcsradheat.com/water-heaters/heliodyne/hpak-1-410-gt-120-acd-z/) | Solar with Gas Backup | 80 gal | — | 99.0 (+91.00) | — |

## Which Home Setups Are NOT a Fit for Rheem RS80-40BP-TG?

Comparing Rheem RS80-40BP-TG against AET B-DBS-G2-80-64 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- Rheem RS80-40BP-TG logs 8.0 SUEF (Exempt — Solar SUEF); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect Rheem RS80-40BP-TG's sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 80 gal will deplete stored recovery capacity.

### Which Option Fits Your Situation?

**Direct Footprint Replacement for Rheem RS80-40BP-TG** Strong Fit — Matches existing plumbing and vent clearances.

**2026 Post-OBBBA Rebate Buyers** Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like AET B-DBS-G2-80-64.

**Very Hard Well Water (>10.5 GPG)** Add Softener / Flush — Schedule 6-month tank sediment drains.

## Frequently Asked Technical Questions: Rheem RS80-40BP-TG

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Rheem RS80-40BP-TG score under 10 CFR 430.32 May 2029 water heater minimums?

Under 10 CFR 430.32, solar models like Rheem RS80-40BP-TG (8.0 SUEF) are evaluated by Solar Uniform Energy Factor rather than standard electric or gas tank thresholds.

### What physical clearance dimensions apply when installing Rheem RS80-40BP-TG?

Because Rheem RS80-40BP-TG is a solar with gas backup unit (wall-hung / compact envelope), check wall-stud backing, condensate neutralizer routing, and outdoor vent clearances first.

### What 240V circuit or IFGC fuel line capacity fits Rheem RS80-40BP-TG?

Rheem RS80-40BP-TG utilizes Natural Gas combustion (120V AC ignition/fan + gas piping check). Confirm static/dynamic manifold pressure and 120V GFCI outlet availability before swapping out an older storage tank.

### How do state electricity prices change annual costs for Rheem RS80-40BP-TG?

Rheem RS80-40BP-TG operates on Natural Gas (8.0 SUEF); check regional therm costs and hot-water recirculation schedules since tankless standby electricity stays minimal.

### What homeowner setups should avoid choosing Rheem RS80-40BP-TG?

Homes with >10.5 GPG Very Hard well water without regular 6-month sediment draining will shorten the tank life of Rheem RS80-40BP-TG (Exempt — Solar SUEF).

### Is Rheem RS80-40BP-TG sized adequately for a 2-to-4-person household?

Instead of First Hour Rating, Rheem RS80-40BP-TG heats water continuously; two concurrent 2.0 GPM showers and a faucet require ~5.5 GPM at a 70 °F temperature rise.

### Does Rheem have active CPSC SaferProducts notices affecting RS80-40BP-TG?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### Which competing water heater matches Rheem RS80-40BP-TG (8.0 SUEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Rheem RS80-40BP-TG. Closest peer in Solar with Gas Backup is AET B-DBS-G2-80-64 (1.9 SUEF).

## Essential Pre-Install Guides for Rheem RS80-40BP-TG

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare AET B-DBS-G2-80-64 (1.9 SUEF)→](https://gcsradheat.com/water-heaters/aet/b-dbs-g2-80-64/)
- [Compare Heliodyne HPAK 1 408 GT 80 ACD Z (99.0 SUEF)→](https://gcsradheat.com/water-heaters/heliodyne/hpak-1-408-gt-80-acd-z/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)