title: "Rheem XE40T10HM00U0 (2.8 UEF, 36 gal)"
url: https://gcsradheat.com/water-heaters/rheem/xe40t10hm00u0/
description: "The Rheem XE40T10HM00U0 (Hybrid/Electric Heat Pump, Electric) achieves a certified 2.8 UEF rating across its 36-gallon nominal tank, 45 gal First Hour Rating."
---

ENERGY STAR water heater model · PD 3555260

# Rheem XE40T10HM00U0 Water Heater Specifications (2.8 UEF)

The Rheem XE40T10HM00U0 (Hybrid/Electric Heat Pump, Electric) achieves a certified 2.8 UEF rating across its 36-gallon nominal tank, 45 gal First Hour Rating, ranking #695 of 706 among 706 ENERGY STAR Hybrid/Electric Heat Pump models (PD 3555260). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.50 / +21.7%. Rated annual electricity draw of 780 kWh/yr equates to roughly $142/yr ($1,416 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Friedrich PROH40 T0 FD120-M (2.8 UEF).

- **Uniform Energy Factor**: 2.8 UEF

- **Cohort UEF Rank**: #695 of 706

- **First Hour Rating**: 45 gal

- **Storage Volume**: 36 gal

- **Fuel / Type**: Electric / Hybrid/Electric Heat Pump

- **DOE 2029 Rule Status**: Pass: +0.50 / +21.7%

Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers

Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Rheem XE40T10HM00U0 relative to the cohort median.

Efficiency comparison & rule summary

Rheem XE40T10HM00U0 (2.8 UEF) ranks #695 of 706 Hybrid/Electric Heat Pump models — 10-way tie; more efficient than 0.3% of Hybrid/Electric Heat Pump models, -0.90 UEF below the 3.70 UEF median.

Federal 2029 margin for Rheem XE40T10HM00U0: +0.50 UEF (+21.7%) vs. 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 780 kWh/yr for Rheem XE40T10HM00U0 runs ~$142/yr vs. ~$431/yr for a 0.92 UEF electric tank.

State electric sensitivity for Rheem XE40T10HM00U0: 10-year operating spend spans $1,141 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $3,680 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Peer comparison: Rheem XE40T10HM00U0 (2.8 UEF) compares closely with Friedrich PROH40 T0 FD120-M (2.8 UEF, at parity) and Richmond 10E40-HP120M (2.8 UEF, at parity).

## Which Specs Set Rheem XE40T10HM00U0 Apart From Cohort Averages?

Ranked #695 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Rheem XE40T10HM00U0 is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers

| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | [Rheem](https://gcsradheat.com/brands/rheem/) | 236 certified listings | ENERGY STAR PD 3555260 |
| Model Number | XE40T10HM00U0 | Draw pattern: Low-Usage | XE40T10HM00U0 |
| Uniform Energy Factor (UEF) | 2.8 | -0.90 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 45 gal | -27 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 780 kWh/yr | -292 kWh/yr vs. 1,072 kWh/yr median | Est. $142/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 387% | -42.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 4.5 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-16 | Certified 2026-10-16 | Markets: United States |

## How Do Regional kWh Prices Impact XE40T10HM00U0 Over 10 Years?

Using EIA Table 5.6.A benchmarks, Rheem XE40T10HM00U0's 780 kWh/yr draw translates to roughly $142/yr on typical US residential bills.

Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.

Estimated electricity cost and 10-year spend across benchmark states

| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| **United States Average** | 18.16 ¢/kWh ($0.1816) | $142/yr | $1,416 | $2,895 |
| [Hawaii (Highest EIA State)](https://gcsradheat.com/states/hawaii/) | 47.18 ¢/kWh ($0.4718) | $368/yr | $3,680 | $7,520 |
| [California](https://gcsradheat.com/states/california/) | 29.75 ¢/kWh ($0.2975) | $232/yr | $2,320 | $4,742 |
| [Texas](https://gcsradheat.com/states/texas/) | 15.91 ¢/kWh ($0.1591) | $124/yr | $1,241 | $2,536 |
| [Washington (Lowest Hydro Tier)](https://gcsradheat.com/states/washington/) | 14.63 ¢/kWh ($0.1463) | $114/yr | $1,141 | $2,332 |

Custom Utility Electricity Rate ($/kWh)

Estimated electricity spend (780 kWh/yr)

Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

## What Should Rheem Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 4 filings tied to Rheem; verify whether your XE40T10HM00U0 production run falls inside affected ranges. See [Serial Number Lookup](https://gcsradheat.com/tools/serial-number-lookup/).

**4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range**

- **Recall #16177 (2016-05-26):** Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot ([CPSC Notice](https://www.cpsc.gov/Recalls/2016/Rheem-Recalls-to-Repair-Water-Heaters))
- **Recall #07108 (2007-02-21):** Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard ([CPSC Notice](https://www.cpsc.gov/Recalls/2007/Tankless-Water-Heaters-Recalled-for-Repair-Due-to-Carbon-Monoxide-Poisoning-Hazard))
- **Recall #05274 (2005-09-16):** CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters ([CPSC Notice](https://www.cpsc.gov/Recalls/2005/CPSC-Robertshaw-Controls-Co-Announce-Recall-of-Gas-Control-Valves-on-Water-Heaters-))
- **Recall #80042 (1980-12-04):** LP Gas Water Heaters Repaired by White-Rodgers ([CPSC Notice](https://www.cpsc.gov/Recalls/1981/Explosion-Hazard-Results-In-Repair-Program-For-600000-LP-Gas-Water-Heaters-Following-Settlement-Of-Penalty-At-420000))

