title: "Rheem XE40T10H22U1 (3.45 UEF, 36 gal)"
url: https://gcsradheat.com/water-heaters/rheem/xe40t10h22u1/
description: "Certified at 3.45 UEF across its 36-gallon nominal tank, 46 gal First Hour Rating, Rheem XE40T10H22U1 (Hybrid/Electric Heat Pump, Electric) places #563 of 706."
---

ENERGY STAR water heater model · PD 3554171

# Rheem XE40T10H22U1 Water Heater Specifications (3.45 UEF)

Certified at 3.45 UEF across its 36-gallon nominal tank, 46 gal First Hour Rating, Rheem XE40T10H22U1 (Hybrid/Electric Heat Pump, Electric) places #563 of 706 out of 706 ENERGY STAR models (PD 3554171). Its May 6, 2029 10 CFR 430.32 status reads Pass: +1.15 / +50.0%. Rated annual electricity draw of 643 kWh/yr equates to roughly $117/yr ($1,168 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T2 FD400-15 (3.45 UEF).

- **Uniform Energy Factor**: 3.45 UEF

- **Cohort UEF Rank**: #563 of 706

- **First Hour Rating**: 46 gal

- **Storage Volume**: 36 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +1.15 / +50.0%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem XE40T10H22U1 relative to the cohort median.

Efficiency comparison & rule summary

Tested at 3.45 UEF, Rheem XE40T10H22U1 places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.25 UEF vs. 3.70 UEF median).

Rheem XE40T10H22U1 clears 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.15 UEF (+50.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 643 kWh/yr for Rheem XE40T10H22U1 runs ~$117/yr vs. ~$438/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem XE40T10H22U1: 10-year operating spend spans $941 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,034 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Closest alternatives to Rheem XE40T10H22U1 include Friedrich PROH40 T2 FD400-15 (3.45 UEF, at parity) alongside Richmond 10CE40-HP5U15 (3.45 UEF, at parity).

## How Do Rheem XE40T10H22U1 Specs Compare to Hybrid/Electric Heat Pump Medians?

Rheem XE40T10H22U1 places #563 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 3554171 |
| Model Number | XE40T10H22U1 | Draw pattern: Low-Usage | XE40T10H22U1 |
| Uniform Energy Factor (UEF) | 3.45 | -0.25 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 46 gal | -26 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 643 kWh/yr | -429 kWh/yr vs. 1,072 kWh/yr median | Est. $117/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 432% | +3.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 12 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |

## What Does XE40T10H22U1 Cost to Operate Across State Electricity Rates?

At 643 kWh/yr, Rheem XE40T10H22U1 runs roughly $117/yr on the EIA national average tier under August 2026 Table 5.6.A rates.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $117/yr | $1,168 | $3,211 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $303/yr | $3,034 | $8,341 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $191/yr | $1,913 | $5,260 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $102/yr | $1,023 | $2,813 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $94/yr | $941 | $2,587 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (643 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## Are There Active CPSC Safety Recalls for Rheem Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with Rheem; match your serial plate before repair. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## Which Certified Water Heaters Match XE40T10H22U1 Most Closely?

These 5 competing Hybrid/Electric Heat Pump units sit nearest to Rheem XE40T10H22U1 by storage capacity and 3.45 UEF rating.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH40 T2 FD400-15](https://gcsradheat.com/water-heaters/friedrich/proh40-t2-fd400-15/) | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
| [Richmond 10CE40-HP5U15](https://gcsradheat.com/water-heaters/richmond/10ce40-hp5u15/) | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
| [Ruud PROUH40 T2 CD400-15](https://gcsradheat.com/water-heaters/ruud/prouh40-t2-cd400-15/) | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |
| [A. O. Smith CAHP-40 2**](https://gcsradheat.com/water-heaters/a-o-smith/cahp-40-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.15) | 902 |
| [Richmond 10E40-HP5U15](https://gcsradheat.com/water-heaters/richmond/10e40-hp5u15/) | Hybrid/Electric Heat Pump | 36 gal | 46 gal | 3.45 (at parity) | 643 |

## Who Is Rheem XE40T10H22U1 Best For — and When Should You Pick Friedrich PROH40 T2 FD400-15?

Evaluate whether Rheem XE40T10H22U1's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- Rheem XE40T10H22U1 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem XE40T10H22U1 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Rheem XE40T10H22U1** Strong Fit — 3.45 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH40 T2 FD400-15 footprint.

## What Are the Key Questions About Rheem XE40T10H22U1?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Rheem XE40T10H22U1 (3.45 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Rheem XE40T10H22U1 records 3.45 UEF (Pass: +1.15 / +50.0%), placing #563 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does Rheem XE40T10H22U1 fit inside a tight hallway closet or low-headroom utility room?

Rheem XE40T10H22U1 requires room for its 62.3 in. vertical shell and 20.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern Rheem XE40T10H22U1?

For Rheem XE40T10H22U1, plan a 240V circuit at 12A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for Rheem XE40T10H22U1?

Using 643 kWh/yr, Rheem XE40T10H22U1 generates an estimated $117/yr electric bill at 18.16 cents/kWh (ranging from $94/yr in Washington hydro tiers up to $303/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of Rheem XE40T10H22U1 (3.45 UEF)?

Rheem XE40T10H22U1 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH40 T2 FD400-15.

### What hot-water delivery rating governs Rheem XE40T10H22U1?

Rated for 46 gal FHR (-26 gal vs. 72 gal median), Rheem XE40T10H22U1 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen Rheem XE40T10H22U1 for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What alternative models sit closest to Rheem XE40T10H22U1 in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T2 FD400-15 (3.45 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Which Sizing and Compliance Guides Pair with XE40T10H22U1?

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH40 T2 FD400-15 (3.45 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh40-t2-fd400-15/)
- [Compare Richmond 10CE40-HP5U15 (3.45 UEF)→](https://gcsradheat.com/water-heaters/richmond/10ce40-hp5u15/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)