title: "Rheem RTGH-S11I (0.96 UEF, Gas Tankless)"
url: https://gcsradheat.com/water-heaters/rheem/rtgh-s11i/
description: "With PD 3462908 certification, Rheem RTGH-S11I (Gas Tankless, Natural Gas, Propane) achieves a certified 0.96 UEF rating, standing #39 of 464 across 464 peers."
---

ENERGY STAR water heater model · PD 3462908

# Rheem RTGH-S11I Water Heater Specifications (0.96 UEF)

With PD 3462908 certification, Rheem RTGH-S11I (Gas Tankless, Natural Gas, Propane) achieves a certified 0.96 UEF rating, standing #39 of 464 across 464 peers with Pass: +0.05 / +5.5% for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is Bradford White RTGR199N1** (0.96 UEF).

- **Uniform Energy Factor**: 0.96 UEF

- **Cohort UEF Rank**: #39 of 464 (top 34.1%)

- **First Hour Rating**: On-Demand

- **Storage Volume**: Tankless

- **Fuel / Type**: Natural Gas, Propane / Gas Tankless

- **DOE 2029 Rule Status**: Pass: +0.05 / +5.5%

Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils

Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Rheem RTGH-S11I relative to the cohort median.

Efficiency comparison & rule summary

ENERGY STAR certification places Rheem RTGH-S11I at 0.96 UEF (#39 of 464; +0.01 UEF vs. 0.95 UEF median) in Gas Tankless.

With Natural Gas, Propane condensing combustion, Rheem RTGH-S11I stands +0.05 UEF (+5.5%) above the 2029 0.91 UEF minimum; thermal recovery tests at 98% (At 98.0% median).

In the Gas Tankless tier, Bradford White RTGR199N1** (0.96 UEF, at parity) and Friedrich FDTGH-S10I (0.96 UEF, at parity) bracket Rheem RTGH-S11I.

## How Complete Are the Certified Metrics for Rheem RTGH-S11I?

Standing at #39 of 464 (top 34.1%) among 464 certified Gas Tankless heaters, Rheem RTGH-S11I brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 3462908 |
| Model Number | RTGH-S11I | Draw pattern: High-Usage | RTGH-S11I |
| Uniform Energy Factor (UEF) | 0.96 | +0.01 UEF vs. 0.95 UEF median | 10 CFR 430 Test Method |
| Thermal Recovery Efficiency | 98% | At 98.0% median | ENERGY STAR Dataset |
| Electrical Circuit Requirements | 2 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2024-04-26 | Certified 2024-04-26 | Markets: United States |

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are Rheem Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for Rheem and confirm your serial tag before scheduling contractor service. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which 5 Models Offer Similar Output to RTGH-S11I?

Ordered by minimal capacity and UEF spread relative to Rheem RTGH-S11I, these five certified peers give direct replacement benchmarks.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Bradford White RTGR199N1**](https://gcsradheat.com/water-heaters/bradford-white/rtgr199n1/) | Gas Tankless | — | — | 0.96 (at parity) | — |
| [Friedrich FDTGH-S10I](https://gcsradheat.com/water-heaters/friedrich/fdtgh-s10i/) | Gas Tankless | — | — | 0.96 (at parity) | — |
| [Kepler JSG48-29PCH/180K](https://gcsradheat.com/water-heaters/kepler/jsg48-29pch-180k/) | Gas Tankless | — | — | 0.96 (at parity) | — |
| [Kings Peak KNG199ICW](https://gcsradheat.com/water-heaters/kings-peak/kng199icw/) | Gas Tankless | — | — | 0.96 (at parity) | — |
| [Bradford White RTGR199X1**](https://gcsradheat.com/water-heaters/bradford-white/rtgr199x1/) | Gas Tankless | — | — | 0.96 (at parity) | — |

## Which Home Setups Are NOT a Fit for Rheem RTGH-S11I?

Comparing Rheem RTGH-S11I against Bradford White RTGR199N1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

### Key Limitations & Exclusions

- Converting a 40K tank to Rheem RTGH-S11I often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
- Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Rheem RTGH-S11I's heat exchanger.
- Condensing Rheem RTGH-S11I requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

### Which Option Fits Your Situation?

**Existing 3/4 in.+ Gas Line + Marathon Hot Draws** Strong Fit — Rheem RTGH-S11I delivers continuous 0.96 UEF performance.

**Softened/Low-Scale Water (<7.0 GPG)** Strong Fit — Minimal calcium scale between 12-month flushes.

**Long 1/2 in. Gas Run (>10 ft)** Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

## Practical Specs & Code Questions for Rheem RTGH-S11I

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Rheem RTGH-S11I score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Rheem RTGH-S11I logs 0.96 UEF (Pass: +0.05 / +5.5%) within the 464-unit Gas Tankless group.

### What physical clearance dimensions apply when installing Rheem RTGH-S11I?

Because Rheem RTGH-S11I is a gas tankless unit (wall-hung / compact envelope), check wall-stud backing, condensate neutralizer routing, and outdoor vent clearances first.

### What 240V circuit or IFGC fuel line capacity fits Rheem RTGH-S11I?

Rheem RTGH-S11I utilizes Natural Gas, Propane combustion (120V AC ignition/fan + gas piping check). Confirm static/dynamic manifold pressure and 120V GFCI outlet availability before swapping out an older storage tank.

### How do state electricity prices change annual costs for Rheem RTGH-S11I?

Rheem RTGH-S11I operates on Natural Gas, Propane (0.96 UEF); check regional therm costs and hot-water recirculation schedules since tankless standby electricity stays minimal.

### What homeowner setups should avoid choosing Rheem RTGH-S11I?

Northern homes with 40–45 °F winter groundwater see reduced simultaneous GPM output from Rheem RTGH-S11I, while hard water >7.0 GPG demands annual vinegar flushing.

### Is Rheem RTGH-S11I sized adequately for a 2-to-4-person household?

Instead of First Hour Rating, Rheem RTGH-S11I heats water continuously; two concurrent 2.0 GPM showers and a faucet require ~5.5 GPM at a 70 °F temperature rise.

### Does Rheem have active CPSC SaferProducts notices affecting RTGH-S11I?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### Which competing water heater matches Rheem RTGH-S11I (0.96 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Rheem RTGH-S11I. Closest peer in Gas Tankless is Bradford White RTGR199N1** (0.96 UEF).

## Installation, Serial & DOE 2029 Links for RTGH-S11I

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Bradford White RTGR199N1** (0.96 UEF)→](https://gcsradheat.com/water-heaters/bradford-white/rtgr199n1/)
- [Compare Friedrich FDTGH-S10I (0.96 UEF)→](https://gcsradheat.com/water-heaters/friedrich/fdtgh-s10i/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm gas pipe length and CFH capacity (especially 199,000 BTU/h condensing tankless conversions under IFGC Table 402.4) and decode the old unit's serial plate.
[Verify Gas Line (IFGC)](https://gcsradheat.com/tools/gas-pipe-sizing-calculator/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)