## How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

  5 closest certified peers matched by equipment class, storage volume, and efficiency rating

| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| [Friedrich PROH40 T0 FD120-M](https://gcsradheat.com/water-heaters/friedrich/proh40-t0-fd120-m/) | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
| [Richmond 10E40-HP120M](https://gcsradheat.com/water-heaters/richmond/10e40-hp120m/) | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
| [Ruud PROUH40 T0 RU120-M](https://gcsradheat.com/water-heaters/ruud/prouh40-t0-ru120-m/) | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |
| [A. O. Smith CAHP-40 2**](https://gcsradheat.com/water-heaters/a-o-smith/cahp-40-2/) | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (+0.80) | 902 |
| [Friedrich PROH40 T0 FD120-MSO](https://gcsradheat.com/water-heaters/friedrich/proh40-t0-fd120-mso/) | Hybrid/Electric Heat Pump | 36 gal | 45 gal | 2.8 (at parity) | 780 |

## Who Is Rheem XE40T10HM00U0 Best For — and When Should You Pick Friedrich PROH40 T0 FD120-M?

Evaluate whether Rheem XE40T10HM00U0's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.

### Key Limitations & Exclusions

- Rheem XE40T10HM00U0 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Rheem XE40T10HM00U0 directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.

### Which Option Fits Your Situation?

**High Electric Rate States Choosing Rheem XE40T10HM00U0** Strong Fit — 2.8 UEF trims electric use ~75% vs 0.92 UEF tanks.

**Open Basement or Garage (>=450 cu ft)** Strong Fit — Ample ambient air sustains heat-pump-only efficiency.

**Small Interior Closet (<300 cu ft)** Caution — Add duct kit or compare Friedrich PROH40 T0 FD120-M footprint.

## Frequently Asked Technical Questions: Rheem XE40T10HM00U0

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

### How does Rheem XE40T10HM00U0 (2.8 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Rheem XE40T10HM00U0 records 2.8 UEF (Pass: +0.50 / +21.7%), placing #695 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.

### Does Rheem XE40T10HM00U0 fit inside a tight hallway closet or low-headroom utility room?

Rheem XE40T10HM00U0 requires room for its 62.3 in. vertical shell and 20.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d)), plus service access for annual sediment draining.

### What power supply or fuel line specs govern Rheem XE40T10HM00U0?

For Rheem XE40T10HM00U0, plan a 120V circuit at 4.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery) and keep a dedicated shutoff disconnect within sight of the unit.

### What annual utility bill should homeowners budget for Rheem XE40T10HM00U0?

Using 780 kWh/yr, Rheem XE40T10HM00U0 generates an estimated $142/yr electric bill at 18.16 cents/kWh (ranging from $114/yr in Washington hydro tiers up to $368/yr in Hawaii)—use the custom rate slider above for your utility tariff.

### What are the main drawbacks of Rheem XE40T10HM00U0 (2.8 UEF)?

Rheem XE40T10HM00U0 requires >=450 cu ft air space, 120V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Friedrich PROH40 T0 FD120-M.

### What hot-water delivery rating governs Rheem XE40T10HM00U0?

Rated for 45 gal FHR (-27 gal vs. 72 gal median), Rheem XE40T10HM00U0 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

### Where do homeowners screen Rheem XE40T10HM00U0 for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

### What alternative models sit closest to Rheem XE40T10HM00U0 in the Hybrid/Electric Heat Pump class?

Closest peer in Hybrid/Electric Heat Pump is Friedrich PROH40 T0 FD120-M (2.8 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

## Essential Pre-Install Guides for Rheem XE40T10HM00U0

Explore these verified guides and calculators to check local rules, sizing tables, and licensing steps across TapAndPipe.

- [Compare Friedrich PROH40 T0 FD120-M (2.8 UEF)→](https://gcsradheat.com/water-heaters/friedrich/proh40-t0-fd120-m/)
- [Compare Richmond 10E40-HP120M (2.8 UEF)→](https://gcsradheat.com/water-heaters/richmond/10e40-hp120m/)
- [View All Rheem Water Heater Models & Serial Rules→](https://gcsradheat.com/brands/rheem/)
- [Decode Your Tank Serial Age & Check CPSC Recalls→](https://gcsradheat.com/tools/serial-number-lookup/)
- [Check DOE May 6, 2029 Federal Water Heater Rule→](https://gcsradheat.com/regulations/doe-2029-water-heater-mandate/)

## Sources

1. [ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu)](https://data.energystar.gov/resource/pbpq-swnu.json) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
2. [10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures)](https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-430/subpart-C/section-430.32) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
3. [CPSC SaferProducts.gov Product Recalls REST API](https://www.saferproducts.gov/RestWebServices/Recall?format=json) — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
4. [EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State](https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a) — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Installation checklist

### Before Replacing This Unit

Confirm 240V/120V branch circuit breakers, ceiling headroom, and post-OBBBA state DOE HEAR rebate eligibility up to $1,750 before replacement.
[Check 2026 HPWH Rebates](https://gcsradheat.com/regulations/post-obbba-2026-hpwh-rebates/) [Decode Old Tank Serial](https://gcsradheat.com/tools/serial-number-lookup/)